Description
The most advanced, innovative and user friendly digital aerosol
photometer available today, it is portable, yet rugged, and the
ideal instrument for in-situ filtration system integrity testing.
Utilizing the iProbe provides full functionality away from the base
unit, minimizing downtime and maximizing efforts in the field.
The photometer is also available with a sealed sample train for use
in nuclear and other hazardous environments.
Innovative User Interface
The base instrument’s 4.3” Liquid Crystal Display gives life to the
easy to use, menu driven interface. Aerosol measurements and pump
sampling rates are prominently displayed for easy viewing.
System parameters and selections such as alarm types, alarm set
points and aerosol reagent are shown on the lower menu bar, while
icons at the top of the screen give the status of connected
peripherals, reporting functions, and aerosol noise suppression
selections.
iProbe
The iProbe acts as an extension of the base instrument through a
nearly identical user interface. All status and selection icons
from the base unit are represented on the iProbe. With the press of
a button, the sampling location can be remotely selected and
switched by way of an electronically controlled valving system.
Data Reporting
Three unique report functions are now available with it through the
USB or optional thermal printer interface.
Continuous mode offers the same output as photometers to ensure backward
compatibility.
Monitoring mode provides the ability to collect data at user defined intervals for
long term sampling.
Summary mode, which gives discrete reporting capability for individual filter
locations, can output to the thermal printer to meet customer
documentation requirements.
Performance Guaranteed
To ensure consistent results in all applications and altitudes, the
sampling flow rate is constantly monitored and controlled via a
pulse width modulated pump.
The photometer has been independently tested and qualified to
ensure compliance with all applicable electrical and safety
requirements.
Hazardous Environments
Designed for the rigors of nuclear and other hazardous
applications, the 2i can be equipped with a unique, sealed sample
train. The unit is engineered to allow safe removal and replacement
of contaminated sampling components.
Simple maintenance
Annual NIST traceable calibration service is provided by
calibration facility. Calibration includes setting the aerosol
reagent references, sample flow reference points, operating
voltages, and servicing the light scattering chamber assembly.
Routine preventative maintenance entails cleaning and inspection of
internal sample tubing and connections, the internal reference
filter, and iProbe.
Enhanced Features
Upstream aerosol mass concentrations are displayed in actual mass
concentration values of micrograms per liter (μg/l).
User settable Aerosol Noise Suppression
(ANS) allows for more stable aerosol measurements when poor mixing
is present.
Portable Photometer Specifications
SIZE: 10.1” W × 13.0” D × 6.0” H (25.7 cm × 33.0 cm × 15.2 cm)
WEIGHT: Base unit – 19.0lbs (8.6Kg), Ensemble - 48lbs (21.8Kg)
POWER: Voltage: 100 to 250 Volts AC, 50/60Hz automatic adjustment, Consumption:
0.5 amps @ 120V, 0.25 amps @ 240V
AUTO ZERO: Automatically establishes zero reading at startup
ALARM: User selectable audible, visual, and vibratory alarms notify the
user when the user defined set point is exceeded.
FLOW CONTROL:
Pulse Width Modulation (PWM) control ensures sampling rate of 1cfm
(28.3lpm) +/- 10% in all applications.
REAGENT SETTINGS:
PAO-4, DOP, Ondina, PEG, Krydol, Corn Oil, Mineral Oil, Paraffin
DYNAMIC RANGE:
Up to 600 micrograms per liter
SENSITIVITY:
1% of readings for readings between 0.01% to100%
REPEATABILITY:
0.5% of readings for readings between 0.01% to 100%
LIGHT SOURCE:
Solid State, rated for life of instrument
DATA OUTPUT:
USB Connection
REPORTING:
Continuous, Summary, and Monitoring modes
PRINTER ACCESSORY:
Thermal Printer for hard copy of Summary Report, dedicated port
Email:sales2@norda-china.com sales2@norda-china.com
Skype:lingx360 Skype:lingx360 Skype:lingx360
www.nordachina.com www.nordachina.com www.nordachina.com
www.nordachina.net www.nordachina.net www.nordachina.net
www.norda-cleanroom.com www.norda-cleanroom.com www.norda-cleanroom.com
|   | 
 VD100 Aerosol Diluter  testing HEPA Leak Detection KM (Germany)
                                                                                    
                        
                        
                        
                                                            VD100 Aerosol Diluter  testing HEPA Leak Detection KM (Germany)
                                                    
                        
                     Aerosol photometer for HEPA filter detection in FFU  HVAC DP-30
                                                                                    
                        
                        
                        
                                                            Aerosol photometer for HEPA filter detection in FFU  HVAC DP-30
                                                    
                        
                     Aerosol Photometer  DP-30 ,Spectrometer
                                                                                    
                        
                        
                        
                                                            Aerosol Photometer  DP-30 ,Spectrometer
                                                    
                        
                     Digital Aerosol Photometer Model DP30 by PAO/DOP for Leak Detection
                                                                                    
                        
                        
                        
                                                            Digital Aerosol Photometer Model DP30 by PAO/DOP for Leak Detection
                                                    
                        
                     Aerosol photometer DP-30 HEPA leak detection  By PAO or DOP for pharmacutical
                                                                                    
                        
                        
                        
                                                            Aerosol photometer DP-30 HEPA leak detection  By PAO or DOP for pharmacutical
                                                    
                        
                     HEPA  filter integrality detection model DP-30  testing HEPA filters by PAO/DOP
                                                                                    
                        
                        
                        
                                                            HEPA  filter integrality detection model DP-30  testing HEPA filters by PAO/DOP
                                                    
                        
                     Aerosol Generator  testing HEPA Leak Detection and HEPA Filters with DOP/PAO in Cleanroom TDA 5C,TDA 4B,TDA-5D
                                                                                    
                        
                        
                        
                                                            Aerosol Generator  testing HEPA Leak Detection and HEPA Filters with DOP/PAO in Cleanroom TDA 5C,TDA 4B,TDA-5D
                                                    
                        
                     DOP SP200 method of filter integrality detection  for dop HEPA integrality test  and HEPA Leak Detection
                                                                                    
                        
                        
                        
                                                            DOP SP200 method of filter integrality detection  for dop HEPA integrality test  and HEPA Leak Detection
                                                    
                        
                     aerosol photometer ATI 2i
                                                                                    
                        
                        
                        
                                                            aerosol photometer ATI 2i