| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Handheld Digital Multimeter | 
|---|---|
| Brand Name: | CHX | 
| Model Number: | CHX-DM033 | 
| Certification: | CE, RoHS | 
| Place of Origin: | CHINA | 
| MOQ: | 10pc | 
| Price: | Negotiation | 
| Payment Terms: | T/T, Western Union,Paypal,L/C | 
| Supply Ability: | 50000pcs/month | 
| Delivery Time: | 5-35days | 
| Packaging Details: | 1pcs/gift box, 30~50pcs/ctn; package size: 10X5X3cm; gross weight:0.500kg | 
| Model: | CHX-DM033 | 
| Frequency: | 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz | 
| Duty Cycle: | 0.1% - 99% | 
| Temperature: | -20 to 1000°C, -4 to 1832°F | 
| DC Voltage: | 6V/60V/600V | 
| Working Temperature: | -10~50℃ | 
Hot-selling Digital Anemometer Wind Temperature Meter Wind Tester Anemometer
Function selection
1) In the voltage range, press "FUNC" key, will be in the AC
voltage, DC voltage cycle between the switch.
2) In the resistor, diode, buzzer file, press the "SEL" button,
will be in the resistance, on-off detection, diode three file cycle
switch.
3) In the frequency, duty cycle file, press the "FUNC" key, will be
in the frequency, duty cycle between the switch.
4) In the temperature range, press the "FUNC" key, will be in
degrees Celsius and Fahrenheit cycle switch.
5) In the current file, press "FUNC" key, will be in the AC
current, DC current cycle between the switch
backlight and lighting
1) During the measurement, if the ambient light is too dark, the
reading is difficult, press the " " button for more than 2 seconds,
turn on the backlight and the lights, and turn off automatically
after about 15 seconds.
2) During this period, if the " " button for more than 2 seconds
will manually turn off the backlight and lighting.
Backlight and lighting of the luminous body for the LED, the
working current is large, although the instrument has a timer
circuit (timing time of about 15 seconds), but often use the
backlight and lighting will shorten the battery life, so
unnecessary Of the circumstances, should be used as little as
possible backlight.
Technical indicators
Ambient temperature: 23 ± 5 ℃ Relative humidity: <75%
3.2.1 True rms zero input
3.2.1.1 The measurement of sine wave signal, the use of true RMS
measurement method than the traditional average response method
error is small.
3.2.1.2 True RMS The instrument can accurately measure the sine
wave signal, but if it is on the AC function, the instrument may
display 1 to 50 if the measured signal is not input (shorted at the
AC voltage range and the input terminal) Word between a reading.
These deviations are normal. Within the specified measuring range,
they do not affect the accuracy of the multimeter to measure
alternating current.
3.2.1.3 True RMS requires that the input signal reach a certain
level for measurement. Therefore, the AC voltage and current range
is specified between 2% and 100% of full scale.
3.2.2 DC voltage
| Range | Resolution | Accuracy | 
| 6V | 0.001V | ±(0.5% of reading + 5 words) | 
| 60V | 0.01V | |
| 600V | 0.1V | ±(0.8% of reading + 5 words) | 
- Input impedance: 10MΩ
- Maximum input voltage: 600V DC or 600V AC (rms)
Note:
In the small voltage range, the pen is not connected to the circuit
under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high
sensitivity, does not affect the actual measurement results.
3.2.3 AC voltage
| Range | Resolution | Accuracy | 
| 6V | 0.001V | ±(0.8% of reading + 3words) | 
| 60V | 0.01V | |
| 600V | 0.1V | ±(1.0% of reading + 10words) | 
- Input impedance: 10MΩ
- Maximum input voltage: 600V AC (RMS) or 600V DC
- Frequency range: 40 ~ 1000Hz True RMS
Note:
In the small voltage range, the pen is not connected to the circuit
under test, the instrument may have beating the reading,
This is normal, this is because the instrument caused by high
sensitivity, does not affect the actual measurement results.
3.2.4 Alternating current
| Range | Resolution | Accuracy | 
| 600.0uA | 0.1uA | ±(1.5% of reading +10words) | 
| 6000uA | 1uA | |
| 60.00mA | 0.01mA | |
| 600.0mA | 0.1mA | |
| 6A | 0.001A | ±(2.5% of reading +10words) | 
| 10A | 0.01A | 
- Overload protection: mA range fuse (self-recovery fuse 200mA /
250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous
measurement time is not longer than 15 seconds, after the
measurement to stop the current measurement for more than 1 minute.
- Frequency response: 40Hz ~ 1000Hz True RMS.
3.2.5 DC
| Range | Resolution | Accuracy | 
| 600.0uA | 0.1uA | ±(1.0% of reading +5words) | 
| 6000uA | 1uA | |
| 60.00mA | 0.01mA | |
| 600.0mA | 0.1mA | |
| 6A | 0.001A | ±(2.0% of reading +10words) | 
| 10A | 0.01A | 
- Overload protection: mA range fuse (self-recovery fuse 200mA /
250V)
10A range without insurance
- Maximum input current: mA: 600mA DC or AC rms;
10A: 10A DC or AC rms;
When the measured current is greater than 5A, the continuous
measurement time is not longer than 15 seconds, after the
measurement to stop the current measurement for more than 1 minute.
3.2.6 Frequency
| Range | Resolution | Accuracy | 
| 9.999Hz | 0.001Hz | ±(1.0% of reading +3words) | 
| 99.99Hz | 0.01Hz | |
| 999.9Hz | 0.1Hz | |
| 9.999kHz | 0.001kHz | |
| 99.99KHZ | 0.01kHZ | |
| 999.9KHZ | 0.1KHZ | |
| 9.999MHZ | 0.001MHZ | 
- Overload protection: 250V DC or AC (rms)
- Input voltage range: 600mV ~ 10V AC (with the measured frequency
increases, the input voltage should also increase)
3.2.7 Duty cycle
| Range | Resolution | Accuracy | 
| 0.1 – 99.9% | 0.1% | ± 3.0% | 
- Frequency response: 10 ~ 10MHz
- Input voltage range: 600mV ~ 10VAC (with the measured frequency increases, the input voltage should also increase)
- Maximum input voltage: 250V AC (rms)
Resistance
| Range | Resolution | Accuracy | 
| 600W | 0.1W | ±(0.8% of reading +3words) | 
| 6kW | 0.001kW | |
| 60kW | 0.01kW | |
| 600kW | 0.1kW | |
| 6MW | 0.001MW | ±(1.2% of reading +3words) | 
| 60MW | 0.01MW | 
- Open circuit voltage: approx. 1.0V
- Overload protection: 250V DC or AC (rms)
Transistor test
| Range | Description | Test Conditions | 
| hFE | The display reads the approximate value of hFE(0~1000) | Base current of about 10uA; Vce about 2.8V | 
Capacitance
| Range | Resolution | Accuracy | 
| 9.999nF | 0.001nF | ±(4.0% of reading +3words) | 
| 99.99nF | 0.01nF | |
| 999.9nF | 0.1nF | |
| 9.999mF | 0.001mF | |
| 99.99mF | 0.01mF | |
| 999.9mF | 0.1mF | |
| 9.999mF | 0.001mF | ±(5.0% of reading +3words) | 
| 99.99mF | 0.01mF | Not calibrated | 
- Overload protection: 250V DC or AC (rms)
Temperature test
| Range | Accuracy | Resolution | 
| -20℃-300℃ | ±(1.0%+4d) | 1℃ | 
| 301℃-1000℃ | ±(1.9%+5d) | 1℃ | 
| -4℉-600℉ | ±(1.2%+6d) | 1℉ | 
| 601℉-1832℉ | ±(1.9%+6d) | 1℉ | 
- Overload protection: 250V DC or AC (rms)
|   | 
 600uA 6000uA Handheld Digital Multimeter AC DC True Rms Zero Input
                                                                                    
                        
                        
                        
                                                            600uA 6000uA Handheld Digital Multimeter AC DC True Rms Zero Input
                                                    
                        
                     6MW 60MW High Resistance Multimeter 999.9μF 9.999mF 99.99mF
                                                                                    
                        
                        
                        
                                                            6MW 60MW High Resistance Multimeter 999.9μF 9.999mF 99.99mF
                                                    
                        
                     999.9KHz 9.999MHz Handheld Digital Multimeter 0.700Kg RoHS approved
                                                                                    
                        
                        
                        
                                                            999.9KHz 9.999MHz Handheld Digital Multimeter 0.700Kg RoHS approved
                                                    
                        
                     10MΩ 10A AC DC Digital Multimeter 600V 999.9KHz 9.999MHz
                                                                                    
                        
                        
                        
                                                            10MΩ 10A AC DC Digital Multimeter 600V 999.9KHz 9.999MHz
                                                    
                        
                     LCD Display Digital Autorange Multimeter 233g Overload Protection
                                                                                    
                        
                        
                        
                                                            LCD Display Digital Autorange Multimeter 233g Overload Protection
                                                    
                        
                     0.1 Resolution Handheld Digital Multimeter 178.5*56*30.5mm
                                                                                    
                        
                        
                        
                                                            0.1 Resolution Handheld Digital Multimeter 178.5*56*30.5mm
                                                    
                        
                     6MW 60MW Digital Display Multimeter 10MΩ Input Impedance
                                                                                    
                        
                        
                        
                                                            6MW 60MW Digital Display Multimeter 10MΩ Input Impedance
                                                    
                        
                     DC 1000V AC 750V Handheld Digital Multimeter LED Torch Backlight Function
                                                                                    
                        
                        
                        
                                                            DC 1000V AC 750V Handheld Digital Multimeter LED Torch Backlight Function
                                                    
                        
                     200Ω 2kΩ Digital Volt Ohm Meter 233g With Backlight Function
                                                                                    
                        
                        
                        
                                                            200Ω 2kΩ Digital Volt Ohm Meter 233g With Backlight Function
                                                    
                        
                     100mF Handheld Digital Multimeter AC DC 60MΩ 190×90×50mm
                                                                                    
                        
                        
                        
                                                            100mF Handheld Digital Multimeter AC DC 60MΩ 190×90×50mm