| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Generator Load Bank | 
|---|---|
| Brand Name: | KAIXIANG | 
| Model Number: | 5000 KW | 
| Certification: | ISO9001 | 
| Place of Origin: | HEBEI CHINA | 
| MOQ: | ONE SET | 
| Price: | negotiable | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 20 SETS ONE MONTH | 
| Delivery Time: | ONE MONTH AFTER GET DEPOSIT | 
| Packaging Details: | WOODEN CASE | 
| Resistive load: | 2500 KW | 
| PF: | -0.9-1 | 
| Load Tolerance: | ±3% | 
| Rating Voltage/Frequency: | 10500V/50Hz, 3 phase 3 wire | 
| Load Resolution: | Resistive:100.200.400.500.500.800kw Inductive:50.100.200.250.250.400kvar Capacitive:50.100.200.250.250.400kvar | 
| weight: | 23000 kg | 
Testing on Generator SetsFrequency 10kV 5000kVA Generator Load Bank
Product Description
1. Supply most robust, high-capacity designs
2. intelligent operator controls,safety indication layouts, adjustable load step resolution, and lightweight designs
3. solution for regularly scheduled maintenance testing and commissioning of mission-critical standby emergency power systems
Technical Parameter
| Rating Voltage/Frequency | 10500V/50Hz, 3 phase 3 wire | 
| Rated power | Resistive:2500kw Inductive:1250kvar Capacitive:1250kvar | 
| Load Resolution | Resistive:100.200.400.500.500.800kw Inductive:50.100.200.250.250.400kvar Capacitive:50.100.200.250.250.400kvar | 
| PF(Power Factor) | -0.9-1 | 
| Load Tolerance (each step) | ±5% | 
| Load Tolerance(overall) | ±3% | 
| Display Precision | 0.5 class | 
| Control Power | 220VAC/50Hz, | 
| Weight | About 23000kgs/set | 
| Size | 12192*2438*2591mm | 
Product Advantages
1. Multiple control mode: (1) manual panel control (2) remote control (3)software control
2. Multiple display function: voltage, current, frequency, power factor, active power, reactive power, apparent power etc.
3. Multiple protection function: overvoltage, overcurrent, overheat, over low blowing rate, blower overheat, blower phase sequence reverse protection, smoke alarm etc.
4. Forced air cooling: industrial heavy duty fan, horizon air intake, upwards outlet, low noise.
Application
1. Manufacturers of small gas engines also use load banks to test newly manufactured engines under various mechanical loads.
2. This is accomplished by connecting the engine to the load bank via a device called a dynamometer.
3. engine performance is monitored and, if necessary, adjustments are made to ensure the product performs within intended specifications.

|   | 
 Ocean Engineering Flexible Control Mode Generator Testing Load Bank 4000 KW Power 3 Phase
                                                                                    
                        
                        
                        
                                                            Ocean Engineering Flexible Control Mode Generator Testing Load Bank 4000 KW Power 3 Phase
                                                    
                        
                     10.5 KV Generator Load Bank Real Time Monitor For Sea Trial Test
                                                                                    
                        
                        
                        
                                                            10.5 KV Generator Load Bank Real Time Monitor For Sea Trial Test
                                                    
                        
                     2000 KW 3 Phase 3 Wire Generator Load Bank Durable With RS232 Interface
                                                                                    
                        
                        
                        
                                                            2000 KW 3 Phase 3 Wire Generator Load Bank Durable With RS232 Interface
                                                    
                        
                     11KV Resistive High Voltage Generator Load Bank 2000kW For Power Plant Testing
                                                                                    
                        
                        
                        
                                                            11KV Resistive High Voltage Generator Load Bank 2000kW For Power Plant Testing
                                                    
                        
                     10 KV 5000 KVA Dummy Load Bank Powder Coated For Testing Generator Sets
                                                                                    
                        
                        
                        
                                                            10 KV 5000 KVA Dummy Load Bank Powder Coated For Testing Generator Sets
                                                    
                        
                     Auto Full 6.6 KV 2000 KW Power Generator Load Bank For Communication
                                                                                    
                        
                        
                        
                                                            Auto Full 6.6 KV 2000 KW Power Generator Load Bank For Communication
                                                    
                        
                     High Efficiency 2000KW Generator Load Bank 10.5KV /5 0Hz Frequency
                                                                                    
                        
                        
                        
                                                            High Efficiency 2000KW Generator Load Bank 10.5KV /5 0Hz Frequency
                                                    
                        
                     For Generator RLC Load Bank With Intelligent  Control Vertical Outline Cooling
                                                                                    
                        
                        
                        
                                                            For Generator RLC Load Bank With Intelligent  Control Vertical Outline Cooling
                                                    
                        
                     Robust Resistive Load Bank ,High Capacity AC Load Bank For Generator Power
                                                                                    
                        
                        
                        
                                                            Robust Resistive Load Bank ,High Capacity AC Load Bank For Generator Power
                                                    
                        
                     Remote Control Dummy Load Bank Waterproof F Insulation Grey Case
                                                                                    
                        
                        
                        
                                                            Remote Control Dummy Load Bank Waterproof F Insulation Grey Case