| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Rubber Injection Moulding Machine |
|---|---|
| Brand Name: | TuoWei |
| Model Number: | TW-P2-200T |
| Place of Origin: | China |
| MOQ: | 1group |
| Price: | USD21739-23000/group |
| Payment Terms: | T/T |
| Supply Ability: | 30work days |
| Delivery Time: | 30work days |
| Packaging Details: | simple packaging |
| Type: | TWP-200T |
| color: | blue |
| Clapping force(TON): | 200 |
| Stroke(MM): | 250 |
| Working Plate Size(MM): | 550*560 |
| Dimeter of cyhnder(MM): | 355 |
| Horse powet(HP): | 10*2 |
| Heater power(KW): | 25 |
| Total power(KW): | 42 |
| Gross weight(KG): | 7000 |
| Machine size(MM): | 2900*2200*2000 |
| Type | TWP-200T |
| color | blue |
| Clapping force(TON) | 200 |
| Stroke(MM) | 250 |
| Working Plate Size(MM) | 550*560 |
| Dimeter of cyhnder(MM) | 355 |
| Horse powet(HP) | 10*2 |
| Heater power(KW) | 25 |
| Total power(KW) | 42 |
| Gross weight(KG) | 7000 |
Vulcanizing machine daily inspection and maintenance
A. routine inspection and maintenance
1) check whether the photoelectric mold closing device is sensitive and reliable;
2) check the part of the electric heating board to see whether the fixing of the electric heating board is
firm and whether the wiring is short circuit;
3) check whether there is oil leakage in motor oil pump, piping and valve;
4) check the height of fuel tank level;
5) check the flow of cooling water;
6) check for abnormal sounds in motor oil pump, piping, valve,
etc.;
7) the machine up and running, hours after the oil temperature
should be generally within 35 ° C ~ 50 ° C;
8) check whether the system pressure is normal.
B. weekly inspection and maintenance
1) if the solenoid valve is heated, check its vibration and wiring;
2) whether the fastening screw of limit switch is loose;
3) whether the pipe joint is loose;
4) whether the filter is blocked.
C. Check and maintain monthly
1) check the oil pollution of the work;
2) cleaning inside and outside the machine;
3) check screw and barrel.
D. annual inspection and maintenance
1) whether the circuit wiring is loose;
2) setting state of limit switch;
3) check the wear condition of the mechanical part, whether the
fixed screw is loose, and tighten it.