| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Deep Cycle Lithium Battery |
|---|---|
| Brand Name: | Topband |
| Model Number: | TB4820F-T110A |
| Certification: | ISO9001, ISO14001, MSDS |
| Place of Origin: | China |
| MOQ: | 10pcs |
| Price: | Negotiable |
| Payment Terms: | L/C, T/T |
| Supply Ability: | 450Mwh/year |
| Delivery Time: | 2~4weeks for samples; 4~6weeks for mass production |
| Packaging Details: | standard export carton |
| Material: | LiFePO4 |
| Norminal voltage: | 48V |
| Norminal capacity: | 20Ah |
| Cycle life: | ≥2000 (100% DOD) |
| Dimension: | 485* 88.5* 256mm |
| Weight: | 12kg |
| Internal Impedance: | ≤60mΩ |
| Warranty: | 2 years |
| NO. | Items | Characteristics | Testing Methods | |
| 1 | Nominal Voltage | 48V | Follow | |
| 2 | Nominal Capacity | 20Ah | Follow | |
| 3 | Minimum Capacity | 19Ah | Follow | |
| 4 | Battery internal Impedance | Internal Impedance≤60mΩ, | Internal Impedance Testing Machine( HIOKI 3555,1kHz ) | |
| 5 | Shipment Voltage | 51V~56V | Multi-meter | |
| 6 | Dimension | L ngth | 485* 88.5* 256mm | Vernier caliper |
| Width | ||||
| Height | ||||
| 7 | Working Temperature | Charge | 0~50℃,45~85%RH | Temperature & Humidity Instruments |
| Discharge | -20~60℃,45~85%RH | |||
| 8 | Storage empe ature & Humidity Range | Short: above one month | -20~+55℃,45~85%RH | Temperature & Humidity Instruments |
| Medium: above three months | 0~+45℃,45~85%RH | |||
| Long:above one year | +5~+30℃,45~85%RH | |||
| 9 | Allowed maximum continuous charge current | 30A | Multi-meter | |
| 10 | Allowed maximum continuous discharge current | 30A | Multi-meter | |
| 11 | Allowed maximum reverse charge voltage | NO Allowed | / | |
| 12 | Allowed maximum charge voltage | 58.4±0.2V | Multi-meter | |
| 13 | Discharge cut-off voltage | 40±1V | Multi-meter | |
| 14 | weight | About:12 KG | electronic scale | |
| 15 | Balanced function | / | / | |
| 16 | Display voltage | Yes (Precision 1%) | / | |
| Display current | Yes (Precision 2%) | / | ||
| 17 | Display capacity | Yes (Precision 10%) | / | |
| 18 | Communication | Master RS232 Communication /Slave RS485 | / | |
| No. | Items | Standards | Testing Methods |
| 1 | Short-Circuit | NONE | Prohibit output electrode short circuit |
| 2 | Over Discharge Protection Test | The battery should be no remarkable breakage, distortion. Appearance and charge are normal. | Discharge the battery at the rate of 0.2C with the load of 30Ω for 24h . Charging for 10sec with specified adapter , and check the voltage(≥37V) |
| 3 | Impact Test | The battery should be no explosion or catch fire | Place a full charged battery on a flat and put a stainless steel stick (Diamond 7.9mm) in the middle of the battery upright . Beat the steel stick with 9.1Kg |

|