| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Water Quality Sensor | 
|---|---|
| Brand Name: | KACISE | 
| Certification: | CE,ISO | 
| Place of Origin: | Shaanxi, China (Mainland) | 
| MOQ: | 0-100 | 
| Price: | Negotiable | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 100 | 
| Delivery Time: | 5 working days after payment | 
| Packaging Details: | carton or customers requests available | 
| Output: | Support RS-485, MODBUS protocol | 
| Measuring range: | 0~20mg/L | 
| Response time: | 10 sec | 
| Protection level: | IP68 | 
| accurate: | 1% | 
| temperature range: | 0 ~ 50℃ | 
| Power: | DC6-12V,Current<50mA | 
| Size: | Φ26*177.5 mm | 
| Model Number: | KBU601 | 
| Company Info. | 
| Xi'an Kacise Optronics Co.,Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
12mm Fermentation Special Fluorescence Method Dissolved Oxygen Sensor
Description
12mm fermentation fluorescence method dissolves oxygen sensor, adopts international leading fluorescence life technology, RS-485 output, supports MODBUS protocol. Compared with the traditional polarographic oxygen sensor, it has many technical advantages such as no preheating, no electrolyte, no oxygen consumption, no generation, high precision, anti-interference, maintenance-free, quick response, and more environmental protection. It is resistant to acid and alkali and can be sterilized at high temperature. It meets CIP disinfection standards and steam sterilization standards.

Measuring principle
The Fluorescence Dissolved Oxygen Analyzer is based on the quenching principle of the specific fluorescence of the specific substance in physics. The blue light from a light-emitting diode (LED) is irradiated onto the fluorescent material on the inner surface of the fluorescent cap, and the fluorescent material on the inner surface is excited to emit red light, and the phase difference between the red light and the blue light is detected, and the internal calibration is performed. The values are compared to calculate the concentration of oxygen molecules, and the final values are automatically compensated by temperature and pressure.
Feature
● Suitable for steam sterilization, high temperature sterilization
and CIP cleaning
● No film, no electrolyte, no polarization
● Does not consume oxygen, is not affected by flow rate
● Built-in temperature sensor, automatic temperature compensation
● Small drift, fast response and more accurate measurement
● Free of maintenance, long application period
Technical Specifications
| product | Online fluorescence dissolved oxygen sensor | |
| principle | Ultraviolet fluorescence method | |
| Measuring range | 0~20mg/L | |
| Response time | 10 sec | |
| accurate | 1% | |
| Protection level | IP68 | |
| Deepest depth | Underwater 60 meters | underwater 10 meters | 
| temperature range | 0 ~ 50℃ | |
| Output | Support RS-485, MODBUS protocol | |
| Power supply | DC 5~12V, current <50mA | |
| size | Φ26*177.5 mm | |
| Probe cable length | 10 m, customizable 5 m, 15 m and 30 m cable | |
| Fluorescent cap life | 1 year | |
| Maximum working pressure | 6bar | |
| product material | 304 food grade stainless steel | |
|   | 
 Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmission
                                                                                    
                        
                        
                        
                                                            Intelligent Water Quality Sensor Fiber Optic Chlorophyll Sensor RS485 Transmission
                                                    
                        
                     Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing Diameter
                                                                                    
                        
                        
                        
                                                            Aquaculture Fluorescence Dissolved Oxygen Sensor High Accuracy 22mm Casing Diameter
                                                    
                        
                     Accurate 10% 	Water Quality Sensor RS485 Output Multi Parameter
                                                                                    
                        
                        
                        
                                                            Accurate 10% 	Water Quality Sensor RS485 Output Multi Parameter
                                                    
                        
                     Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
                                                                                    
                        
                        
                        
                                                            Environmentally Friendly COD Sensor / Kws-100 Cod Measurement Instrument
                                                    
                        
                     NH4-N Ammonia Nitrogen Water Quality Sensor KWS-200 PH Range 4-10
                                                                                    
                        
                        
                        
                                                            NH4-N Ammonia Nitrogen Water Quality Sensor KWS-200 PH Range 4-10
                                                    
                        
                     90° Scattered Light Aquaculture Industry Water Turbidity Sensor 0 - 1000NTU Measuring Range
                                                                                    
                        
                        
                        
                                                            90° Scattered Light Aquaculture Industry Water Turbidity Sensor 0 - 1000NTU Measuring Range
                                                    
                        
                     Radial Installation Manometer Pressure Gauge Pressure Monitoring Storage
                                                                                    
                        
                        
                        
                                                            Radial Installation Manometer Pressure Gauge Pressure Monitoring Storage
                                                    
                        
                     Electromagnetic flowmeter for measuring liquid flow 0.6-4.0MPa pressure with accuracy 0.5%
                                                                                    
                        
                        
                        
                                                            Electromagnetic flowmeter for measuring liquid flow 0.6-4.0MPa pressure with accuracy 0.5%
                                                    
                        
                     Support MODBUS and RS-485 output digital oil in water sensors support MODBUS and CE certification with resolution 0.1pp
                                                                                    
                        
                        
                        
                                                            Support MODBUS and RS-485 output digital oil in water sensors support MODBUS and CE certification with resolution 0.1pp
                                                    
                        
                     Dissolved Oxygen Sensor Water Quality Sensor IP68 Grade For Shrimp Farm
                                                                                    
                        
                        
                        
                                                            Dissolved Oxygen Sensor Water Quality Sensor IP68 Grade For Shrimp Farm