| Sign In | Join Free | My benadorassociates.com | 
              
  | 
      
| Categories | Fire Truck Parts | 
|---|---|
| Brand Name: | CXFIRE | 
| Model Number: | CAFS | 
| Certification: | CCC, CE, EN, NFPA | 
| Place of Origin: | China | 
| MOQ: | 1 Unit | 
| Price: | USD30000-USD80000 | 
| Payment Terms: | T/T, L/C, D/A, D/P | 
| Supply Ability: | 1000 units per year | 
| Delivery Time: | 3-6 months | 
| Packaging Details: | Standard Export Package and Delivery by Ship or Air | 
| Application: | Mounted on Fire Trucks | 
| Mixed liquid flow rate: | 550-3500 L/min. | 
| Fire nozzle spraying distance: | 25 Meters | 
| Roof monitor spraying distance: | 40 Meters | 
| Water Pump: | 1200-3600 L/min. Flow Rate | 
| Air Compressor: | 5400-22000L/min. 37-160Kw | 
| Foam Mixing Ratio: | 0.1%-6% | 
| Foam Pump: | 60L/min.-180L/min. | 
| Company Info. | 
| Sichuan Chuanxiao Fire Trucks Manufacturing Co., Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
1. CAFS-60/6000 Compressed Air Foam Fire Extinguishing System for Fire Trucks
| Model | CAFS-60/6000 | 
| Flow Rate and Spray Performance | 1. When outputting compressed air foam (CAF), the rated pressure is 0.75Mpa, and the rated mixed liquid flow rate is 600 L/min; 2. The maximum mixed liquid flow rate is 850L/min; 3. The spraying distance of the fire nozzle is 24 meters; 4. The spraying distance of fire monitors is 40 meters.  | 
| Water Pump | 1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds. 2. Rated flow: 3600L/min; Rated pressure: 1Mpa.  | 
| Air Compressor | 1. The maximum flow is 5400L/min@0.7Mpa, the maximum power is 37KW; 2. The maximum working pressure is 1.5Mpa; 3. The cooling method is water-cooled, with over-temperature automatic protection device.  | 
| Foam Mixing Ratio Unit | 1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %; 2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 10L/min. The system has three pumps combined into a pump group, and the total flow is 30L/min.  | 
| Electric Control Unit | Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus. | 
2. CAFS-900 Compressed Air Foam Fire Extinguishing System for Fire Trucks
| Model | CAFS-900 | 
| Flow Rate and Spray Performance | 1. When outputting compressed air foam (CAF), the rated pressure is 0.75Mpa, and the rated mixed liquid flow rate is 550 L/min; 2. The maximum mixed liquid flow rate is 900L/min; 3. The spraying distance of the fire nozzle is 24 meters; 4. The spraying distance of fire monitors is 40 meters.  | 
| Water Pump | 1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds. 2. Rated flow: 1200L/min; Rated pressure: 1Mpa.  | 
| Air Compressor | 1. The maximum flow is 5400L/min@0.7Mpa, the maximum power is 37KW; 2. The maximum working pressure is 1.5Mpa; 3. The cooling method is water-cooled, with over-temperature automatic protection device.  | 
| Foam Mixing Ratio Unit | 1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %; 2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 10L/min. The system has three pumps combined into a pump group, and the total flow is 30L/min.  | 
| Electric Control Unit | Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus. | 
3. CAFS-1200 Compressed Air Foam Fire Extinguishing System for Fire Trucks
| Model | CAFS-1200 | 
| Flow Rate and Spray Performance | 1. When outputting compressed air foam (CAF), the rated pressure is 0.8Mpa, and the rated mixed liquid flow rate is 1050 L/min; 2. The maximum mixed liquid flow rate is 1200L/min; 3. The spraying distance of the fire nozzle is 25 meters; 4. The spraying distance of fire monitors is 40 meters.  | 
| Water Pump | 1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds. 2. Rated flow: 3600L/min; Rated pressure: 1Mpa.  | 
| Air Compressor | 1. The maximum flow is 8400L/min@0.7Mpa, the maximum power is 55KW; 2. The maximum working pressure is 1.5Mpa; 3. The cooling method is water-cooled, with over-temperature automatic protection device.  | 
| Foam Mixing Ratio Unit | 1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %; 2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 20L/min. The system has three pumps combined into a pump group, and the total flow is 60L/min.  | 
| Electric Control Unit | Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus. | 
4. CAFS-MK3500 Compressed Air Foam Fire Extinguishing System for Fire Trucks
| Model | CAFS-MK3500 | 
| Flow Rate and Spray Performance | 1. When outputting compressed air foam (CAF), the rated pressure is 0.8Mpa, and the rated mixed liquid flow rate is 3000 L/min; 2. The maximum mixed liquid flow rate is 3500L/min; 3. The spraying distance of the fire nozzle is 25 meters; 4. The spraying distance of fire monitors is 45 meters.  | 
| Water Pump | 1. The vacuum degree of the water pump is greater than 85%, When the suction depth is 7 meters, the water diversion time is less than 60 seconds. 2. Rated flow: 3600L/min; Rated pressure: 1Mpa.  | 
| Air Compressor | 1. The maximum flow is 22,000L/min@0.7Mpa, the maximum power is 160KW; 2. The maximum working pressure is 1.3Mpa; 3. The cooling method is water-cooled, with over-temperature automatic protection device.  | 
| Foam Mixing Ratio Unit | 1. Fully automatic foam ratio mixing control device, one-key switch of 1%, 3%, 6%, three foam ratio preset values, and can adjust the foam ratio from 0.1% to 6%, the adjustment accuracy is 0.1 %; 2. The working pressure range of the foam pump is 0.1Mpa-1.2Mpa. The rated continuous flow of a single pump is 20L/min. The system has nine pumps combined into a pump group, and the total flow is 180L/min.  | 
| Electric Control Unit | Composed of a 32-point programmable logic controller and a 7-inch programmable operating screen, the programming controller devices are connected by CAN bus. | 
5. Company Reference Pictures
 
 
                                 
                             |