| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Industrial Servo Motor |
|---|---|
| Brand Name: | Yaskawa |
| Model Number: | SGMPH-01AAA41 |
| Place of Origin: | Japan |
| MOQ: | 1 |
| Price: | negotiable |
| Payment Terms: | TT West Union |
| Supply Ability: | 100 |
| Delivery Time: | 2-3 work days |
| Packaging Details: | New in original box |
| Brand: | Yaskawa |
| Model: | SGMPH-01AAA41 |
| Output: | 0.1 KW |
| Maximum Torque: | 0.955 Nm |
| Rated Current: | 0.91A |
| Rated Torque: | 0.318 Nm |
| Max Speed: | 5000 1/min |
| Company Info. |
| Shenzhen Wisdomlong Technology CO.,LTD |
| Verified Supplier |
| View Contact Details |
| Product List |
Industrial Servo Motor SGMPH-01AAA41 Yaskawa 0.00000364 kg.m² 3000
1/min 0.91 A
QUICK DETAILS
DESCRIPTION
SEPCIFICATIONS
| Brand | Yaskawa |
| Model | SGMPH-01AAA41 |
| Place of Origin | Japan |
| Output | 0.1KW |
| Max Torque | 0.955Nm |
| Speed | 5000 1/min |
| Current | 0.91A |
| Torque | 0.318Nm |
| Max Current | 2.8A |
| Rotor Interia | 0.00000364 kg.m2 |
Be sure to set this parameter when installing an external
regenerative resistor. When set to the factory setting of “0,” the
SERVOPACK’s built-in resistor has been used. Set the regenerative
resistor capacity tolerance value.
When the set value is improper, alarm A.320 is not detected
normally. Also, do not set other than 0 without connecting the
regenerative resistor because alarm A.300 or A.330 may be detected.
The set value differs depending on the cooling method of external
regenerative resistor:
• For natural air cooling method: Set the value maximum 20% of the
actually installed regenerative resistor capacity (W).
• For forced air cooling method: Set the value maximum 50 % of the
actually installed regenerative resistor capacity (W). Example: Set
20 W (100 W)
IMPORTANT
1. When resistors for power are used at the rated load ratio, the
resistor temperature increases to between 200 °C and 300 °C (392 °F
and 572 °F). The resistors must be used at or below the rated
values. Check with the manufacturer for the resistor’s load
characteristics. Use resistors at no more than 20% of the rated
load ratio with natural convection cooling, and no more than 50% of
the rated load ratio with forced air cooling.
2. For safety’s sake, use the resistors with thermoswitches.
DIMENSIONS



TORQUE CURVE


SIMILAR PRODUCTS
| SGMPH-04ABA-SW11 | SGMPH-04ACA-SW11 |
| SGMPH-08A1A61 | SGMPH-08A1A61D-OY |
| SGMPH-08A1A-YR11 | SGMPH-08A1A-YR13 |
| SGMPH-08A2A-YR1 | SGMPH-08A2A-YR12 |
| SGMPH-08AAA21 | SGMPH-08AAA21/2C |
| SGMPH-08AAA2B | SGMPH-08AAA4B |
| SGMPH-08AAA6CD-OY | SGMPH-08AAAHB61 |
| SGMPH-15A1A21 | SGMPH-15A1A2B |
| SGMPH-15A1A2C | SGMPH-15A1A41 |
| SGMPH-15A1A4B | SGMPH-15A1A4C |
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG-

|