| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Battery Testing Equipment | 
|---|---|
| Brand Name: | Sinuo | 
| Model Number: | SNBT4008FA-20V30A | 
| Certification: | Calibration Certificate (Cost Additional) | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | Customized | 
| Payment Terms: | T/T, L/C, Western Union, MoneyGram | 
| Supply Ability: | 10 Sets Per Month | 
| Delivery Time: | 1 Month | 
| Packaging Details: | Plywood | 
| Voltage Range: | 100mV~20V | 
| Min. Discharge Voltage: | 2.5V | 
| Cutoff Current: | 0.06A | 
| Current Range: | 150mA~30A | 
| Accuracy: | ± 0.1% of FS | 
| Channels Per Unit: | 8 | 
| Company Info. | 
| Sinuo Testing Equipment Co. , Limited | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
IEC62133-1 20V 30A Charge Discharge Capacity Lithium Ion Battery
And Cell Test Equipment
Overview:
This battery charge discharge testing equipment meets the
requirements of battery and cell pulse charge and discharge test,
DC internal resistance (DCIR) test, cycle life (Cycle Life) test,
rate charge and discharge test. This testing equipment comes with
unique software, which can run on computer to achieve romote
control and minitor.
This series of battery testing systems are widely used in various
research institutions, universities and power battery
manufacturers.
Standards & Clauses:
Conforms to IEC62133-1/-2:2017 clause 7.1, 7.2.1, 7.3.8, 7.3.9,
IEC62133-1/-2:2012 clause8.1.1, 8.1.2, 8.2.1, 8.3.6, 8.3.7
IEC60086-4 clause 6.5.8 6.5.9 IEC60622, IEC60623, IEC 60086-1,
IEC61951, IEC61960
Technical Parameters:
| Project index | Parameter index | |
|---|---|---|
| Input Power | AC 220V ±10% / 60Hz (can be customized) | |
| resolution | AD:16bit;DA:16bit | |
| Input Resistance | ≥1MΩ | |
| Input Power | 6684W | |
| Channel Control Feature | Constant current source and constant voltage source adopt independent double closed loop structure | |
| Channel Control Mode | Independent control | |
| Voltage | Voltage Range Per Channel | 100mV~20V | 
| Minimum discharge voltage | 2.5V | |
| Accuracy | ± 0.1% of FS | |
| Constant voltage cutoff current | 0.06A | |
| Stability | ± 0.1% of FS | |
| Current | Current Range Per Channel | 150mA~30A | 
| Accuracy | ± 0.1% of FS | |
| Stability | ± 0.1% of FS | |
| Power | Per Channel Output Power | 600W | 
| Stability | ± 0.2% of FS | |
| Time | Current Response Time | Maximum current rise time 20m S | 
| Step Time Range | ≤(365*24 )hour/step, | |
| Data Recording | Record Condition | Time△t: 100ms | 
| Voltage△U: 40mV | ||
| Current△I: 60mA | ||
| Record Frequency | 10Hz | |
| Charge | Charge Mode | Constant current charging, constant voltage charging, constant current and constant voltage charging, constant current and constant voltage of the battery pack, constant power charging | 
| Cutoff Condition | Voltage, current, relative time, capacity, -ΔV | |
| Discharge | Discharge Mode | Constant current discharge, constant power discharge, constant resistance discharge | 
| Cutoff Condition | Voltage, Current, Relative Time, Capacity, -ΔV | |
| Pulse Mode | Charge mode | Constant current mode, Constant power mode | 
| Discharge mode | Constant current mode constant power mode | |
| Cutoff conditions | Time, line number | |
| Min. pulse width | 500ms | |
| Number of pulse | Single pulse step supports 32 different pulses | |
| Continuous switching of charge and discharge | A pulsed step can achieve continuous switching from charge to discharge | |
| Cutoff condition | Voltage, relative time | |
| DCIR Test | Supports custom point retrieval for DCR calculations | |
| Cycle | Loop Measure Range | 1~65535 times | 
| Max Steps Per Loop | 254 | |
| Nested Loop | Nested loop Function, Max Support 3 Layers | |
| Protection | Software Protection | 
 | 
| 
 | ||
| 
 | ||
| Voltage and current detection sampling | Four-wire connection | |
| Noise | <85dB | |
| Noise | <85dB | |
| Database | MySQL Database | |
| A Means of Communication of Upper Machine | TCP/IP Protocol | |
| Data Output | EXCEL2003/2010, TXT | |
| Communication Interface | Ethernet Port | |
| Per Unit Main Channels No. | 8 | |
| Dimensions | 12U chamber, W*D*H:600*600*1260(mm) | |
| Fixture | To be determined | |
Equipment Working Environment:
| Project index | Parameter index | 
|---|---|
| Working Temperature Range | 0℃~40℃ | 
| Storage Temperature Range | -10℃~50℃ | 
| Working Environment Relative Humidity Range | ≤70% RH (No condensation) | 
| Storage Environment Relative Humidity Range | ≤80% RH(No condensation) | 
The number of channels, voltage range, current range and etc. can
be customized according client's specific requirements and
specimen. Please email or call to Sinuo for further assistance.
|   | 
 IEC 62133 Stainless Steel Ingestion Gauge for Small Cell and Battery Safety Information
                                                                                    
                        
                        
                        
                                                            IEC 62133 Stainless Steel Ingestion Gauge for Small Cell and Battery Safety Information
                                                    
                        
                     Discharge Capacity Battery Testing Equipment For 20V 200A Car Lead Acid Storage Battery
                                                                                    
                        
                        
                        
                                                            Discharge Capacity Battery Testing Equipment For 20V 200A Car Lead Acid Storage Battery
                                                    
                        
                     5V 6A Li-ion Batteies and Cells Life Analyzer High Precision Dual Range Capacity Test Equipment
                                                                                    
                        
                        
                        
                                                            5V 6A Li-ion Batteies and Cells Life Analyzer High Precision Dual Range Capacity Test Equipment
                                                    
                        
                     20V 100A Automotive Battery Testing Equipment Charge Discharge Capacity Test Independent 4 Channels
                                                                                    
                        
                        
                        
                                                            20V 100A Automotive Battery Testing Equipment Charge Discharge Capacity Test Independent 4 Channels
                                                    
                        
                     High Voltage High Current EV Power Battery Detection System for Automotive Large Battery Packs
                                                                                    
                        
                        
                        
                                                            High Voltage High Current EV Power Battery Detection System for Automotive Large Battery Packs
                                                    
                        
                     15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer
                                                                                    
                        
                        
                        
                                                            15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer
                                                    
                        
                     IEC 62133-2 Battery Testing Equipment 2017 Secondary Cells / Batteries Forced Internal Short Circuit Test
                                                                                    
                        
                        
                        
                                                            IEC 62133-2 Battery Testing Equipment 2017 Secondary Cells / Batteries Forced Internal Short Circuit Test
                                                    
                        
                     IEC60086-4 Lithium Ion Battery and Cell Safety 1000A External Short Circuit Testing Equipment
                                                                                    
                        
                        
                        
                                                            IEC60086-4 Lithium Ion Battery and Cell Safety 1000A External Short Circuit Testing Equipment
                                                    
                        
                     Charge Discharge Battery Testing Equipment Explosion Proof Safety Stainless Steel Chamber
                                                                                    
                        
                        
                        
                                                            Charge Discharge Battery Testing Equipment Explosion Proof Safety Stainless Steel Chamber
                                                    
                        
                     IEC 62133 Li-ion Battery and Cell Free Fall 1 M Pneumatic Drop Motor Lifting Test Equipment
                                                                                    
                        
                        
                        