| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Current Transducers |
|---|---|
| MOQ: | 100 |
| Payment Terms: | T/T |
| Delivery Time: | 1-12 weeks |
| Packaging Details: | Original packing |
| Rated measuring current IPN: | 1000A |
| Measuring range IPM: | ±2100A |
| Power supply voltage VC: | DC±(15~24)×(1±10%)V |
| Current consumption IC (@±24V): | ≤±35mA+ISN |
| Rated measurement output ISN: | 333.33mA |
| Turns ratio: | 1:3000 |
| Basic error δi(@IPN,TA=25℃): | ≤±0.4% |
| Linearity δL(@IPN,TA=25℃): | ≤±0.1% |
product manual
NACL-1000B-S5/SP1 magnetic balance Hall current sensor is suitable for accurate measurement of AC, DC, and pulse current isolation. The primary side and the secondary side are completely insulated during measurement.
| product advantages | Applications | Reference standard |
| High precision | AC Inverter AC | GB/T 25119-2010 EN50178 EN50155 |
| Good linearity | Private server motor drive | |
| Low temperature drift | Battery powered | |
| Broadband | Converter/Inverter | |
| Quick response | UPS/SVG |
| Main electrical parameters (@±IPN, TA = 25℃) | |
| Rated measuring current IPN | 1000A |
| Measuring range IPM | ±2100A |
| Power supply voltage VC | DC±(15~24)×(1±10%)V |
| Current consumption IC (@±24V) | ≤±35mA+ISN |
| Rated measurement output ISN | 333.33mA |
| Turns ratio | 1:3000 |
| Load resistance RM | @±15V, ±1000A: 0Ω~21Ω(70℃) 0Ω~19.5Ω(85℃) @±15V, ±1500A: 0Ω~10Ω(70℃) @±24V, ±1000A: 8.5Ω~48.5Ω(70℃) 10Ω~54Ω(85℃) @±24V, ±2100A: 10Ω~14Ω(70℃) |
| Accuracy-dynamic parameters | |
| Basic error δi(@IPN,TA=25℃) | ≤±0.4% |
| Linearity δL(@IPN,TA=25℃) | ≤±0.1% |
| Zero output current IO (@IP=0, TA = 25℃) | ≤±0.5mA |
| Zero temperature drift IOT | ≤±0.8mA |
| Response time TR (90% of IPN&di/dt> 50 A/µS) | ≤1µS |
| General data | |
| Working temperature Ta | -40~+85℃ |
| Storage temperature Ts | -45~+90℃ |
| Weight m | ≤850g |
| Insulation withstand voltage | |
| Withstand voltage | 3.8kV |
|