| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Flammability Test Chamber | 
|---|---|
| Brand Name: | HOOHA | 
| Model Number: | ZY6239 | 
| Certification: | GB/T12441-2005 (appendix A) | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Supply Ability: | 10 sets/month | 
| Delivery Time: | 30 work days | 
| Packaging Details: | wood package | 
| Price: | USD 3000-80000/SET | 
| Payment Terms: | L/C, T/T, Western Union | 
| color: | white | 
| adopt standard: | GB/T12441-2005 | 
| Power requirements: | AC220 (plus or minus 10%) V/50HZ | 
| Air source: | liquefied petroleum gas or natural gas | 
| delivery: | 30 working days | 
| payment: | T/T 100% | 
AC220V Flammability Testing Labs , Big Board Method Flame Test Chamber
Scope of application:
Under the conditions of the test, the test method for the resistance of the flameproof coating on the surface of the combustible substrate is tested, and it is also applicable to the determination of the flame resistance time of the flamefaced fire retardant coating
Meet the standard:
GB/T12441-2005 (appendix A)
Main parameters:
1. The structure of this instrument (fireproof paint burning testing machine) is composed of main control box, air blast device, burning bracket, and combustion burner. The control box is movable.
2. The frame is made of high quality 304 stainless steel square, and the control box is made of (t= 1.2mm). The surface is sprayed and sprayed to make it more clean and beautiful.
3. The sample size L900*W900 thickness is 5mm and the surface is smooth and smooth.
4. PLC control temperature, can record data at the same time and curve display.
5. The outer diameter of the thermocouple is not greater than 3mm; Wire diameter 0.5 mm, the accuracy is not lower than Ⅱ level, a range of 1300 ℃.
6, sample back fire five road surface thermocouple temperature measurement, automatic alarm when the temperature of 220 ℃.
7. Air source: liquefied petroleum gas or natural gas.
8. Blower wind speed through frequency converter, automatically adjust to meet the standard temperature.
9. Power requirements: AC220 (plus or minus 10%) V/50HZ
10. The control box adopts PLC+ touch screen. All electronic components are used in domestic leading brands, which can better guarantee the performance and accuracy of the machine.
11. The equipment has the following safety protection devices: power overload, short circuit protection and overload protection of control loop.
|   | 
 GB/t5464-2010 ZY6017D building material incombustibility testing machine
                                                                                    
                        
                        
                        
                                                            GB/t5464-2010 ZY6017D building material incombustibility testing machine
                                                    
                        
                     Gb4610-2008 ZY6069 sets the temperature meter
                                                                                    
                        
                        
                        
                                                            Gb4610-2008 ZY6069 sets the temperature meter
                                                    
                        
                     GB/t16172-2007 ZY6243 conical calorimeter
                                                                                    
                        
                        
                        
                                                            GB/t16172-2007 ZY6243 conical calorimeter
                                                    
                        
                     GB/T9978.1-2008 ZY6248A-SV fire exhaust fan high temperature testing furnace
                                                                                    
                        
                        
                        
                                                            GB/T9978.1-2008 ZY6248A-SV fire exhaust fan high temperature testing furnace
                                                    
                        
                     GB12955-2008 ZY6248D fire door opening and closing reliability testing device
                                                                                    
                        
                        
                        
                                                            GB12955-2008 ZY6248D fire door opening and closing reliability testing device
                                                    
                        
                     GB/T9978.1-2008 ZY6248/ZY6236A/ZY6236 member refractory vertical furnace
                                                                                    
                        
                        
                        
                                                            GB/T9978.1-2008 ZY6248/ZY6236A/ZY6236 member refractory vertical furnace
                                                    
                        
                     tunnel test ZY6254 wind tunnel tester (subway high-speed rail)
                                                                                    
                        
                        
                        
                                                            tunnel test ZY6254 wind tunnel tester (subway high-speed rail)
                                                    
                        
                     10MW heat release rate test device with Siemens spare parts
                                                                                    
                        
                        
                        
                                                            10MW heat release rate test device with Siemens spare parts
                                                    
                        
                     UL 790 ZY6271 roof/photovoltaic module combustion tester
                                                                                    
                        
                        
                        
                                                            UL 790 ZY6271 roof/photovoltaic module combustion tester
                                                    
                        
                     GB/T25352-2010 The ZY6288 insulation insulation material is resistant to burning and testing machine
                                                                                    
                        
                        
                        
                                                            GB/T25352-2010 The ZY6288 insulation insulation material is resistant to burning and testing machine