| Sign In | Join Free | My benadorassociates.com | 
              
  | 
      
| Categories | UPS power supply | 
|---|---|
| Brand Name: | ECO | 
| Model Number: | ECO-RT | 
| Certification: | CE | 
| Place of Origin: | China | 
| MOQ: | 1 | 
| Price: | USD 250 | 
| Payment Terms: | Western Union, MoneyGram, T/T | 
| Supply Ability: | 1000month | 
| Delivery Time: | 7 | 
| material: | metal | 
| input voltage: | 110V | 
| output voltage: | 110V | 
| Socket: | IEC/US/UK/Euro | 
| Model item | S1K (R)  | S1K (R)S  | S2K (R)  | S2K (R)S  | S3K (R)  | S3K (R)S  | S6K  | S6K (R)S  | S10K  | S10K (R)S  | ||
| Rated power | 1000VA/800W | 2000VA/1600W | 3000VA/2400W | 6kVA/5.4kW | 10kVA/9kW | |||||||
| AC Input | Input system | Single phase (L/N+PE) | ||||||||||
| Nominal voltage | HV: 208/220/230/240Vac LV:100/110/120/127Vac  | |||||||||||
| Frequency | 50/60Hz | |||||||||||
| Voltage range | HV: 90~300VAC±5VAC LV: 60-145Vac±3VAC  | |||||||||||
| Frequency range | (40~70)±0.5Hz | |||||||||||
| Input power factor | >0.99 | |||||||||||
| Bypass Voltage Range | HV: 115~285VAC×(1±3%) LV: 80~140VAC×(1±3%)  | |||||||||||
Battery Input  | Nominal Voltage | 24V | 36V | 48V | 72V | 72V | 96V | 144V | 192V | 192V/240V | ||
| Battery Capacity & Quantity | 12V/7AH x 2pcs  | External | 12V/7AH x 4pcs  | External | 12V/7AH x 6pcs  | External | 12V/7AH x 12pcs | External | 12V/7AH x16/20pcs  | External | ||
| Backup Time | Half loaded≥8minutes, Full loaded ≥3minutes(standard)  | Half loaded≥6minutes, Full loaded ≥2minutes(standard)  | ||||||||||
| Battery charger time | Charger to 90% battery capacity in 5 hours(standard) Dependent on the capacity of external batteries (long backup time) | |||||||||||
AC Output  | Output system | Single phase (L/N+PE) | ||||||||||
Inverter Mode Output voltage  | HV:208/220/230/240Vac±2% LV:100/110/120/127Vac±2%  | |||||||||||
| Waveform | Sine Wave THD<3% (linear load) THD<7% (nonlinear load)  | Sine Wave THD<2% (linear load) THD<5% (nonlinear load)  | ||||||||||
| Output frequency | 50/60±4Hz (Sync mode) 50/60Hz±1% (Fix Freq. mode)  | |||||||||||
| Dynamic voltage transient range | <9% | <6% | ||||||||||
| Dynamic Transient Recovery | < 100ms | < 60ms | ||||||||||
| Overload capability | 105~125%≥ 60s,126~150%≥30s The recover point is 70% | |||||||||||
| Crest Ratio | 3:1 | |||||||||||
| Transfer time | Battery <-> Line Mode :0ms | |||||||||||
| Communications | RS232 RS485(optional), Dry contact(optional) | |||||||||||
| Alarm Function | AC/DC input under abnormal, overload condition and Inverter problems | |||||||||||
| Protection Function | AC input or output above or below the range of voltage, overload, over temperature and short circuit protection | |||||||||||
| Noise | <50dB | <55dB | ||||||||||
                                 
                             |