Place of Origin: Sichuan, China (Mainland)
Brand Name: Vacorda
Model Number: HKLD
Supply Ability: 100 Piece/Pieces per Week
Packaging Details: Wooden box.
MOQ: 1 Piece/Pieces
Price: US300/piece
Certification: CE/ISO9001
Certificate: ISO9001:2000
Aftersell service: 12 months
Material: 316L
measuring range: 50Pa~10MPa
Signal output: 4~20mA
transmission distance: above 1000m
working voltage: 12~45V DC
weight: about 3.5KG
application: oil, pollution water, diesel fuel, chemical industry
Name: Magnetic flow meter
Port: Shanghai/Shenzhen
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    316S Stainless Steel Electromagnetic Flow Meter Hydrology Open Channel Electromagnetic Flow Meter

    316S Stainless Steel Electromagnetic Flow Meter Hydrology Open Channel Electromagnetic Flow Meter


    Electromagnetic flowmeter as an effectively measure the volume flow rate of conductive media, its main components include sensors, flow conversion and processing instruments. And its main feature is that it has no throttling flow-resisting parts, it is not easy to block, has good corrosion resistance, and has a wide range of applicable media. The measurement accuracy is not affected by physical parameters such as temperature, viscosity, density, pressure, and specific gravity of the measured medium. A certain conductivity range is independent of the type of liquid being calibrated.

    As a most widely used flow instrument, electromagnetic flowmeters are commonly used to measure conductive liquids such as tap water, sewage, and seawater. Therefore, after running for a period of time, it is easy to contaminate the electrode or to precipitate and foul in the measurement tube wall. So the adhered scale layer in the measuring tube of the electromagnetic flowmeter should be removed in time, otherwise the instrument may not work properly.


    Application

    Due to its unique advantages, it is widely used in the fields of petroleum, chemical industry, steel, light industry, sewage processing, environmental protection, water conservancy project and pharmacy to measure the volume flow of the conducted liquid mediums, such as acid, alkali, salt solution and so on.


    Features:

    1. No moving and blocked flow parts in the pipeline, almost no additional pressure loss in the measurement.

    2. Measurements results are independent of physical parameters, such as flow distribution, fluid pressure, temperature, density and viscosity.

    3. On-site modification of the measuring range available.

    4. LCD display, easy to use and simple to operate.

    5. Using SMD devices and SMT technology.

    6. Using 16-bit embedded processors with fast speed and high accuracy, enhancing the stability of measurement.

    7. Anti-interference, reliability, measurement range up to 150:1.

    8. Ultra low EMI switch, wide range of power supply voltage.

    9. RS485, RS232, Hart and Modbus digital communication signal output.

    10. Self-checking function.


    Technical parameters

    PTFE Lined Pipe

    10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600

    Rubber Lined Pipe

    40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400, 500, 600, 800, 1000, 1200, note: special specifications can be customized

    Flow direction

    positive and negative, net flows Turndown

    Measuring range ratio

    150:1

    Repeatability error

    +/-0.1%

    Accuracy

    piped: 0.5 class, 1.0 class

    Measured medium temperature

    Common rubber lining: -20~+60 ° c

    High temperature rubber lining: -20~+90 ° c

    PTFE lining: -30~+100 ° c

    High temperature vinyl lining: -30~+180 ° c

    Rated working pressure

    pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa;

    DN200~DN1200: ≤ 1.0MPa

    Flow measuring range

    flow measuring range corresponding to flow rate range is 0.3~15m/s

    Measured fluid conductivity

    5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow)

    Output

    Current:4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA

    Load resistance

    < 600 Ω

    Electrode material

    316L, titanium (Ti), tantalum (Ta), Hastelloy, (h), Platinum (Pt) or other special electrode materials

    Protection grade

    standard: IP65; IP68

    Working power supply

    85~265VAC 45~63HZ

    Straight pipe length

    pipe: ≥ 5DN in the upper reaches, downstream of greater than or equal to 2DN

    Connections

    flow meter connected to the piping is used between flanges, flange connection dimensions comply with GB9119-88 requirements.

    Explosion-proof mark

    mdllBT4

    environment temperature

    -25 ° c ~=60 ° c

    Relative humidity

    5%~95%

    Total power consumption

    <20W

    Buy 316S Stainless Steel Electromagnetic Flow Meter Hydrology Open Channel Electromagnetic Flow Meter at wholesale prices