| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Secondary Current Injection Test |
|---|---|
| Brand Name: | GFUVE |
| Model Number: | GF101 |
| Certification: | ISO |
| Place of Origin: | China |
| MOQ: | 1 Set |
| Price: | Negotiable |
| Payment Terms: | T/T,, Western Union,Paypal |
| Supply Ability: | 200 Pieces Per Month |
| Delivery Time: | 3 - 7 Days |
| Packaging Details: | Standard Export Wooden Box |
| Accuracy class: | 0.05%, 0.1% |
| AC Current output Range: | 0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, Switch automatically |
| Harmonic Harmonic times: | 2nd-63th |
| Load capacity: | 40VA |
| Temperature drift: | 8 PPM/°C |
| Weight (kg): | 12 |
Program-controlled Single Phase Phantom Load Power Source
1 . Setting up and taking the load regulation of voltage, current,
phase and frequency of the power factor
2 . Amplitude 2nd-128th phase harmonics, and it can be added to the
fundamental wave in every harmonic output
3 . A wide range output of voltage and current, big power, high
stability, small waveform distortion degree
4 . Strong load ability, taking capacitive load, sensibility load,
resistive load or composite load, load regulation is higher than
0.01%
5 . Applying the 32-bit MPU + DSP + FPGA, powerful flexible;
6 . Using hardware PID, fast response, the change of load will not
cause volatility output.
7 . Power frequency waves reach up to 50000 points a week of the wave kneading, signal output without filter, precise waveform output, precise harmonic output, small harmonic distortion degree
Parameters
| Electrical parameters | |
| Accuracy class | 0.05%, 0.1% |
| Power supply | Single phase AC 85-265V, 50/60 Hz |
| AC Voltage output | |
| Range | 57.7V / 100 V / 220V / 380V, Switch automatically (max 500V) |
| Adjustment resolution | 0.01%, 0.1%, 1%, 10%, |
| Accuracy | 0.05% RG |
| Stability | Better than 0.01% RG / 1 min |
| Distortion degree | Better than 0.1% (not capacitive load) |
| Load capacity | 40VA |
| Full load regulation rate | Less than 0.01% RG |
| Full load regulation time | Less than 1ms |
| Temperature drift | 8 PPM / °C |
| Long-term stability | 60 PPM/year |
| AC Current output | |
| Range | 0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, Switch automatically |
| Adjustment resolution | 0.01%, 0.1%, 1%, 10%, |
| Accuracy | 0.05% RG |
| Stability | Better than 0.01% RG/1 min |
| Distortion degree | Better than 0.1% (not capacitive load) |
| Load capacity | 40VA |
| Full load regulation rate | Less than 0.01% RG |
| Full load regulation time | Less than 1mS |
| Temperature drift | 8 PPM / °C |
| Long-term stability | 60 PPM/year |
| Power output | |
| Active power accuracy | 0.05% or 0.1% |
| Reactive power accuracy | 0.1% or 0.2% |
| Stability | Better than 0.01% RG / 1 min |
| Phase | |
| Range | 0°-359.99° |
| Adjustment resolution | 0.01°, 0.1°, 1°, 10° |
| Accuracy | 0.03° |
| Frequency | |
| Range | 40-65 Hz |
| Adjustment resolution | 0.001 Hz, 0.01 Hz, 0.1 Hz, 1Hz |
| Accuracy | 0.002 Hz |
| Temperature drift | 0.5 PPM / °C |
| Long-term stability | 4 PPM/year |
| Harmonic | |
| Harmonic times | 2nd-63th |
| Adjustment resolution | 0.1% (Compared with fundamental wave) |
| Harmonic content (Compared with fundamental wave) | |
| Voltage | ≤ 40% |
| Current | ≤ 40% |
| Phase | 0°-360° |
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | 420x320x155 |
| Weight (kg) | 12 |
| Environmental conditions | |
| Operating temperature | 0°C to 40°C |
| Storage conditions | -30°C to 60°C |