| Sign In | Join Free | My benadorassociates.com | 
              
  | 
      
| Categories | Pneumatic Pulse Valve | 
|---|---|
| Brand Name: | NBSANMINSE | 
| Model Number: | SMDF - DNA - J | 
| Certification: | ISO9001 | 
| Place of Origin: | NINGBO | 
| MOQ: | 10PCS | 
| Price: | Negotiation | 
| Payment Terms: | L/C,T/T | 
| Supply Ability: | 10000PCS | 
| Delivery Time: | 5-30 days | 
| Packaging Details: | Box | 
| Nominal Pressure: | 1.0 ( MPa ) | 
| Type: | Inlet Valve | 
| Temperature: | ≤200℃ | 
| Max test press: | 1.5 ( MPa ) | 
| DN1XDN2: | 200X350 , 200X530 , 250X350 , 250X400 ,300X450 | 
| Valve body: | Cast iron | 
| Company Info. | 
| Ningbo Sanmin Import And Export Co.,Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
High Performance Double Disc Valve Temperature ≤ 200℃ SMDF-DNA-J
Production information
. Rotating disc valve employs ceramic or hard metal friction pair structure , which makes it more abrasive and better tightness . It just needs a small starting load because the unique structure . Besides , ashes hardly accumulate in the valve body due to the same reason . All these features make the rotating disc valve durable .
Operating Principle
Applications
. The rotating disc valve can be used in ash conveying system in thermal power plants. It also can be applied in mine , cement plant , lime work , metallurgic plant , chemical factory and other fields that need to convey caustic or abrasive ash .
Technical Parameters
. Maximum operating pressure: 1.0 MPA
. Maximum test pressure: 1.5 MPA
. Operating temperature: ≤ 200℃
. Leakage test pressure: 1.1 MPA
Installation
1. Prior to installation , please read this manual carefully , and check the pneumatic actuator’s condition .
2. Ensure the flange’s dimension , maximum operating pressure and inside nominal diameter meet the requirements .
3. Do not adjust the bolts and nuts . And make sure the center of two pipelines and valve center are coaxial . Flange surface should be smooth and keep horizontal without relatively large slope , for make sure the valve can fasten and work well . Besides , the bolts should be symmetrically fastened .
4. After installation , pump air into the two air intakes of the pneumatic actuator , and make sure the valve plate work properly .
5. If the control switch is installed , ensure its parameters can meet the external power source and it can work properly in fully open or fully close .
Troubleshooting Method
| Troubles | Cause | Troubleshooting Method | 
| Leakage | Foreign body | Remove foreign body | 
| Seal washer is invalid | Replace seal washer | |
| Valve core abrasion | Replace valve core | |
| Valve cannot open or close | Rotatable parts become flexible or invalid | Adjust or replace the relative parts | 
| Insufficient pressure or leakage | Check and repair supply air line | |
| Pneumatic components become ageing or invalid | Replace the relative pneumatic components | 
Installation dimension and outline
| DN | H | D | K | d | n-C | 
| 150*150 | 310 | 285 | 240 | 210 | 8-Φ22 | 
| 200*200 | 310 | 340 | 295 | 265 | 8-Φ22 | 
| 225*225 | 310 | 370 | 325 | 295 | 8-Φ22 | 
| 250*250 | 330 | 395 | 350 | 320 | 12-Φ22 | 
| 300*300 | 330 | 445 | 400 | 368 | 12-Φ22 | 
| 200*350 | 310 | 520 | 470 | 265 | 8-Φ22 | 
| NO. | Item | Material | NO. | Item | Material | 
| 1 | Upper valve body | Ductile cast iron | 5 | Under valve body | Ductile cast iron | 
| 2 | Seal ring | Ceramic or alloy | 6 | Rotating shaft | 45# Steel | 
| 3 | Valve plate | Ceramic or alloy | 7 | Rotary arm | Ductile cast iron | 
| 4 | Swing arm | Ductile cast iron | 8 | Pneumatic actuator | Aluminum | 

                                 
                             |