| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | AC Resistive Load Bank | 
|---|---|
| Brand Name: | J-ENERGIZE | 
| Model Number: | JET-ACO 380/02 | 
| Place of Origin: | XIAN, CHINA | 
| MOQ: | 1 Unit | 
| Payment Terms: | L/C, T/T, Negotiable | 
| Delivery Time: | Negotiable | 
| Packaging Details: | Wooden Case | 
| Voltage measurement range: | AC 0~450V, Display Resolution: 0.1V, Precision: ±0.5% | 
| Current measurement range: | AC 0~100A, Display Resolution: 0.1A, Precision: ±0.5% | 
| Power measurement range: | 0~20 KVA, Display Resolution: 0.1KVA, Precision: ±1% | 
| Power factor measurement range: | 0.001~1.000, Display Resolution: 0.001, Precision: ±0.5% | 
| Type: | Resistive load bank | 
| Application: | Generator,UPS,Battery,Power Plant,Generator Load Test | 
| Product name: | 10KW Load Bank,AC variable resistive load bank for sale,battery test load bank | 
20KW Portable Load Bank For Generator Load Testing 3 Phase Load Bank
JET-ACO Series AC Resistive Load Bank
A load testing is part of the maintenance for a generator.
There are multiple reasons generator should undergo a load bank test on an annual basis, including but not limited to the following:
Test:
Functions & Features
◆ Test three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, running time, energies of generators and UPS.
◆ It has harmonic analysis of 2-50 orders of harmonic content and the total harmonic content for voltage or current.
◆ Set/adjust discharging power according to performance parameters and detection requirements
◆ Set discharging time, timing to automatic shut-off load, discharge off and alarm operator
◆ Set over/under voltage protection threshold value, it can shut off load, terminate discharging and alarm user automatically.
◆ Large LCD screen, friendly interface. English menu and easy operation.
◆ Parallel operation function to carry out multi sets load operation by RS 485 communication
◆ Built-in storage save 30 groups of test data, which can be viewed, deleted and export into SD card.
◆ Start/stop discharging control by Serial port, and detect data real time operation etc.; The storage data can be uploaded to PC by serial port or SD card, and the upper computer’s software can analyze data and pattern and print report etc.
◆ Overheating and over current protection function, it can turn off load, terminate discharging and alarm automatically when over temperature and over current.
◆ Set at most 5 groups power, load process automatically according to the setting power and operation time after being turned on.
Specifications
| Mode | JET-ACO 380/02 | JET-ACO 380/04 | JET-ACO 380/10 | ||||
| Load voltage | Three-phase AC380V, Single-phase AC220V | ||||||
| Operating power | Stand-alone: Max 20KW (Three-phase 380V) Max 6KW (Singly-phase 220V) | Stand-alone: Max 40KW (Three-phase 380V) Max 13KW (Singly-phase 220V) | Stand-alone: Max 100KW (Three-phase 380V) Max 30KW (Singly-phase 220V) | ||||
| Cooling mode | FCT (Fan control Temperature) | ||||||
| Communication Mode | RS232, RS485 and SD card | ||||||
| Display mode | 8-inch TFT | ||||||
| Voltage measurement range | AC 0~450V, Display Resolution: 0.1V, Precision: ±0.5% | ||||||
| Current measurement range | AC 0~100A, Display Resolution: 0.1A, Precision: ±0.5% | AC 0~150A, Display Resolution: 0.1A, Precision: ±0.5% | AC 0~300A, Display Resolution: 0.1A, Precision: ±0.5% | ||||
| Frequency measurement range | 40~60 Hz, Display Resolution: 0.01Hz, Precision: ±0.2% | ||||||
| Power measurement range | 0~20 KVA, Display Resolution: 0.1KVA, Precision: ±1% | 0~40 KVA, Display Resolution: 0.1KVA, Precision: ±1% | 0~100 KVA, Display Resolution: 0.1KVA, Precision: ±1% | ||||
| Power factor measurement range | 0.001~1.000, Display Resolution: 0.001, Precision: ±0.5% | ||||||
| Discharging Time | (0~19 hours and 59 minutes) adjustable continuously | ||||||
| Quantity of Parallel operation | 1~99 sets | ||||||
| Recording Period | 6~999 Seconds | ||||||
| Temperature measurement range | -20~100℃,Display resolution: 1℃, precision:±1℃ | ||||||
| Insulating strength | Input≥AC1500V, Output≥AC500V | ||||||
| Working environment | Working Temperature: (-20~55)℃, Storage Temperature: (-45~75)℃ Relative humidity: 90%(40±2℃) Atmospheric pressure: (70~106) KPa | ||||||
| Working power supply | Single-phase AC220V±10, 50Hz | ||||||
| MTTF | ≥50000h | ||||||
| Dimensions(mm) | 420×500×750mm | 680×600×900mm | 680×600×900mm | ||||
| Weight | 30kg | 50kg | 70kg | ||||
Service
1. Pre-service
-- 7/24 online service for your consult.
-- Help choose right model, and a series of service, person, advise.
2. Middle service
-- Give you best offer.
-- Provide discount for qty order.
-- Do customer's request.
-- Choose payment term as you convenient.
-- Delivery promptly, and inform you in time.
-- Provide invoice value as you like to decrease your tax.
3. After sale service
-- 1-year warranty service and all life maintenance.
-- Technical engineer are available for oversea training.
-- Free change for some parts.
-- Remote control technical service.
-- Free installation DVD
-- Maintenance plan.
|   | 
 20-50KW Portable AC Resistive Load Bank Single Phase For UPS Battery
                                                                                    
                        
                        
                        
                                                            20-50KW Portable AC Resistive Load Bank Single Phase For UPS Battery
                                                    
                        
                     3 Phase Variable AC Resistive Load Bank 200KW For Generator 8 Inch TFT Display
                                                                                    
                        
                        
                        
                                                            3 Phase Variable AC Resistive Load Bank 200KW For Generator 8 Inch TFT Display
                                                    
                        
                     100KW AC Resistive Load Bank , Generator Portable Resistive Load Bank
                                                                                    
                        
                        
                        
                                                            100KW AC Resistive Load Bank , Generator Portable Resistive Load Bank
                                                    
                        
                     200KW AC Resistive Load Bank 3 Phase Ac Load Bank Keyboard Operation Design
                                                                                    
                        
                        
                        
                                                            200KW AC Resistive Load Bank 3 Phase Ac Load Bank Keyboard Operation Design
                                                    
                        
                     Large LCD Screen AC Resistive Load Bank Diesel Generators Loading Capacity 40KW
                                                                                    
                        
                        
                        
                                                            Large LCD Screen AC Resistive Load Bank Diesel Generators Loading Capacity 40KW