| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Single Phase Energy Meter Test Bench | 
|---|---|
| Brand Name: | SHENGDI TECHNOLOGY | 
| Model Number: | HS6103F | 
| Certification: | GS,CNAS | 
| Place of Origin: | ZHEJIANG,CHINA | 
| MOQ: | 1 SET | 
| Price: | USD$1~100000/SET | 
| Payment Terms: | TT,LC | 
| Supply Ability: | 3000 sets/Years | 
| Delivery Time: | 35~45days | 
| Packaging Details: | WOODEN CASE | 
| Phase: | 1 phase | 
| Accuracy: | 0.05% CLASS | 
| Voltage: | Max.240V | 
| Current: | Max.120A | 
| Power supply: | 230 V + 10% -15%,50/60 Hz | 
| Company Info. | 
| Zhejiang Shengdi Technology Inc. | 
| View Contact Details | 
| Product List | 
HS-6103F SINGLE PHASE ENERGY METER TEST BENCH
with 40 positions for electronic kWh meter, fission type by two fixing racks, automatic change to calibrate/test line and neutral
This specification for single phase dual loop energy meter test bench.
Voltage Source:
1. Output Voltage Range: 0- 275/300V
2. Output Max Power: 800VA
3. Resolution: 0.01%
4. Stability: Better than 0.05% / 3 Min(Time base 5S)
5. Distortion factor: < 0.5% at linear load;
6. Frequency range: 45Hz~65Hz;
7. Power efficiency: more than 85%;
8. Ambient temperature:10℃~50℃
9. Electronic overload and short-circuit protection.
Current Source:
1. Output current: range: 1mA~100A+/-20%;
2. Output maximum power: 2000VA
3. Resolution: 0.01%;
4. Stability: better than 0.05%/3 min(time base 5S);
5. Distortion factor: < 0.5% at linear load;
6. Frequency range: 45Hz~65Hz;
7. Power efficiency: greater than 85%;
8. Ambient temperature:10℃~50℃
9. Electronic overload protection and security for open current circuit.
Reference Meter:
HS-5100 Single Phase Reference Meter Accuracy class: 0.05%
Accessories:
1. Phase Angle: 0°~360°, resolution of phase angle setting: 0.1°;
2. Output frequency range: 45Hz~65Hz; resolution: 0.01Hz
3. Output stability of power: <0.05% (180S)
4. Input power: 230~240V±10%, 50/60Hz;
5. RS232 connectors for each position to be connected to Serial Ports Server,(for meter calibration & programming)
6. Current Connection Type: LNNL (1-4, 3-2) (Dual Loop)
Main Information:
| No. of test Meters | Standard: 24 and 48 ,Also 3-60 Meters are available | 
| Accuracy Class | 0.05% or 0.1% | 
| Output Voltage | 220 or 240V,Range:0~125% | 
| Output Current | Standard: Max120A Custom: 200A | 
| Test Function | Accuracy testing, creep testing(no load testing), starting Up testing, harmonic testing, repeatability testing, influencing testing, dial testing etc. | 
| Communication Mode | 1.Bus | 
Dimensitions:
| integration | stations | Number of rack | dimension:L×W×H | fission | stations | Number of rack | dimension:L×W×H | 
| 6 | 1 | 1600×750×1600 | 12 | 1 | 1600×700×1920 | ||
| 1600X800X1100 | 24 | 1 | 2200×700×1920 | ||||
| 12 | 1 | 1600×750×1920 | 48 | 2 | 2200×700×1920 | ||
| 24 | 1 | 2200×750×1920 | 60 | 2 | 2000×700×1920 | ||
| 48 | 2 | 2200×750×1920 | cabinet | 600×800×1920 | |||

DELIVERY



|   | 
 Single Phase Meter Test Bench,48 calibrated energy meter, 0.001Amps~120Amps,30~300Volts
                                                                                    
                        
                        
                        
                                                            Single Phase Meter Test Bench,48 calibrated energy meter, 0.001Amps~120Amps,30~300Volts
                                                    
                        
                     12-16 Positions Single Phase Prepaid Digital KWH Meter Test Bench 1mA~120A Current,0.05% Accuracy Class
                                                                                    
                        
                        
                        
                                                            12-16 Positions Single Phase Prepaid Digital KWH Meter Test Bench 1mA~120A Current,0.05% Accuracy Class
                                                    
                        
                     12 Pcs Single Phase Prepaid Digital KWH Meter Test Bench 0.5mA~120A Current Range,0.05% Accuracy Class
                                                                                    
                        
                        
                        
                                                            12 Pcs Single Phase Prepaid Digital KWH Meter Test Bench 0.5mA~120A Current Range,0.05% Accuracy Class
                                                    
                        
                     12 position ANSI 4 IEC single phase test bench accuracy class 0.05% ANSI SOCKET Meter 0~100A current
                                                                                    
                        
                        
                        
                                                            12 position ANSI 4 IEC single phase test bench accuracy class 0.05% ANSI SOCKET Meter 0~100A current
                                                    
                        
                     48 position single phase energy meter test bench,0.1% Accuracy class.1-4,3-2 double CIRCUIT current meter for INDIA
                                                                                    
                        
                        
                        
                                                            48 position single phase energy meter test bench,0.1% Accuracy class.1-4,3-2 double CIRCUIT current meter for INDIA
                                                    
                        
                     Single phase energy meters test bench (10/20 meters at a time) 0.05%/0.1% Accuracy class Max.120A current
                                                                                    
                        
                        
                        
                                                            Single phase energy meters test bench (10/20 meters at a time) 0.05%/0.1% Accuracy class Max.120A current
                                                    
                        
                     Single phase test bench for digital energy meter 1~48 Positions,0.05% Accuracy class,0~100A current range
                                                                                    
                        
                        
                        
                                                            Single phase test bench for digital energy meter 1~48 Positions,0.05% Accuracy class,0~100A current range
                                                    
                        
                     HS-6103F Single-phase Digital kWh Energy Meter Test Bench 2 circuit current test 48 positions
                                                                                    
                        
                        
                        
                                                            HS-6103F Single-phase Digital kWh Energy Meter Test Bench 2 circuit current test 48 positions
                                                    
                        
                     Single Phase Electronic DIN Rail Active Energy Test Bench 30 Positions 0.05% Accuracy Class 0~100A current range
                                                                                    
                        
                        
                        
                                                            Single Phase Electronic DIN Rail Active Energy Test Bench 30 Positions 0.05% Accuracy Class 0~100A current range
                                                    
                        
                     HS-6103 Single Phase DIN Rail Electricity Meter Test Bench 30 Positions 0.05% Accuracy Class 0~100A current range
                                                                                    
                        
                        
                        
                                                            HS-6103 Single Phase DIN Rail Electricity Meter Test Bench 30 Positions 0.05% Accuracy Class 0~100A current range