| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Fisher Gas Regulator |
|---|---|
| Brand Name: | Fisher |
| Model Number: | R622H-DGJ |
| Place of Origin: | Made In China |
| MOQ: | Negotiation |
| Price: | Negotiation |
| Payment Terms: | T/T, Western Union, MoneyGram |
| Supply Ability: | 500sets Every Month |
| Delivery Time: | 3-8 work-days |
| Packaging Details: | 1set packed in one carton ,each carton size is 22*15.5*15.5cm,1.6kg each one. |
| Name: | Fisher R622H-DGJ LPG Gas Regulator |
| End Connetion: | 3/4" NPT*3/4" NPT |
| Inlet Pressure: | 250psi |
| Spring Range: | 8 to 12PSI |
| Orifice Size: | 7/32" |
| Flow Rate: | 30m³/h |
| Company Info. |
| Suzhou Ephood Automation Equipment Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
Emerson Fisher R622H-DGJ LPG Gas Regulator
Fisher R600 Series second-stage regulators are Underwriters Laboratories (UL) listed designed to reduce the outlet pressure from a first-stage regulator, usually 10 psig / 0,69 bar to 11-inches w.c. / 27 mbar, in domestic installations. Screened drip-lip vent has standard orientation over the inlet with other orientations available. Fishersecond-stage regulators are painted palm green for easy identification. The second-stage R600 Series regulators are equipped with stainless steel inlet screen to reduce the amount of debris entering the regulator.
Type R622 is designed for Two-Stage domestic applications up to 1 400 000 BTU per hour / 15,8 SCMH. The Type R622’s time proven design and corrosion resistant materials, provide a recommended replacement life of 20 years. Type R622 contains a high performance relief valve and a large 3/4-inch screened vent to limit downstream pressure to less than 2 psig / 0,14 bar in an overpressure situation as required by NFPA 58.
The relief valve design exceeds the industry standard by limiting the downstream pressure to 2 psig / 0,14 bar even in a double failure situation when used with a Type R622H or R122H First Stage Regulator. The Type R622 is adjustable from 9 to 20-inches w.c. / 22 to 50 mbar. For easy system checks, the Type R622 has 1/8-inch NPT built-in gauge taps, orificed to a No. 54 drill size, on both the upstream and downstream sides. This regulator also features a large 3/4-inch drip-lip vent design.
Features
Compact Design
High Capacity
Protective Inlet Screen
Internal Relief
Light Weight
Inlet and Outlet Pressure Gauge Taps
Specifications
Body Sizes and End Connection Styles
3/4"FNPT*3/4"FNPT
Maximum Allowable Inlet Pressure
250psig / 17.2 bar
Outlet Pressure Ranges
8-12psi
Pressure Registration
Internal
Temperature Capabilities
-20° to 160°F / -29° to 71°C
| NO. | Model | Type | Orifice | Spring | Setting Pressure | Inlet Size | Outlet Size |
| 1 | R622-BCF | 2nd stage | 7/32 | 9-13IN W.C | 11"W.C. | 1/2" | 1/2" |
| 2 | R622-BCC | 2nd stage | 7/32 | 6-9IN W.C | 7"W.C. | 1/2" | 1/2" |
| 3 | R622-BCG | 2nd stage | 7/32 | 13-20IN W.C | 14"W.C. | 1/2" | 1/2" |
| 4 | R622-CFF | 2nd stage | 7/32 | 9-13IN W.C | 11"W.C. | 1/2" | 3/4" |
| 5 | R622-DFF | 2nd stage | 7/32 | 9-13IN W.C | 11"W.C. | 3/4" | 3/4" |
| 6 | R622-DFG | 2nd stage | 7/32 | 13-20IN W.C | 14"W.C. | 3/4" | 3/4" |
| 7 | R622H-DGJ | High Pressure | 7/32 | 8-12 PSI | 10 PSI | 3/4" | 3/4" |
| 8 | R632-BCF | Two-stage | 7/32 | 9-13IN W.C | 11"W.C. | 1/4" | 1/2" |

|