Operating Voltage: | 120-277Vac, 50/60Hz |
Product Name: | microwave motion sensor |
Function: | 2 step /3 step dimming/on off function |
IP Rating: | IP20 |
Rated load: | 400W@120Vac(Ballast) ,1000W@277Vac(Ballast) 800W@120Vac(Resistive),1000W@277Vac(Resistive) |
HF system: | 5.8GHz ±75MHz, ISM wave band |
Size: | 3.68'' x 1.77'' x 1.12'' |
Detection Area: | 8m Max. |
Company Info. |
Shenzhen Merrytek Technology Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
UL Certification Dimming Function Microwave Motion MC601V With 0-10V Button for North America
Description
The MC601V is innovative and active motion detectors with HF system 5.8GHz. Motion can be detected through plastic, glass and thin non-metal materials. And it's suitable for North America with UL certification.
It is enhanced detection zone sensor, As it uses the third generation Merrytek technology, normal 5.8GHz microwave module can easily reach high mounting high up to 12m and long detection area 8m in radius. And there are two different installation way, surface mounting and based on mounting,
The sensors allow energy saving without compromising comfort. When used in combination with 0-10V dimmable LED drivers or ballasts, they can achieve 3-step dimming function, which is perfect for use in some areas that requires a light change notice before totally switch off.
Also, the 0-10V interface in the sensors can match up with Merrytek stand-alone daylight sensor MS01, and implement daylight harvesting, means the lighting system has automated controls that either turn off or dim artificial light in response to the available daylight in the space.
Feature
1. Input voltage 120/277V AC, 50-60Hz
2. 2-step or 3 step dimming with 1-10V dimmable led driver
3. Designed with Syn interface,a group of sensors can be controlled synchronously
4. 5 years warranty
Parameters
Input | Operating voltage | 108-305V AC 50Hz/60Hz |
Rated voltage | 120-277V AC 50Hz/60Hz | |
Stand-by power | ≤1.0W | |
Surge test | N—L: 1kV | |
Output | Working mode | ON/OFF 1-10V dimming |
Type of load | Inductive or resistive | |
Load capacity | AC 120V 400W, AC220V-240V 800W, AC 277V 1000W | |
Max.surge capacity | 50A (50% Ipeak, twidth =500uS, 277Vac full load, cold start); 80A (50% Ipeak, twidth =200uS, 277Vac, full load, cold start) | |
Dim interface | 1-10V Dimming | < 50mA(Non-constant source) |
Syn control | 0/5V | |
Sensor parameters | Operating frequency | 5.8 GHz ±75 MHz,ISM band |
Transmitting power | 0.5mW Max. | |
Hold time | 5s/30s/90s/3min/20min/+∞ | |
Stand-by dim Level | 10%/20%/30%/50% | |
Stand-by Period | 0S/5S/5min/10min/30min/1h/+∞ | |
Detection Area | 25%/50%/75%/100%/ | |
Daylight Sensor | 2 lux/5Lux /10Lux 25Lux /50Lux /100Lux /Disable | |
Detection Pattern | Refer to detection pattern | |
Mounting height | Suggest:3-10m support 12m Max. | |
Detecting Angle | 150°(wall mounting) 360°(ceiling mounting) | |
Operating envrionment | Operating Temperature | -30℃~60℃ |
Storage Temperature/humidity | -40℃~80℃ | |
Certificate Standards | Safety standards | EN61058-1,EN61058-1-2,UL60730 |
EMC standards | EN55015,EN61547,EN6100,EN301489,EN300440 | |
Environmental Requirement | Compliant to RoHS | |
Certificate | CE, RED, cULus | |
Others | Wiring | Press-in terminals wire diamter:0.75-1.5mm2 |
IP Rating | IP20 | |
Protection Class | Class II | |
Installation | Built-in | |
Installation imension | 180*50*30mm | |
Package | Bubble bag+ Clapboard+ Carton(K=A) | |
Net weight | 75g | |
Life time | 5 years warranty @Ta 230V full load | |
Note 1. “N/A”means not available. 2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s |
Function
1. On-off function(Stand-by Period “0s”)
2. 2-step dimming function(Stand-by Period“+∞”)
3. 3-step dimming function(Stand-by Period“5s/5min/10min/30min/1h”)
Dimension (mm)
*To aviod blocking microwave transmitting, please cut hole as image above to make sure microave antenna exposed froom any metal.
Wiring
*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.
Structure
Detection pattern
Ceiling mounting
Height:3m | Height:6m | Height:9m | Height:12m |
Sensitivity:100% | Sensitivity:100% | Sensitivity:100%/75% | Sensitivity:100% |
Fast moving | Fast moving | Fast moving | Fast moving |
(Speed: 1m/s) | (Speed: 1m/s) | (Speed: 1m/s) | (Speed: 1m/s) |
Slow moving | Slow moving | Slow moving | Slow moving |
(Speed: 0.3m/s) | (Speed: 0.3m/s) | (Speed: 0.3m/s) | (Speed: 0.3m/s) |
Dip switch settings
Detection Area
1 | 2 | ||
Ⅰ | ON | ON | 100% |
Ⅱ | ON | - | 75% |
Ⅲ | - | ON | 50% |
Ⅳ | - | - | 10% |
Hold Time
3 | 4 | 5 | ||
Ⅰ | ON | ON | ON | 5S |
Ⅱ | - | ON | ON | 30S |
Ⅲ | ON | - | ON | 90S |
Ⅳ | - | - | ON | 3min |
Ⅴ | ON | ON | - | 20min |
Ⅵ | -5 | - | - | +∞ |
Stand-by Period
6 | 7 | 8 | ||
Ⅰ | ON | ON | ON | 0S |
Ⅱ | - | ON | ON | 5S |
Ⅲ | ON | - | ON | 5min |
Ⅳ | - | - | ON | 10min |
Ⅴ | ON | ON | - | 30min |
Ⅵ | - | ON | - | 1H |
VII | - | - | - | +∞ |
Daylight Sensor
1 | 2 | 3 | 4 | ||
Ⅰ | - | - | ON | ON | 2 |
Ⅱ | - | - | - | ON | 5 |
Ⅲ | - | ON | ON | - | 10 |
Ⅳ | - | - | ON | - | 25 |
Ⅴ | - | ON | - | - | 50 |
Ⅵ | ON | - | - | - | 100 |
VII | - | - | - | - | Disable |
Stand-by DIM Level
5 | 6 | ||
Ⅰ | ON | ON | 50% |
Ⅱ | - | ON | 30% |
Ⅲ | ON | - | 20% |
Ⅳ | - | - | 10% |
Initialization
On/Off function /3-step dimming function: After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light. During the initialization, the sensor is not able to detect movement. 2/ 2-step dimming function: After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it dims the light to a low light level (set by stand-by dim level). During the initialization, the sensor is not able
Factory setting
Detection area: 100%, Hold time: 5s, Stand-by Period: 5s, Stand-by dim level: 10%, Daylight Sensor: Disable
Application notice
1. The sensor should be installed by a qualified electrician. And ensure that the electricity supply is switched off before installing or servicing the product.
2. Installation inside a glass or plastic housing will result in a reduction of detection sensitivity. Expect a reduction of approximately 20% for every 3mm of thickness.
3. Detection area will be affected by speed of motion, height of installation and volume of moving object.
4. Daylight sensor was tested on sunny environment with no lampshad
5. Sensors settings may need to be adjusted to match installation site, please follow below instructions or contact manufacturer.
6. The sensor is designed for indoor use only. Outdoor use for a long time may reduce the waterproof effects. The raining or wind blowing may trigger the microwave sensor even if without human motion when outdoor use.
7. The distance between any two sensors should be at least 3m to avoid interference with each other.
8. When the microwave sensor is installed in a metal lighting fixture or space with large reflector, for example a warehouse with metal roof, the microwave will be reflected and cause the lights permanently illuminated even if without motion signal. Please reduce the detection area (sensitivity) to solve the problems, or contact the microwave sensor manufacturer to provide technical support.
9. Make sure the sensor not close to or be blocked by high density material, such as metal, glass, concrete walls etc. The materials will reduce or block microwave and cause false trigger.
10. Make sure there are no fans or other vibrating objects in installation area. The movements will trigger sensor as well.
11. You are advised to test 5 samples before mass application of sensor in a new lighting project.