| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Ultrasonic Flow Meters | 
|---|---|
| Brand Name: | Purescience | 
| Model Number: | IT3-1 | 
| Certification: | ISO4064-1 / GBT778-2007 / JJG162-2009 | 
| Place of Origin: | China | 
| MOQ: | 5 pieces | 
| Price: | USD300 - USD 800 / set | 
| Payment Terms: | L/C, T/T, D/P | 
| Supply Ability: | 10000 pieces per month | 
| Delivery Time: | 3-6 weeks | 
| Packaging Details: | carton | 
| Principle: | Transit time | 
| Accuracy: | + / - 1%FS | 
| Liquid media temp.: | 0.1 - 30 ℃ (media), -10 - 45 ℃ (Ambient) | 
| Operation pressure: | 1.6 Mpa, 2.5 Mpa as option | 
| Upstream sensor: | U3 | 
| Downstream sensitivity: | D0 | 
| Climatic and mechanical: | C class | 
| Electromagnetic compatibility: | E2 class | 
| Communication: | RS485 / USART / Infrared | 
| Output signal: | 2-way OCT pulse / TTL pulse / 1-way 4-20mA | 
Bi-directional ultrasonic water meter for instantaneous flow and accumulative water flow DN50 Cast
Iron | CI
Description:
The new type Ultrasonic water meter are with built in batch controller and time accumulator. It has extremely low power consumption, stable and reliable performance in long term. All the wet part protection is IP68. The UFM is widely used in municipal water supply, water resource management, industrial water supply, agriculture, irrigation and gardening.
Features
Parameters
Liquid media: water, sewage, seawater, effulent, municipal tap water, etc.
Work temperature: 0.1 - 30℃
Environment termpreature: -10 - 45℃
Humidity: <100% RH
Operate pressure: 1.6 Mpa / 2.5 Mpa
Upstream sensitivity: U3
Down stream sensitivity: D0
Climatic and mechanical: class C
EMC compativility class: class E2
Communication: RS485 / USART / Infrared
Signal output: Dual way OCT pulse / TTL pulse / single way 4-20mA
Power supply: lithium battery, 3.6V / 19Ah or DC8-36V
Protection: IP68
Digital display Multi line 9 digital accumulated flow, 4 digital instant flow
Data storage: EEPROME / Flash, last 512 days accumulative flow
Measuring cycle: every second, Verification: 4 times / second
Standard: ISO4064, GBT 778-2007
Product overview

Display and operation

Communication and signal output
| RS485 | OCT1 (open collector output 1) | 
| M-BUS | OCT2 (open collector output 2) | 
| DC8-36V | C1 (TTL level pulse output 1) | 
| Two-way 4-20mA output | C2 (TTL level pulse output 2) | 
Material
DN15-DN40 Single channel ultrasonic water meter (copper)
DN50-DN40 Dual channel bulk ultrasonic water meter (cast iron)
DN200-DN300 Dual channel large ultrasonic water meter (welded carbon steel)
Flow range
| Nominal D | R | Flow (m3/h) | ||||
| Starting flow | Minimal flow (Q1) | Transitional flow (Q2) | Normal flow (Q3) | Overload flow (Q4) | ||
| DN15 | 200 | 0.003 | 0.0125 | 0.020 | 2.500 | 3.125 | 
| DN20 | 200 | 0.0035 | 0.016 | 0.026 | 3.200 | 4.000 | 
| DN25 | 200 | 0.007 | 0.020 | 0.032 | 4.000 | 5.000 | 
| DN32 | 200 | 0.010 | 0.032 | 0.050 | 6.300 | 7.875 | 
| DN40 | 200 | 0.015 | 0.100 | 0.160 | 20.000 | 25.000 | 
| DN50 | 100 | 0.030 | 0.400 | 0.640 | 40.000 | 50.000 | 
| DN65 | 100 | 0.059 | 0.630 | 1.008 | 63.000 | 78.750 | 
| DN80 | 100 | 0.064 | 1.000 | 1.600 | 100.000 | 125.000 | 
| DN100 | 100 | 0.094 | 1.600 | 2.560 | 160.000 | 200.000 | 
| DN125 | 100 | 0.120 | 2.000 | 3.200 | 200.000 | 250.000 | 
| DN150 | 100 | 0.270 | 2.500 | 4.000 | 250.000 | 312.500 | 
| DN200 | 100 | 0.315 | 4.000 | 6.400 | 400.00 | 500.00 | 
| DN250 | 100 | 0.508 | 4.000 | 6.400 | 400.00 | 500.00 | 
| DN300 | 100 | 0.770 | 6.300 | 10.080 | 630.00 | 787.500 | 
Competitive Advantage:
Production line


Calibration equipment

|   | 
 Doppler Fixed Clamp On Ultrasonic Flow Meters By Sound Wave To Determine Velocity Of Waste Water
                                                                                    
                        
                        
                        
                                                            Doppler Fixed Clamp On Ultrasonic Flow Meters By Sound Wave To Determine Velocity Of Waste Water
                                                    
                        
                     Transit Time Fixed Insertion Ultrasonic Magnetic Flow Meter For Slurry / Sewage
                                                                                    
                        
                        
                        
                                                            Transit Time Fixed Insertion Ultrasonic Magnetic Flow Meter For Slurry / Sewage
                                                    
                        
                     Open Channel Ultrasonic Magnetic Flow Meter For Sewage / Waste Water Treatment 600 m3 / H Converter
                                                                                    
                        
                        
                        
                                                            Open Channel Ultrasonic Magnetic Flow Meter For Sewage / Waste Water Treatment 600 m3 / H Converter
                                                    
                        
                     10m/S 40mm PN16 RS485 Ultrasonic Water Meter Brass Pipe
                                                                                    
                        
                        
                        
                                                            10m/S 40mm PN16 RS485 Ultrasonic Water Meter Brass Pipe
                                                    
                        
                     Insert doppler Ultrasonic Flow meter for volume flow measurement
                                                                                    
                        
                        
                        
                                                            Insert doppler Ultrasonic Flow meter for volume flow measurement
                                                    
                        
                     Residential Water Ultrasonic Flow Meters Convectional Type Pn16 Pressure
                                                                                    
                        
                        
                        
                                                            Residential Water Ultrasonic Flow Meters Convectional Type Pn16 Pressure
                                                    
                        
                     Portable Ulstrasonic Magnetic Flow Meter For Volumetric Measurement Non Contact Corrosion Resistance
                                                                                    
                        
                        
                        
                                                            Portable Ulstrasonic Magnetic Flow Meter For Volumetric Measurement Non Contact Corrosion Resistance
                                                    
                        
                     Residential Inline Ultrasonic Flow Meters LCD Irrigation Mass Flow Measurement
                                                                                    
                        
                        
                        
                                                            Residential Inline Ultrasonic Flow Meters LCD Irrigation Mass Flow Measurement
                                                    
                        
                     GPRS Wireless Ultrasonic Water Meter , Convectional Type DN25 Brass Tube R500
                                                                                    
                        
                        
                        
                                                            GPRS Wireless Ultrasonic Water Meter , Convectional Type DN25 Brass Tube R500
                                                    
                        
                     Irrigation DN50 PN16 Strap On Ultrasonic Flow Meters
                                                                                    
                        
                        
                        
                                                            Irrigation DN50 PN16 Strap On Ultrasonic Flow Meters