| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Energy Efficiency Lab | 
|---|---|
| Brand Name: | Sinuo | 
| Model Number: | SN3310 | 
| Certification: | Calibration Certificate (Cost Additional) | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | Customized | 
| Payment Terms: | L/C, T/T, Western Union, MoneyGram | 
| Supply Ability: | 5 Sets Per Month | 
| Delivery Time: | 2 Months | 
| Packaging Details: | Plywood | 
| Power: | ≤5KW | 
| Voltage: | 0-300V | 
| Head: | 0-50m | 
| Rotating Speed: | 0-3000rpm | 
| Flow Rate: | 0-200M³/h | 
| Pipe Diameter: | Ф25/40/50 | 
| Company Info. | 
| Sinuo Testing Equipment Co. , Limited | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Comprehensive Performance Testing System for 5KW Household Appliance Water Pumps
Overview:
This comprehensive pump performance test system is suitable for testing various types of household appliances' pumps; the system is mainly composed of main control cabinet, flow sensor, pressure sensor and instruments. The pump motor’s voltage, current, power, flow, rotating speed, pressure, head and other data can be tested; and H-Q curve, P-Q curve, η-Q curve and (NPSH) r-Q curve can be drawn according to the data collected by the test project.
The system complies with: international standards ISO9906-2012/ national standards GB3216-2005, GB12785-2002, GB6245-2006, GB9064, machinery industry standards JB8092-96, JB5118-2001, JB8091-98, JB6434-92.
Techinical Parameters and Requirements:
| Basic parameter requirement | Medium | □Clear water | |
| Test pump type | □ Centrifugal pump □ Mixed flow pump □ Axial flow pump □ Vortex pump □ Screw pump □ Well submersible pump □ Sewage submersible pump □ Small submersible pump □ Fire pump □ Magnetic pump | ||
| Voltage(V) | 0-300V | ||
| power(KW) | 0-5KW | ||
| Rotating speed(r/min) | 0-3000rpm | ||
| Flow rate(M³/h) | 0-200M³/h | ||
| Pump head(m) | 0-50m | ||
| System Requirements | water circulatory system | □Open style | |
| Pipe diameter(mm) | Ф25/40/50 | ||
| Flow regulation | □Manual □Electric | ||
| Axis power flow mode | □Electrometry | ||
| Test items | Electrical measuring method | □ No-load test □ Load/performance test □ Vibration test □ Noise test □ Cavitation test | |
| System accuracy | Conforms to: International Standard ISO9906-2012/National Standards GB3216-2005, GB12785-2002, GB6245-2006, GB9064, Machinery Industry Standards JB8092-96, JB5118-2001, JB8091-98, JB6434-92 □ Level 1 / Level B □ Level 2 / Level C | ||
| Acquisition parameters | AC voltage, current, power, frequency, motor speed, inlet pressure, outlet pressure, flow, etc. | ||
| Pump performance analysis and calculation of main parameters, curves | Head, flow, pump efficiency, unit efficiency, shaft power, NPSH; flow at rated head, head at rated flow, actual measured intersection of pump performance; measured flow deviation, head deviation, pump efficiency deviation, etc. | ||
| Data Acquisition Analysis Mode | Computer automatic collection, analysis, printing, database management, Windows98/2000/XP interface | ||
System Diagram:

Software Interface:

(English language is available)
Sinuo can design and customize comprehensive performance testing system for all kinds of water pumps, such as household appliance's water pumps, industry water pumps, car engine cooling water pumps, washing pumps, aquarium pumps and etc. Please contact us for more information.
|   | 
 IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber
                                                                                    
                        
                        
                        
                                                            IEC 60879-2019 Energy Efficiency Lab Ceiling Fans Environmental Test Chamber
                                                    
                        
                     Performance Analysis Energy Efficiency Lab For Clothes Washing Machines
                                                                                    
                        
                        
                        
                                                            Performance Analysis Energy Efficiency Lab For Clothes Washing Machines
                                                    
                        
                     Energy Efficiency Testing Room For DOE Qualified Ceiling Fans UL Standard Ceiling Fan Laboratory
                                                                                    
                        
                        
                        
                                                            Energy Efficiency Testing Room For DOE Qualified Ceiling Fans UL Standard Ceiling Fan Laboratory
                                                    
                        
                     Temp. 76±2°F Humidity 50% Energy Efficiency Test Lab Of ENERGY STAR Qualified Ceiling Fans
                                                                                    
                        
                        
                        
                                                            Temp. 76±2°F Humidity 50% Energy Efficiency Test Lab Of ENERGY STAR Qualified Ceiling Fans
                                                    
                        
                     Energy Efficiency Testing Laboratory For Electric Water Storage Heaters 4 / 6 / 8/ 10 Stations
                                                                                    
                        
                        
                        
                                                            Energy Efficiency Testing Laboratory For Electric Water Storage Heaters 4 / 6 / 8/ 10 Stations
                                                    
                        
                     Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test
                                                                                        
                                                        
                        
                        
                        
                                                            Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test
                                                    
                        
                     IEC 60456 Washing Machines Performance Testing Room Energy Efficiency Enviromental Lab
                                                                                    
                        
                        
                        
                                                            IEC 60456 Washing Machines Performance Testing Room Energy Efficiency Enviromental Lab
                                                    
                        
                     Electric Rice Cookers Energy Efficiency Lab 2 Test Benches 6 Black Corners
                                                                                    
                        
                        
                        
                                                            Electric Rice Cookers Energy Efficiency Lab 2 Test Benches 6 Black Corners
                                                    
                        
                     Water Efficiency Grades Energy Efficiency Lab For Reverse Osmosis Drinking Water Treatment Purifiers
                                                                                    
                        
                        
                        
                                                            Water Efficiency Grades Energy Efficiency Lab For Reverse Osmosis Drinking Water Treatment Purifiers
                                                    
                        
                     10 ~ 3000m³/H 0~ 200Pa Air Volume Measurement System For A.C. Electric Ventilating Fans
                                                                                    
                        
                        
                        
                                                            10 ~ 3000m³/H 0~ 200Pa Air Volume Measurement System For A.C. Electric Ventilating Fans