Solar Radiation Quv Accelerated Aging Test Chamber / Uv Testing Machine

Categories UV Weathering Test Chamber
Brand Name: OTS
Model Number: XB-OTS-UVA/B
Certification: CE Certification
Place of Origin: China
MOQ: one set
Price: Negotiable
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100 Unit/Units per Month
Delivery Time: 20 working day after getting the payment
Packaging Details: Strong standard wood case, inner plastic films wrapped for UVA UVB Light Fastness Aging Test Chamber , UV Accelerated Weathering Tester
Model Numbe: XB-OTS-UVA/B
Product name: UVA UVB Light Fastness Aging Test Chamber , UV Accelerated Weathering Tester
UV Wavelength: 320-400um(UV-a), 280-320um(UV-B)
Lamp Power: 40W/Unit, 8PCS for Unit Chamber
Size Of Standard Specimen: 75×150mm (customized Available)
Distance Between Lamps: 70mm
Usage: UV aging test chamber
Material: Stainless Steel
Internal size: 130*146*50cm
FOB Port: Shenzhen
Warranty: 15 months
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Solar Radiation Quv Accelerated Aging Test Chamber / Uv Testing Machine

    UVA UVB Light Fastness Aging Test Chamber , UV Accelerated Weathering Tester


    Product description:


    Accelerated Weather UV test machine is applicable for the sunlight resistant test of nonmetallic materials and aging test of artificial light sources. A variety of industrial products can make the reliability test, and this product can simulate the product in the sun, rain, humidity and dew conditions, including damage caused by bleaching, color, brightness down, powder, crack, blur, brittle, intensity decreased and oxidation.


    Chamber Structure:


    The inner bladder of the chamber is made of imported high-class stainless steel plate while the outer bladder is made of SUS 304 steel plate.

    The heating mode adopts inner bladder trough type heating with its rapid temperature rise and even temperature distribution.


    Technical parameters: Various Material UV Lamp Weatherometer


    Studio Size400W×1140D×390Hmm
    Outside dimension500W×1300D×1360Hmm
    MaterialsInside and Outside SUS#304 stainless steel
    Temperature rangeRT+10~70°C
    Temperature uniformity±2°C
    Temperature fluctuation±0.5°C
    Temperature controlPID SSR control
    Humidity range:≥90%RH
    ControllerKorean TEMI 880 programmable controller
    Control modeBalance temperature humidity control (BTHC)
    Test cycle settingIllumination, condensation and water spray test cycle is programmable
    Lamp power40W/Piece
    Distance from sample to lamp50±2mm (adjustable)
    Centre distance between the lamp70mm
    Irradiance1.0W/cm2
    Wavelength ultraviolet lightUV-A: 315-400nm; UV-B: 280-315nm (8pcs, 1600h lifetime)
    Effective irradiation areas640×1140mm
    Irradiation black panel temperature50°C~70°C
    Standard Specimen Size75×150mm or 75×3000mm (special specitications to be described in the contact)
    Required water depth for water channel25mm, automatically control
    Testing time0~999H, adjustable
    Power220V/50Hz /±10% 5KW
    Protection systemOverload short circuit protection, over temperature protection, water lackin

    Control System:


    Adopts black aluminum plate to connect temperature sensor and adopts black board temperature meter to control heating so as to

    ensure more stable temperature.
    The radiometer probe is fixed so as to avoid the frequent installation and disassembly.
    The illumination and condensation can be controlled independently or alternating and circularly.


    Design criteria:


    (1) ASTM D4587: Standard Practice for Fluorescent UVCondensation Exposures of Paint and Related Coatings

    (2) ASTM D4799: Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials

    (Fluorescent UV, Water Spray, and Condensation Method)

    (3) ISO 4892-1: Plastics – Methods of Exposure to Laboratory Light Sources – Part 1: General guidance

    (4) ISO 4892-3: Plastics - Methods of Exposure to Laboratory Light Sources - Part 3: Fluorescent UV Lamps

    (5) ASTM D4329: Standard Practice for Fluorescent UV Exposure of Plastics

    (6) AATCC TM186: Weather Resistance: UV Light and Moisture Exposure

    (7) ASTM D5208: Standard Practice for Fluorescent Ultraviolet (UV) Exposure of Photodegradable Plastics

    (8) IEC 61345: UV Test for Photovaltalic (PV) Modules


    Feature :


    * Our UV aging test chamber series includes 4 different types of UV aging test boxes, QUV/se, QUV/basci, QUV/spray and QUV/cw. It can meet the testing standards of coatings, ink, adhesives, plastic products and other industries.

    • Different test methods and procedures: Automatic control, real-time monitoring and display.
    • The sample frame temperature: Sample temperature BPT directly display and automatic control.
    • Condensation control: Condensation directly display and automatic control.
    • Circular manner: Light, condensation and spray directly display and automatic control.
    • Light irradiance: Testing process can be set light irradiance energy and time and monitoring.
    • Spray water: Adjustable and display, automatic control, test process can be set spraying time.
    • The calibration function: Automatic temperature calibration, convenient, fast.
    • Alarm function: Automatic alarm .
    • Water supply way: Automatic feed water.
    • PC connection method : RS232

    Standard:


    1. ISO 48-3-2006, Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps;
    2. ASTM D4329-2005, Standard Practice for Fluorescent UV Exposure of Plastics;
    3. ASTM D4587-2005, Standard Practice for Fluorescent UV-Condensation Exposures of Paint and Related Coatings;
    4. ASTM D5208-2001, Standard Practice for Fluorescent Ultraviolet (UV) Exposure of Photodegradable Plastics, etc.


    Please feel FREE to contact us if you have any needs.

    UVA UVB Light Fastness Aging Test Chamber , UV Accelerated Weathering Tester

    Buy Solar Radiation Quv Accelerated Aging Test Chamber / Uv Testing Machine at wholesale prices
    Send your message to this supplier
     
    *From:
    *To: Dongguan Xinbao Instrument Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0