| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Petroleum Testing Equipment | 
|---|---|
| Brand Name: | AI | 
| Model Number: | OST-525 | 
| Certification: | ISO | 
| Place of Origin: | China | 
| MOQ: | 1 set ASTM D525 Oxidation Stability Testing Equipment | 
| Price: | Negotiable | 
| Payment Terms: | L/C, T/T, Western Union | 
| Supply Ability: | 200 sets per month | 
| Delivery Time: | 30 days | 
| Packaging Details: | ASTM D525 Oxidation Stability Testing Equipment packed in Hardboard | 
| Test method: | Induction Period Method | 
| Power Supply: | AC220V /50HZ | 
| Temperature controlling range: | 100±0.1℃ | 
| Working units: | two bombs | 
| Total power: | 1.5KW | 
| Test standard: | ASTM D525 | 
| Test sample: | gasoline | 
| Warranty: | 1 Year | 
| Company Info. | 
| Advanced Instruments Co.,Limited | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Introduction
This oxidation stability testing equipment is used to determine the stability of gasoline in finished form only, under accelerated oxidation conditions.The induction period may be used as an indication of the tendency of motor gasoline to form gum in storage.
Characteristic
1. This oxidation stability testing equipment can automatically fill and discharge oxygen,automatic detect leakage.
2. The equipment can make Pressure-Time curve in real time,automatic judge turning point.
3. Dual independent oxygen bombs,won’t influence each other during test.
4. The oxidation stability testing equipment adopts big colorful touch screen is convenient to operate.
5. Over-temperature protection device has power off protection when temperature is higher than set temperature.
6. Bomb auxiliary heating device makes uniform temperature field.
Technical specifications
| 1 | Applicable standard | GB/T8018, ASTM D525, ISO7536, DIN51780, IP40 | 
| 2 | Temperature controlling method | Automatic controlled by PID | 
| 3 | Temperature controlling accuracy | 100±0.1℃ | 
| 4 | Display content | Windows interface ① Control temperature and set temperature; | 
| 5 | Working units | Two bombs | 
| 6 | Pressure correction | Connect precise pressure calibration instrument externally ,computer program can correct pressure deviation. | 
| 7 | Connect method | Imported stainless stell quick connector,no leakage | 
| 8 | Power consumption | 1.5KW | 
| 9 | Result print | It has inbuilt micro-printer,and can also connect printer with PC. | 
Photos of factory




|   | 
 ASTM D1881 Engine Coolants Foaming Tendencies Tester with Two Holes at  88℃
                                                                                    
                        
                        
                        
                                                            ASTM D1881 Engine Coolants Foaming Tendencies Tester with Two Holes at  88℃
                                                    
                        
                     Semi-automatic Rancimat Method Biodiesel Oxidation Stability Test Machine EN14112
                                                                                    
                        
                        
                        
                                                            Semi-automatic Rancimat Method Biodiesel Oxidation Stability Test Machine EN14112
                                                    
                        
                     ASTM D3945 Shear Stability of Polymer-Containing Fluids Tester
                                                                                    
                        
                        
                        
                                                            ASTM D3945 Shear Stability of Polymer-Containing Fluids Tester
                                                    
                        
                     Ferrous Wear Concentration versus PQ Index Wear Debris Test Instrument
                                                                                    
                        
                        
                        
                                                            Ferrous Wear Concentration versus PQ Index Wear Debris Test Instrument
                                                    
                        
                     ASTM D4294 Sulfur In Oil Testing Equipment by X-Ray Fluorescence Method
                                                                                    
                        
                        
                        
                                                            ASTM D4294 Sulfur In Oil Testing Equipment by X-Ray Fluorescence Method
                                                    
                        
                     Thermo-Oxidation Engine Oil Simulation Testing Equipment TEOST MHT ASTM D7097
                                                                                    
                        
                        
                        
                                                            Thermo-Oxidation Engine Oil Simulation Testing Equipment TEOST MHT ASTM D7097
                                                    
                        
                     Low Temperature Lubricating Oil Testing Equipment Brookfield Viscosity Tester
                                                                                    
                        
                        
                        
                                                            Low Temperature Lubricating Oil Testing Equipment Brookfield Viscosity Tester
                                                    
                        
                     EN 15751 Oxidation Stability Test Apparatus by Accelerated Oxidation Method
                                                                                    
                        
                        
                        
                                                            EN 15751 Oxidation Stability Test Apparatus by Accelerated Oxidation Method
                                                    
                        
                     ASTM D189 Conradson Carbon Residue Apparatus For Laboratory Oil Analysis
                                                                                    
                        
                        
                        
                                                            ASTM D189 Conradson Carbon Residue Apparatus For Laboratory Oil Analysis
                                                    
                        
                     ASTM D6304 Coulometric Karl Fischer Titration Equipment for Trace Moisture Test
                                                                                    
                        
                        
                        
                                                            ASTM D6304 Coulometric Karl Fischer Titration Equipment for Trace Moisture Test