| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | UPS Uninterrupted Power Supply | 
|---|---|
| Brand Name: | CONSNANT | 
| Model Number: | CND310 | 
| Certification: | CE, ISO9001, ISO14001 | 
| Place of Origin: | Shenzhen, China | 
| MOQ: | 1 | 
| Price: | Negotianle | 
| Payment Terms: | T/T, L/C, Western Union | 
| Supply Ability: | 100 sets per month | 
| Packaging Details: | Export Standard Package | 
| Voltage Accuracy: | 220V±1%(steady load) 220V±3%( fluctuating load) | 
| Frequency range: | 50/60Hz±0.05Hz(powered by battery) | 
| Output Power Factor: | 0.8 | 
| THD: | Linear load<2%, non linear load<4% | 
| Dynamic transients: | <5% | 
| Display: | LCD | 
PDU Series Feeder Electricity UPS System Single / Three Phase
10 - 100KVA
Description:
CND310 system consists of electrical UPS, DBW bypass stablalized
cabinet, and feeder cabinet of PDU series. It possesses on-line
double conversion and zero switch function. It can be mainly
applied for power system telemechanics, PTU, power line
communication, power system monitoring and etc.. After being
isolated and filtered by regulator, Single-phase 220V or
three-phase 380V can provide stable power for load through inverter
when the AC is normal. If the failure of AC power grid supply or a
power cut occurs, direct current panel, the backup of power system,
can invert to supply electricity through non-return diode. If the
direct current panel is under voltage or cut off, static switch can
shift to bypass stabilized cabinet to supply electricity. When the
AC power becomes normal, the static switch automatically shift to
AC power grid to supply electricity reversely. If the inverter is
overloaded or the fault occurs to it, the static switch shift to
bypass stabilized cabinet to supply electricity and indicates a
warning signal at the same time.
Key Features:
Mainly Application:
Optional:
SNMP card,Dry contact card, Signal transmitter, Bypass isolation
and voltage regulation, Increase feeder circuit (standard for 8
loops), 12 pulse rectifier, the appearance of special
models(standard dimension:800×600×2260mm)
FAQ:
Q1: What's included in products?
A: It is included UPS unit, user manual, 2% spare parts for emergency, test
certificate(optional)
Q2. Your UPS meet CE requirements?
A:Our UPS is with the certificate of CE, ISO and Chinese TLC certificates.
Q3: Can we change the shape, size, color or printing based on the
original design?
A: Yes, and OEM, ODM accepted
Q4:. Can you design one specially?
A: Yes.
Specification:
| CND310 10KVA-100KVA | ||||||||||||||
| Model (KVA) | 10 | 15 | 20 | 30 | 40 | 50 | 60 | 80 | 100 | |||||
| Rating capacity(KW) | 8 | 12 | 16 | 24 | 32 | 40 | 48 | 64 | 80 | |||||
| Rating voltage | 220V(one-phase) /380V(three phase) | |||||||||||||
| AC input | ||||||||||||||
| Voltage range | ±25% | |||||||||||||
| Frequency range | 50,60Hz±10% | |||||||||||||
| Soft start | 0-100% in 5” | |||||||||||||
| Power factor | 0.95(with input filter) | |||||||||||||
| Bypass input | ||||||||||||||
| Permitted voltage range | ±15% | |||||||||||||
| Frequency range | 50/60Hz±5% | |||||||||||||
| Output | ||||||||||||||
| Voltage accuracy | 220V±1%(steady load) 220V±3%( fluctuating load) | |||||||||||||
| Permitted Frequency range | 50/60Hz±0.05Hz(powered by battery) | |||||||||||||
| Power factor | 0.8 | |||||||||||||
| THD | Linearload<2%, non linear load<4% | |||||||||||||
| Dynamic transients | <5% | |||||||||||||
| Current crest ratio | 3:1 | |||||||||||||
| Overload capacity | Normal in 110% load, 125% for 10min | |||||||||||||
| Efficiency | Double switch:94%, ECO:98% | |||||||||||||
| DC | ||||||||||||||
| Battery voltage | 220V | |||||||||||||
| Cutoff voltage | 185V | |||||||||||||
| Maximum discharge current | 36A | 55A | 73A | 109A | 145A | 181A | 218A | 291A | 364A | |||||
| Penal display | ||||||||||||||
| LCD | Chinese/English UPS status, operation instruction input voltage, output voltage, current, frequency, battery voltage, value of charge and discharge current, accident display, warning | |||||||||||||
| Environment | ||||||||||||||
| Temperature | 0ºC-40 ºC | |||||||||||||
| Humidity | 0-95%(no condensing) | |||||||||||||
| Storage temperature | -25 ºC—55 ºC | |||||||||||||
| Altitude | <1500m | |||||||||||||

|   | 
 Electricity UPS Uninterrupted Power Supply Intelligent Detection 10 - 100KVA
                                                                                    
                        
                        
                        
                                                            Electricity UPS Uninterrupted Power Supply Intelligent Detection 10 - 100KVA
                                                    
                        
                     Customized Electricity High Power UPS , Uninterruptible Power System 220V / 384V 10 - 100KVA
                                                                                    
                        
                        
                        
                                                            Customized Electricity High Power UPS , Uninterruptible Power System 220V / 384V 10 - 100KVA
                                                    
                        
                     Industrial Uninterruptible Power Supply DC = 384V / 480V , Large Capacity Industrial Ups Battery Backup
                                                                                    
                        
                        
                        
                                                            Industrial Uninterruptible Power Supply DC = 384V / 480V , Large Capacity Industrial Ups Battery Backup
                                                    
                        
                     30kVA - 1200kVA UPS Uninterrupted Power Supply , High Availability UPS Backup Power Supply
                                                                                    
                        
                        
                        
                                                            30kVA - 1200kVA UPS Uninterrupted Power Supply , High Availability UPS Backup Power Supply
                                                    
                        
                     IDC /  ISP ± 240VDC UPS Uninterrupted Power Supply 20 - 300KVA THDi < 3% Superior Energy Saving
                                                                                    
                        
                        
                        
                                                            IDC /  ISP ± 240VDC UPS Uninterrupted Power Supply 20 - 300KVA THDi < 3% Superior Energy Saving
                                                    
                        
                     Low Frequency UPS Uninterrupted Power Supply Three Phase 45 - 65Hz For Data Centers
                                                                                    
                        
                        
                        
                                                            Low Frequency UPS Uninterrupted Power Supply Three Phase 45 - 65Hz For Data Centers
                                                    
                        
                     Energy Saving UPS Uninterrupted Power Supply
                                                                                    
                        
                        
                        
                                                            Energy Saving UPS Uninterrupted Power Supply
                                                    
                        
                     Three Phase UPS Uninterruptible Power Supply , Computer Ups Battery Short Circuit Protection
                                                                                    
                        
                        
                        
                                                            Three Phase UPS Uninterruptible Power Supply , Computer Ups Battery Short Circuit Protection
                                                    
                        
                     Intelligent Single Phase UPS Uninterrupted Power Supply High Frequency For TCP / IP Network
                                                                                    
                        
                        
                        
                                                            Intelligent Single Phase UPS Uninterrupted Power Supply High Frequency For TCP / IP Network
                                                    
                        
                     220VAC 3KVA / 6KVA / 10KVA Distributed Power System Muninterruptible Power Supply Battery
                                                                                    
                        
                        
                        
                                                            220VAC 3KVA / 6KVA / 10KVA Distributed Power System Muninterruptible Power Supply Battery