Wastewater Electromagnetic Flow Meter Rubber Liner Large Meter Ratio

Categories Magnetic Flow Meter
Brand Name: Purescience
Model Number: YF-E150-2
Certification: ISO14001-2000/ISO9001-2008/GB/T28001/MC01010429
Place of Origin: China
MOQ: 5 sets
Price: negotiable
Payment Terms: T/T, L/C, Western Union
Supply Ability: 500 sets per month
Delivery Time: 3 weeks
Packaging Details: carton
Product name: wastewater flow meter
Pressure: PN16
Liner material: NR / CR / PTFE liner
Flow velocity range: 1-15 m/s
Pressure rating: PN16, PN25, PN40 Mpa
Accuracy: +/1 0.5% R
Pipe Dia.: DN25-DN300
Connect port: Flange
Enclosure protection: IP65
Power supply: 100-240 VAC / 18-36 VDC
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Wastewater Electromagnetic Flow Meter Rubber Liner Large Meter Ratio

    Electromagnetic flowmeter for wastewater flow meter in ETP, Rubber liner PN16


    Product Description

    The electromagnetic flow meter, is available with size DN25 - DN1200, it's combined by a flow sensor and transmitter into one convenient package. It incorporates rugged carbon steel construction with flanges creating a versatile, user-friendly flow metering system for general purpose applications involving clean, sanitary, dirty, corrosive and abrasive liquids. The system is IP65 rated for protection from dust and low pressure water jets.


    Features

    • Virtually no pressure loss
    • Suitable to meter for wide range of conductive liquid media
    • No Moving Parts
    • Flanges port connection
    • RS485 Standard
    • Suitable for Pipes diameter p to 2000 mm
    • Large meter ratio
    • High Accuracy
    • 4 to 20 mA / Frequency / Pulse output

    Parameters

    Product name

    Electromagnetic flowmeter

    Product type

    Local|compact display

    Remote display

    Signal converter

    Model

    IYF-E

    IYF-F

    IRT

    Pipe Diameter (mm)

    DN10-DN2000

    Power supply

    100-240 VAC / 18-36 VDC

    Accuracy

    + 0.5%

    + 0.5%

    + 0.5%

    Power consumption

    <6w

    <6w

    <6w

    Enclosure rating

    IP65

    IP68

    IP65

    Liquid temperature

    -25-120℃

    -25-120℃

    -25-120℃

    Ambient temperature

    -25-50℃

    -25-50℃

    -25-50℃

    Relative humidity

    10-90%

    10-90%

    10-90%

    Meter ratio

    1:100

    1:100

    1:100

    Flow direction

    Bi-direction flow

    Bi-direction flow

    Bi-direction flow

    Communication

    RS485 / Bacnet

    RS485 / Bacnet

    RS485 / Bacnet

    Signal Output

    4-20mA/Pulse/Frequency

    4-20mA/Pulse/Frequency

    4-20mA/Pulse/Frequency


    Accuracy

    Pipe Dia (mm)Velocity (m/s)Accuracy
    3-20<0.3+ 0.25% FS
    0.3-1+ 1.0% Readout
    1-15+ 0.25% Readout
    25-6000.1-0.3+ 0.25% FS
    0.3-1+ 0.5% Readout
    1-15+ 0.3% Readout
    700-3000<0.3+ 0.25% FS
    0.3-1+ 1.0% Readout
    1-15+ 0.25% Readout

    Grounding

    From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.


    Model selection


    Applicable metering liquid:

    • Conductive liquid media, conductivity > 5 µS/ cm
    • Various Conductive aqueous solutions, water solutions, acid & caustics
    • Abrasive slurries, sludges and grease bearing liquids, corrosive liquid, municipal tap water, waste water,dirty
      water, effluent, fibrous, viscous, paper mill, food & beverage

    Non-applicable metering medial

    • Industrial gas, compressed air, steam, or liquid with large content of gas
    • Liquid is non-conductive or low conductive, like lubricating oil, clean oil, cryogenic, cooling water, pure
      water, clean gas, etc.

    Notice on the selection of local type and remote type:

    Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select
    remote type in the following conditions:

    • Ambient temperature or converter display sunshine temperature is over 60 ℃
    • High humidity or corrosive air existed
    • Serious pipe vibration
    • Magnetic meter need be suspended or submersible, uneasily read out
    • Other abrasive condition

    I

    Model









    YF

    Electromagnetic flowmeter


    TF

    Turbine


    VF

    Votex


    LX

    Vane wheel


    T

    Ultrasonic



    E/F display mode

    E: compact/local display, F: remote display




    Pipe Dia

    Type (mm)




    xxxx

    15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400,

    500, 600, 800, 1000




    Code

    Accuracy




    1

    + 0.5% FS




    2

    + 1.0% FS




    3

    + 0.2% FS





    Code

    Type





    N

    Converter: 12 / 24 VDC, pulse output





    A

    Transmitter: 24VDC, 4-20mA outpt





    B

    Intelligent, Lion battery, no local display





    G

    Smart, local display, 4-20mA output





    C1

    Smart, local display, RS485





    C2

    Smart, local display, HART






    Code

    Type






    S

    Carbon steel housing






    L

    Stainless steel housing






    G

    High pressure housing






    HL

    316L electrode






    HTi

    Titanium electrode






    HTa

    Tantlum electrode






    HC

    Hastelloy-C electrode






    L1

    Liquid media






    L2

    Gas media






    P

    Pressure compensation






    T

    Temperature compensation






    PT

    Pressure&Temp. Compensation






    F

    PTFE liner






    X

    Rubber liner

    Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing,

    smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner


    Pipe Diameter, flow volume and product dimension

    Dia

    Flow volume (m3/h)

    Product dimension (mm)

    (mm)

    Normal

    Min

    Max

    L

    D

    H

    H1

    15

    1.5

    0.06

    9.5

    150

    95

    272

    254

    20

    2.5

    0.11

    16.9

    105

    277

    254

    25

    3.5

    0.18

    26.5

    115

    283

    254

    32

    6

    0.29

    43.6

    140

    297

    270

    40

    10

    0.45

    67.8

    150

    307

    280

    50

    15

    0.71

    106.0

    200

    165

    318

    294

    65

    25

    1.19

    179.1

    185

    337

    313

    80

    40

    1.81

    271.4

    200

    352

    326

    100

    60

    2.83

    424.1

    250

    220

    371

    344

    125

    100

    4.42

    665

    250

    401

    372

    150

    135

    6.36

    954

    300

    285

    431

    403

    200

    250

    11.3

    1696

    350

    340

    486

    460

    250

    375

    17.66

    2650

    400

    395

    547

    511

    300

    540

    25.43

    3817

    450

    445

    597

    565

    350

    735

    34.62

    5195

    505

    657

    620

    400

    960

    45.22

    6785

    500

    565

    717

    675

    450

    1200

    57.23

    8588

    550

    615

    757

    727

    500

    1500

    70

    10602

    600

    670

    817

    782

    600

    2160

    100

    15268

    780

    917

    782

    700

    2950

    138

    20781

    700

    895

    1027

    1068

    800

    3850

    180

    Buy Wastewater Electromagnetic Flow Meter Rubber Liner Large Meter Ratio at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Shanghai Xunhui Environment Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0