Sign In | Join Free | My benadorassociates.com
benadorassociates.com
Products
Search by Category
Home > Stationery Set >

Original new siemens 6AV2123-2GB03-0AX0 SIMATIC HMI KTP700 BASIC

  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Original new siemens 6AV2123-2GB03-0AX0 SIMATIC HMI KTP700 BASIC


    Thumbnail
    6AV2123-2GB03-0AX0
    SIMATIC HMI KTP700 BASIC
    SIMATIC HMI, KTP700 BASIC, BASIC PANEL, KEY AND TOUCH OPERATION, 7" TFT DISPLAY, 65536 COLORS, PROFINET INTERFACE, CONFIGURATION FROM WINCC BASIC V13/ STEP7 BASIC V13, CONTAINS OPEN SOURCE SW WHICH IS PROVIDED FREE OF CHARGE FOR DETAILS SEE CD

    Technical data

    SIMATIC HMI, KTP700 BASIC, BASIC PANEL, KEY AND TOUCH OPERATION, 7" TFT DISPLAY, 65536 COLORS, PROFINET INTERFACE, CONFIGURATION FROM WINCC BASIC V13/ STEP7 BASIC V13, CONTAINS OPEN SOURCE SW WHICH IS PROVIDED FREE OF CHARGE FOR DETAILS SEE CD
    General information
    Product type designationKTP700 Basic color PN
    Display
    Design of displayTFT widescreen display, LED backlighting
    Screen diagonal7 in
    Display width154.1 mm
    Display height85.9 mm
    Number of colors65 536
    Resolution (pixels)
    ● Horizontal image resolution800 Pixel
    ● Vertical image resolution480 Pixel
    Backlighting
    ● MTBF backlighting (at 25 °C)20 000 h
    ● Backlight dimmableYes
    Control elements
    Keyboard fonts
    ● Function keys
    — Number of function keys8
    ● Keys with LEDNo
    ● System keysNo
    ● Numeric keyboardYes; Onscreen keyboard
    ● alphanumeric keyboardYes; Onscreen keyboard
    Touch operation
    ● Design as touch screenYes
    Installation type/mounting
    Mounting positionHorizontal, vertical
    Mounting in portrait format possibleYes
    Mounting in landscape format possibleYes
    maximum permissible angle of inclination without external ventilation35°
    Supply voltage
    Type of supply voltageDC
    Rated value (DC)24 V
    permissible range, lower limit (DC)19.2 V
    permissible range, upper limit (DC)28.8 V
    Input current
    Current consumption (rated value)230 mA
    Starting current inrush I²t0.2 A²·s
    Power
    Active power input, typ.5.5 W
    Processor
    Processor typeARM
    Memory
    FlashYes
    RAMYes
    Memory available for user data10 Mbyte
    Type of output
    Acoustics
    ● BuzzerYes
    ● SpeakerNo
    Time of day
    Clock
    ● Hardware clock (real-time)Yes
    ● Software clockYes
    ● retentiveYes; Back-up duration typically 6 weeks
    ● synchronizableYes
    Interfaces
    Number of industrial Ethernet interfaces1
    Number of RS 485 interfaces0
    Number of RS 422 interfaces0
    Number of RS 232 interfaces0
    Number of USB interfaces1; Up to 16 GB
    Number of 20 mA interfaces (TTY)0
    Number of parallel interfaces0
    Number of other interfaces0
    Number of SD card slots0
    With software interfacesNo
    Industrial Ethernet
    ● Industrial Ethernet status LED2
    Protocols
    PROFINETYes
    Supports protocol for PROFINET IONo
    IRTNo
    MRPNo
    PROFIBUSNo
    MPINo
    Protocols (Ethernet)
    ● TCP/IPYes
    ● DHCPYes
    ● SNMPYes
    ● DCPYes
    ● LLDPYes
    WEB characteristics
    ● HTTPNo
    ● HTMLNo
    Further protocols
    ● CANNo
    ● EtherNet/IPYes
    ● MODBUSYes; Modicon (MODBUS TCP/IP)
    Interrupts/diagnostics/status information
    Diagnostic messages
    ● Diagnostic information readableNo
    EMC
    Emission of radio interference acc. to EN 55 011
    ● Limit class A, for use in industrial areasYes
    ● Limit class B, for use in residential areasNo
    Degree and class of protection
    IP (at the front)IP65
    Enclosure Type 4 at the frontYes
    Enclosure Type 4x at the frontYes
    IP (rear)IP20
    Standards, approvals, certificates
    CE markYes
    cULusYes
    RCM (formerly C-TICK)Yes
    KC approvalYes
    Marine approval
    ● Germanischer Lloyd (GL)Yes
    ● American Bureau of Shipping (ABS)Yes
    ● Bureau Veritas (BV)Yes
    ● Det Norske Veritas (DNV)Yes
    ● Lloyds Register of Shipping (LRS)Yes
    ● Nippon Kaiji Kyokai (Class NK)Yes
    ● Polski Rejestr Statkow (PRS)No
    ● Chinese Classification Society (CCS)No
    Use in hazardous areas
    ● ATEX Zone 2No
    ● ATEX Zone 22No
    ● IECEx Zone 2No
    ● IECEx Zone 22No
    ● cULus Class I Zone 1No
    ● cULus Class I Zone 2, Division 2No
    ● FM Class I Division 2No
    Ambient conditions
    Ambient temperature during operation
    ● Operation (vertical installation)
    — For vertical installation, min.0 °C
    — For vertical installation, max.50 °C
    ● Operation (max. tilt angle)
    — At maximum tilt angle, min.0 °C
    — At maximum tilt angle, min.40 °C
    ● Operation (vertical installation, portrait format)
    — For vertical installation, min.0 °C
    — For vertical installation, max.40 °C
    ● Operation (max. tilt angle, portrait format)
    — At maximum tilt angle, min.0 °C
    — At maximum tilt angle, min.35 °C
    Ambient temperature during storage/transportation
    ● min.-20 °C
    ● max.60 °C
    Relative humidity
    ● Operation, max.90 %; no condensation
    Operating systems
    proprietaryYes
    pre-installed operating system
    ● Windows CENo
    Configuration
    Message indicatorYes
    Alarm system (incl. buffer and acknowledgment)Yes
    Process value display (output)Yes
    Process value default (input) possibleYes
    Recipe managementYes
    Configuration software
    ● STEP 7 Basic (TIA Portal)Yes; via integrated WinCC Basic (TIA Portal)
    ● STEP 7 Professional (TIA Portal)Yes; via integrated WinCC Basic (TIA Portal)
    ● WinCC flexible CompactNo
    ● WinCC flexible StandardNo
    ● WinCC flexible AdvancedNo
    ● WinCC Basic (TIA Portal)Yes
    ● WinCC Comfort (TIA Portal)Yes
    ● WinCC Advanced (TIA Portal)Yes
    ● WinCC Professional (TIA Portal)Yes
    Languages
    Online languages
    ● Number of online/runtime languages10
    Project languages
    ● Languages per project32
    Functionality under WinCC (TIA Portal)
    LibrariesYes
    Applications/options
    ● Web browserYes
    ● SIMATIC WinCC Sm@rtServerYes; Available with WinCC (TIA Portal) V14 or higher
    Number of Visual Basic ScriptsNo
    Task plannerYes
    ● time-controlledNo
    ● task-controlledYes
    Help systemYes
    ● Number of characters per info text500
    Message system
    ● Number of alarm classes32
    ● Bit messages
    — Number of bit messages1 000
    ● Analog messages
    — Number of analog messages25
    ● S7 alarm number procedureNo
    ● System messages HMIYes
    ● System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.)Yes; System message buffer of the SIMATIC S7-1200 and S7-1500
    ● Number of characters per message80
    ● Number of process values per message8
    ● Acknowledgment groupsYes
    ● Message indicatorYes
    ● Message buffer
    — Number of entries256
    — Circulating bufferYes
    — retentiveYes
    — maintenance-freeYes
    Recipe management
    ● Number of recipes50
    ● Data records per recipe100
    ● Entries per data record100
    ● Size of internal recipe memory256 kbyte
    ● Recipe memory expandableNo
    Variables
    ● Number of variables per device800
    ● Number of variables per screen100
    ● Limit valuesYes
    ● MultiplexingYes
    ● StructuresNo
    ● ArraysYes
    Images
    ● Number of configurable images250
    ● Permanent window/defaultYes
    ● Global imageYes
    ● Pop-up imagesNo
    ● Slide-in imagesNo
    ● Image selection by PLCYes
    ● Image number in the PLCYes
    Image objects
    ● Number of objects per image100
    ● Text fieldsYes
    ● I/O fieldsYes
    ● Graphic I/O fields (graphics list)Yes
    ● Symbolic I/O fields (text list)Yes
    ● Date/time fieldsYes
    ● SwitchesYes
    ● ButtonsYes
    ● Graphic displayYes
    ● IconsYes
    ● Geometric objectsYes
    Complex image objects
    ● Number of complex objects per screen10
    ● Alarm viewYes
    ● Trend viewYes
    ● User viewYes
    ● Status/controlNo
    ● Sm@rtClient viewNo
    ● Recipe viewYes
    ● f(x) trend viewNo
    ● System diagnostics viewYes; System message buffer of the SIMATIC S7-1200 and S7-1500
    ● Media PlayerNo
    ● HTML browserYes
    ● PDF displayNo
    ● IP camera displayNo
    ● Bar graphsYes
    ● SlidersNo
    ● Pointer instrumentsNo
    ● Analog/digital clockNo
    Lists
    ● Number of text lists per project300
    ● Number of entries per text list100
    ● Number of graphics lists per project100
    ● Number of entries per graphics list100
    Archiving
    ● Number of archives per device2; One message and one process value archive
    ● Number of entries per archive10 000
    ● Message archiveYes
    ● Process value archiveYes
    ● Archiving methods
    — Sequential archiveYes
    — Short-term archiveYes
    ● Memory location
    — Memory cardNo
    — USB memoryYes
    — EthernetNo
    ● Data storage format
    — CSVNo
    — TXTYes
    — RDBNo
    Security
    ● Number of user groups50
    ● Number of user rights32
    ● Number of users50
    ● Password export/importYes
    ● SIMATIC LogonNo
    Character sets
    ● Keyboard fonts
    — US EnglishYes
    Transfer (upload/download)
    ● MPI/PROFIBUS DPNo
    ● USBNo
    ● EthernetYes
    ● using external storage mediumYes
    Process coupling
    ● S7-1200Yes
    ● S7-1500Yes
    ● S7-200Yes
    ● S7-300/400Yes
    ● LOGO!Yes
    ● WinACYes
    ● SINUMERIKYes; No access to NCK data
    ● SIMOTIONYes
    ● Allen Bradley (EtherNet/IP)Yes
    ● Allen Bradley (DF1)No
    ● Mitsubishi (MC TCP/IP)Yes
    ● Mitsubishi (FX)No
    ● OMRON (FINS TCP)No
    ● OMRON (LINK/Multilink)No
    ● Modicon (Modbus TCP/IP)Yes
    ● Modicon (Modbus)No
    Service tools/configuration aids
    ● Backup/Restore manuallyYes
    ● Backup/Restore automaticallyNo
    ● SimulationYes
    ● Device switchoverYes
    Peripherals/Options
    Peripherals
    ● PrinterNo
    ● SIMATIC HMI MM memory card: Multi Media CardNo
    ● SIMATIC HMI SD memory card: Secure Digital memory cardNo
    ● SIMATIC HMI CF memory card Compact Flash CardNo
    ● USB memoryYes
    ● SIMATIC IPC USB Flashdrive (USB stick)Yes
    ● SIMATIC HMI USB stickYes
    Mechanics/material
    Enclosure material (front)
    ● PlasticYes
    ● AluminumNo
    ● Stainless steelNo
    Dimensions
    Width of the housing front214 mm
    Height of housing front158 mm
    Mounting cutout, width197 mm
    Mounting cutout, height141 mm
    Overall depth39 mm
    Weights
    Weight without packaging780 g
    Weight incl. packaging990 g
    last modified:10/26/2017
    Buy Original new siemens 6AV2123-2GB03-0AX0  SIMATIC HMI KTP700 BASIC at wholesale prices
    Send your message to this supplier
     
    From:
    To: XIN YAN INDUSTRIAL LIMITED
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0