Inside Battery DIN Rail Energy Meter Novel Appearance With Transparent Meter Case

Categories DIN Rail Energy Meter
Brand Name: OEM
Model Number: XTM024-A
Certification: CE ROHS LVD EMC
Place of Origin: ZHEJIANG,CHINA
MOQ: 500pcs
Payment Terms: L/C, T/T, Western Union
Supply Ability: 2000 Piece/Pieces per Week
Delivery Time: 15days
Packaging Details: Inner 1pcs per package ; Carton 30pcs per package
Display Type: LCD
Phase: Three Phase
Output Voltage: 3X220V/380V ; 3X230V/415V
Frequency: 50/60Hz
Accuracy Class: 1.0
Operating Current Range: 5(30)A /10(40)A /15(60)A / 20(80)A / 30(100)A
Communication: RS485 / Modbus-RTU
Measuring Energy Range: 0-999999.9 kWh
Connection mode: 3 Phase 4 Wires
Usage: Active Electric Energy Measurement
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Inside Battery DIN Rail Energy Meter Novel Appearance With Transparent Meter Case

    1. Introduction:


    It is a simple three phase four module Din-Rail meter with transparent meter case, which is widely used in Sub-metering system. This meter is very popular in worldwide for its novel appearance, good quality and reasonable price.


    2. Features and Technical Parameters:


    2.1 Features:

    LCD backlight display.

    Inside battery to support power off display.


    2.2 Technical Parameters:

    Voltage: 3*230/400V

    Current: 3*5(80)A

    Accuracy class: 1.0

    Standard: IEC62052-11, IEC62053-21

    Frequency. 50-60Hz

    Impulse constant: 800imp/kWh

    Display: LCD 6+2

    Power consumption: ≤2W, 10vA

    Starting current: 0.004lb

    Working Temperature: -20~55℃

    Storage Temperature: -25~70℃

    Working voltage: 0.9—1.1 Rated voltage

    Utmost voltage: 0.8--1.15 Rated voltage

    Average humidity value of year: ≤75%

    Creep: Less than 1 impulse when the rated voltage is 115% or current loop without current.


    2.3 Startup:

    The meter can be started and record continuously at the reference current(see the table)

    MeterMeter ClassPower factor
    123
    Direct connect0.04lb0.05lb0.01lb1

    Recommended Wire(For your reference):


    Specification(mm)Norminal cross section(mm2)Safe carrying capacity(A)
    BXBLXBVBLV
    1*1.13120 18 
    1*1.371.525 22 
    1*1.762.533253023
    1*2.24442334030
    1*2.73655425040
    7*1.331080557555
    7*1.76161058010075
    7*2.1225140105130100
    7*2.5035170140160125
    19*1.8350225170205150
    19*2.1475280225255185
    19*2.5095340280320240

    Note: BX(BLX) copper(Aluminum) core rubber insulated wire or BV(BLV) copper (Aluminum) core PVC plastic insulated wire, widely used in 500V or less than 500V AC and DC Power distribution system. The temperature for the data listed in the above table is 35℃,the safe capacity value for the wire on single coved.


    3.Description



    4.Display



    5.Connection Diagram



    6.Meter Dimensions


    Height:100mm

    Width:76mm

    Depth:65mm

    Weight:0.3718kg(Net)


    7.Installation Instruction

    Choose 35mm standard DIN-Rail (the length is confirmed by yourself),fixed them in the location which are waiting for installation;


    Put the meter into the upper DIN-Rail, then push down the clip in the meter bottom, see Fig.1. After the bottom of the meter install into the DIN-Rail successfully, release the clip to make sure the meter have fully installed, see Fig.2 and Fig.3.


    Fig.4 is after installation;

    Making the connection according to the wiring diagram, See Fig.5;



    After connection, use lead sealing to seal terminal cover, see Fig.6



    8. Safety Instructions

    Information for Your Own Safety:

    This manual does not contain all of the safety measures for operation of this equipment(module, device) because special operating conditions, local code requirements or local regulations may necessitate further measures. However, it does contain information which must be adhered to for your own personal safety and to avoid damage to the equipment. This information is highlighted by a warning triangle with an exclamation mark or a lightning bolt depending on the severity of the warning.


    Warning:

    Means that failure to observe the instruction can result in death, serious injury or considerable material damage.


    Caution:

    Means hazard of electric shock and failure to take the necessary safety precautions will result in death, serious injury or considerable material damage.


    Qualified personnel:

    Installation and operation of this equipment described in this manual may only be performed by qualified personal.


    Only people that are authorized to install, connect and use this equipment and have the proper knowledge about labeling and grounding electrical equipment and circuits and can do so according to safety and regulatory standards are considered qualified personnel in the manual.


    Use for the intend purpose:

    The equipment( device, module) may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by WENZHOU MEIHENG ELECTRIC CO.,LTD


    Exclusion of liability:

    We have checked the contents of this publication and every effort has been made to ensure that the descriptions are as accurate as possible. However, deviations from the description cannot be completely ruled out, so that no liability can be accepted for any errors or omissions in the information given. The data in this manual is checked regularly and the necessary corrections will be included in subsequent editions. If you have any suggestions, pls let us know.


    Subject to technical modifications without notice.

    It is prohibited to pass on or copy this document or to use or disclose its contents without our express permission. Any duplication is a violation of the law and subject to criminal and civil penalties. All rights reserved, particularly for pending or approved patents award or registered trademarks.


    General Warning

    After removing the packaging make sure the integrity of the unit. If in doubt don'tuse the equipment and contact technical staff.


    Mounting of electric appliances must be carried out only by skilled electricians. It is imperative to observe the generally applicable safety measures.


    In case of failure and /or malfunctioning of the device, turn off it. For any repair only contact technical staff. Failure to comply with the above may compromise the device safety.


    Warranty.

    The manufactory will repair or exchange the products while the lead seal is still exited, within 18 months, when discovering the products not accordance with the technical specification.


    Technical support

    For any problems of our products please contact:


    Further information:


    1. Plastics materials: all raw materials are brand-new and second-hand materials are forbidden. Furthermore some of them are supplied by super branding companies like DSM, Mitsubishi.


    2. There is just one level of quality as A in MEIHENG and we are aim to provide the excellent articles to our clients and help them gain more market shares.


    3. ODM: we are providing ODM services to the super companies (more than 15) who are top-10 electrical industrial companies in their country. Just show us your ideas and we will present a solution.


    FAQ


    A. How's the delivery time?
    Depend on your quantity, usually within 20days after receiving deposit


    B. Would you accept OEM/ODM service?

    Glad to say that there is planning department, technical department and mould tooling center in

    our factory. For the OEM & ODM, it is ok for us if your brand, market shares are great.


    C. Would you offer free sample?

    Samples are freely provided and shipping costs is paid on your end usually.


    D What's your guaranty time?

    At least 2 years and depend the product


    E What's your payment term?

    T/T, L/C; other terms is negotiable after further check

    Buy Inside Battery DIN Rail Energy Meter Novel Appearance With Transparent Meter Case at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: WENZHOU MEIHENG ELECTRIC CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0