Sign In | Join Free | My benadorassociates.com |
|
Categories | Appliance Performance Test Lab |
---|---|
Brand Name: | HongCe |
Model Number: | HCWHEF01 |
Certification: | calibration certificate (cost additional) |
Place of Origin: | China |
MOQ: | 1 set |
Price: | Negotiatable |
Payment Terms: | T/T |
Supply Ability: | 1 set /month |
Delivery Time: | 45 days |
Packaging Details: | plywood |
Product name: | Storage Water Heater Appliance Performance Test Lab |
Standard: | IEC 60379, GB 21519 |
relative air-humidity: | not exceeding 85% |
ambient temperature: | θamb of 20 ± 2 °C |
Water temperature fluctuation: | θC of 15 ± 2 °C |
Test room size: | 6000*4000*2600mm |
Test station: | 6 stations |
Water temperature range: | 10-65 °C |
Company Info. |
Guangzhou HongCe Equipment Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
Storage Water Heater Appliance Performance Test Lab With 6 Stations
Standard:
IEC 60379 Methods for measuring the performance of electric storage water-heaters for household purposes.
GB 21519 Minimum allowable values of energy efficiency and energy efficiency grades for electrical storage water heaters.
Equipment system composition:
Test room: The test room has strict temperature and humidity requirements and is realized by computer room air conditioner.
Sample mounting bracket: 2pcs, installed in the test room, arranged on both sides, each test bracket has 3 test stations.
Water supply room: include 2 water storage tanks, and constant temperature and constant pressure water supply line pipe.
Control cabinet: It is the data collection, data processing and control center of the system. Appliance Performance Test Lab
Mounting of the water-heater:
Wall-mounted water-heaters are mounted on a panel situated at least 150 mm from any structural wall.
They are positioned so that there is a clear space of at least 250 mm above and below the heater and at least 700 mm at the sides and front.
Floor-mounted water-heaters are placed on the floor or on any stand supplied with them. A false floor may be used to facilitate measurements.
Water-heaters for building-in are built in according to the manufacturer's instructions.
Parameter:
Test room size | 6000*4000*2600mm |
Test room temperature | 20 ± 2 °C |
Test room humidity | <85% |
Sample mounting bracket | 2PCS |
Test station | 6 stations |
Water tank | 2PCS |
Water temperature range | 10-65 °C |
Water supply line pipe | 2 channels |
Water pressure range | 0.1-0.5Mpa. Appliance Performance Test Lab |