Sign In | Join Free | My benadorassociates.com
benadorassociates.com
Products
Search by Category
Home > Ventilation Fans >

Thermal Power 61297m3/H Air Circulation Fan Blower Mineral Powder Sintering

Categories Power Plant Fan
Brand Name: SIMO
Model Number: SIMO Blower 9-03
Certification: CE, ISO9001:2008,TUV
Place of Origin: Henan China
MOQ: 1 Set
Price: Negotiable
Payment Terms: T/T, L/C, Payment Term Is Negotiable
Supply Ability: 500 Sets Per Month
Delivery Time: 15-35 Days
Packaging Details: Export Wooden Case Packing, Steel pallet Packing
Voltage: 380V/415V/440V/660V/6KV/10KV
Power source: Three Phase AC Motor
Motor: SIEMENS/ABB/By your demand
Bearing cooling: Air cooling or Circulating Water cooling
Lubrication: Oil bath lubrication
Medium: Clean air/Dusty air
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Thermal Power 61297m3/H Air Circulation Fan Blower Mineral Powder Sintering

Mineral Powder Sintering Thermal Power Air Circulation Fan Blower


Application


Centrifugal fan is applied in industrial boiler, (centrifugal fan can be applied in industrial boiler,) it also can be applied in industrial kilns, blast furnace, Industrial waste heat recovery device, Electrolytic aluminium production line air purification system and other industrial work environment.

According to fan parameters you need, SIMO can make centrifugal blower fan technical solution for you. So please provide air capacity, pressure range, medium temperature, voltage and other requirements, more details will help us design suitable technical solution for you.


Centrifugal fan is applied in industrial boiler, (centrifugal fan can be applied in industrial boiler,) it also can be applied in industrial kilns, blast furnace, Industrial waste heat recovery device, Electrolytic aluminium production line air purification system and other industrial work environment.

According to fan parameters you need, SIMO can make centrifugal blower fan technical solution for you. So please provide air capacity, pressure range, medium temperature, voltage and other requirements, more details will help us design suitable technical solution for you.


Introduction Of Centrifugal Fan


When the fan is working, the airflow enters the blade space from the fan axially, and then rotates with the impeller under the drive of the impeller; on the other hand, it increases energy under the action of inertia, leaves the impeller along the radius, and does work by the centrifugal force generated. The fan is called a centrifugal fan.


The main components of the centrifugal fan are: impeller, casing, coupling and shaft. The impeller is the main work component that generates wind pressure and transfers energy; the casing is mainly used to introduce gas and exhaust gas, and at the same time convert part of the kinetic energy of the gas into pressure energy; the coupling is used to connect the motor and the fan to transmit torque;the shaft is installed with the motor through a coupling and the impeller is fixed.


The centrifugal fan is mainly composed of an impeller and a casing. The impeller of the small fan is directly mounted on the motor, and the large fan is connected with the motor through a coupling or a pulley.


Centrifugal fans generally use single-side air intake and use single-stage impellers; those with large flow can be air-intaken on both sides and use two back-to-back impellers, which are also called double-suction centrifugal fans.


The principle of gas discharge: When the gas between the blades of the centrifugal fan rotates, the kinetic energy obtained by the centrifugal force is discharged from the periphery of the impeller, guided by the volute-shaped casing, so that it flows to the outlet of the ventilator, thereby being in the center of the impeller. Negative pressure is formed in the part, so that the external airflow continuously flows in and supplements, so that the fan can discharge the gas.


Technical data


Series no.9-03 seriesFeature selection
Normalanti-corrosionwear-resistingHigh temperatureanti-explosionRemarks
PerformanceImpeller diameter400-1800mm
Rotation speed≤4000rpm
Pressure range1581-10587Pa
Flow range90.6-61297㎥/h
StructureBlade typeForward
Impeller supportSWSI(Single Width, Single Inlet), DWDI(Double Width, Double Inlet), Overhung type
Lubrication methodOil bath lubrication, grease lubrication, lubrication oil stationCan be specified
Cooling methodAir cooling, Water cooling, Oil coolingCan be specified
Driven modeDirect driven, Coupling driven, Belt drivenCan be specified
Gas compositionGas temperatureNormalCustomer requestCustomer request≥250℃Customer request
gas characteristicClean gasCorrosive gasParticulate dustHigh temperature gasFlammable gas, explosive gas
System configurationMotor brandChinese famous brand, ABB, Siemens, WEG etcCan be specified
ImpellerHigh quality carbon steelFRP, Stainless steel, Rubber LiningWear-resistant layer or wear-resistant liner, ceramic patchHigh temperature high quality alloy steelFRP, Aluminum alloyCan be specified
Air inlet coneHigh quality carbon steelFRP, Stainless steel, Rubber LiningHigh quality carbon steelHigh quality carbon steelHigh quality carbon steelCan be specified
CasingHigh quality carbon steelFRP, Stainless steel, Rubber LiningHigh quality carbon steelHigh quality carbon steelHigh quality carbon steelCan be specified
Air damperHigh quality carbon steelFRP, Stainless steel, Rubber LiningHigh quality carbon steelHigh quality carbon steelHigh quality carbon steelCan be specified
Main shaftHigh strength carbon steel, Alloy structural steelCan be specified
BearingZWZ, SKF, FAG, NSKCan be specified
Bearing housingCast iron
Foundation boltsGB799-1988
Option partsSystem base frame, Protective screening, Silencer, Inlet & Outlet flexible connections, Inlet & Outlet counter flange, Air damper, Electric actuator, Shock absorber, Diaphragm coupling, Fluid coupling, Motor rain cover, Temperature sensor, Vibration sensor, Soft starter, Inverter, Special Electrical Motor, System monitoring Instrument.

FAQ


1. What parameters need to be provided when you design the Heat Dissipation Power Plant Blower Fan?

Answers: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.

If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.


2. How about your company’s pre-sales service and after-sales service?

Answers: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.

After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.


3. Does your company have qualifications?

Answers: SIMO Blower has obtained ISO 9001-2008, CE, BV certifications and so on.


Buy Thermal Power 61297m3/H Air Circulation Fan Blower Mineral Powder Sintering at wholesale prices
Send your message to this supplier
 
*From:
*To: Xinxiang SIMO Blower Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0