Armoured 6.8mm Mineral Insulated Electric Heating Cable

Categories Mineral Insulated Heating Cable
Brand Name: MICH
Model Number: MOISAEHC
Certification: ISO9001
Place of Origin: China
MOQ: 1 meter
Price: USD0.5-USD5 per meter
Payment Terms: L/C, T/T
Supply Ability: 20 million meters per year
Delivery Time: in one month
Packaging Details: plywood crates
Sheath: armoured
Function: Heating
Application: industrial use
Diameter: 2 mm
Cable Length: in Meter
Power: in Watt
Vottage: Volt
Unit Weight: Up to 184 kg/km
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Armoured 6.8mm Mineral Insulated Electric Heating Cable

Magnesium Oxide Insulated Slender Armored Electric Heating Cable (Sheathed heating cable, mineral insulated heating cable) is made of metal protection tube, inorganic insulation (e.g., magnesium oxide, alumina, etc.), good performance nickel and chromium alloy resistance wire or other metal or metal alloy conductors. It possesses good properties of anti-pressure, anti-vibration, flexible, energy saving, impervious, resistant to radiation, explosion-proof, safe and reliable, easy installation, high mechanical strength, long life and so on. It has been widely used in aerospace, nuclear power, petroleum, chemical, natural gas, military industry, machinery, electricity, energy and other industrial sectors for heating, heat preservation, heat tracing,Heating and heat preservation of gas and fluid, heating and tracing of container pipelines, etc.


The highest heating temperature of armoured heating cable produced is 860℃.


The cable is composed of a continuous seamless metal sheath, one or more heating wires and a tightly compacted magnesium oxide insulation layer, as shown in the figure.


Armour heating element is composed of heating cable in the middle section, cold cable at both ends, connector and terminal, as shown in the figure below, which can be easily connected to power supply.


In addition, heating cable can be made into different shapes and different power heating elements (single core, double core etc, diameter, height, power according to user requirements).


Cable Structure

Application


Nuclear industryconstruction -- asphalt heating
Metal manufacturing industry- low melting point alloy meltingtank/vessel heating
Shell heating for the extruderHeat tracing for high temperature industrial piping
anticoagulation and viscosity reduction of process mediaAll kinds of industrial electric heaters

Specification

Heating cable instruction code


MI SS-B 16K6560/60/2520/220/E1

NO. 1 2 3 4 5 6 7


No.Instruction
1Sheath materialStainless steel
2structure of cable componentsshown in table 1
3cable codesshown in table 2, 3 and 4
4length of heating cableIn meter
5Heating cable powerIn Watt
6heating cable voltageIn Volt
7heating cable voltageSee table 5

Cable Code

1 6 K 6560

No 1 2 3 4


Serial NO.Instruction
1core number1 or 2
2Voltage grade3=300V, 6=600V
3conductor materialsK,N,C
4cold resistance ×10006560=6.56Ω/m×1000

Table 1 Structure of Cable Element

Table 2 Heating Cable Specification (600V Single Core)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
16C2.16.80.0021130184.2
16C3.45.90.0034173138.7
16C5.35.30.0053214111.9
16C8.54.80.008526191.8
16C134.30.01332573.7
16C214.00.02137663.8
16K405.80.04179164.7
16K505.40.05206140.1
16K605.20.06222126.7
16K804.80.08261106.8
16K1004.70.1200100.0
16K1204.50.1220090.2
16K1606.50.1620077.7
16K2005.90.2200110.0
16K2505.30.2521592.1
16K4004.70.428074.0
16K5004.50.530066.2
16N6304.30.6318594.1
16N10003.91.023091.3
16N16003.61.627088.2
16N25003.42.530069.8
16N28003.42.830076.0
16N33003.43.330068.9
16N40003.24.035068.5
16N52003.25.235068.2
16N63003.26.335055.5
16N100003.21035041.7

Table 3 Heating Cable Specification (600V Double Cores)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
26K8.411.80.008443636.1
26K13.49.80.013463433.7
26K218.80.02178340.7
26K348.00.03494275.2
26K547.10.054119213.6
26K856.40.085147171.2
26K1306.00.13167148.6
26K1807.90.1896273.3
26K2607.40.26110235.4
26K3606.80.36130196.6
26K5006.40.5100172.1
26K6505.90.65100145.6
26K10005.71.0100134.1
26K13006.21.3100161.5
26K20005.82.0100139.8
26K33005.43.3100119.5
26N46005.84.6100139.0
26N80005.48.0100119.2
26N130005.013.0100101.3
26N270004.827.010092.6
26N400004.640.010084.9
26N600004.460.010077.5
26N720004.272.010070.6

Table 4 Heating Cable Specification (300V Double Cores)


Cable CodeDiameterNominal resistance at +20Maximum manufacturing lengthUnit weight
mmΩ/mmkg/km
23K2105.20.21222118.5
23K3004.80.326199.4
23K4004.80.426197.7
23K4804.80.4826196.5
23K6504.60.6528487.8
23K10004.11.010069.3
23K13003.81.310059.3
23K20005.02.0100105.3
23K24004.82.410096.2
23K30004.63.010087.8
23N46004.84.610096.8
23N75004.67.510087.4
23N112004.411.210079.2
23N140004.214.010072.0
23N180003.618.010052.9
23N260003.626.010052.5
23N400003.440.010046.6
23N500004.050.010064.2
23N600003.660.010052.0
23N720003.472.010046.4

Note:

The resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

If not specified, the sheath material is based on SS 321;

For the use of 660V voltage occasions, please contact our company professionals.


Table 5 terminal specifications


Model: A, D, EModel: B
Maximum Voltage (V)Maximum Current (A)Terminal SpecificationMaximum Current (A)Terminal Specification
60015E220E1
60020E225E2
60030E340E2
60050E370E2
60070E3100E3

Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

Note 2: the length of cold end cable with standard configuration is 2 meters. If increase or decrease of length required, please contact our professional personnel.


Corresponding reference table between the output power and sheath temperature

Anticorrosive specification

MaterialApplication
SulfateNot Recommend
Hydrochloric acidNot Recommend
Hydrofluoric acidNot Recommend
PhosphateNot Recommend
CarbonateAccording to the real Data
Organic acidApplicable at any condition
Alkali metalAcceptable
Sea waterNot Recommend
ChlorideNot Recommend

Explosion-proof instructions

MISS series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to A, B, C (C1D2) level of explosion-proof electrical equipment.