Brand Name: CN CABLE
Model Number: RZ1-K
Certification: CE
Place of Origin: Henan
MOQ: 1000meters
Payment Terms: L/C, T/T
Delivery Time: 20days after payment
Packaging Details: Roll, wooden drum
conductor: Class 5 flexible plain copper
Insulation: XLPE
Sheath: LSZH
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

XLPE Insulation LV Power Cable RZ1-K LSZH Cable 600 / 1000V Voltage Rating

RZ1-K LSZH Cable use for where fire, smoke emission and toxic fumes create a potential threat to life and equipment


Application
For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. A flexible power and control cable designed for fixed applications. Manufactured with flexible conductors in order to facilitate installations with sinuous courses.


Standards
UNE 21123-2, 60502-1, EN 50265, IEC 60332-1


Conductor: Class 5 flexible plain copper conductor to BS EN 60228:2005 (previously BS6360)
Insulation: XLPE (Cross-Linked Polyethylene) Type DIX-3to HD603
Sheath: LSZH (Low Smoke Zero Halogen) Polyolefine to UNE 21123
Sheath Color: Green
Voltage Rating: 600/1000V
Temperature Rating: -15°C to +90°C
Minimum Bending Radius: 5 x overall diameter
Core Identification:
1 Core: Black
2 Cores: Blue, Brown
3 Cores including Earth Core: Blue, Brown, Green/Yellow
3 Cores: Brown, Black, Grey
4 Cores including Earth Core: Brown, Black, Grey, Green/Yellow
4 Cores: Brown, Black, Grey, Blue
5 Cores including Earth Core: Brown, Black, Grey, Green/Yellow, Blue


Technical Data

No. of Cores x Nominal Cross Sectional Area
# x mm²
Nominal Thickness of Insulation
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/Km
RZ1-K LSZH Cable - 1 Core
1 x 2.50.76.254
1 x 4.00.76.770
1 x 6.00.77.390
1 x 10.00.78.2133
1 x 16.00.79.2189
1 x 25.00.911.0284
1 x 35.00.912.1381
1 x 50.01.013.8517
1 x 70.01.115.7712
1 x 95.01.117.6923
1 x 120.01.219.21165
1 x 150.01.421.51446
1 x 185.01.623.91748
1 x 240.01.726.92280
1 x 300.01.829.62829
1 x 400.02.033.83731
1 x 500.02.237.44776
1 x 630.02.442.76276
RZ1-K LSZH Cable - 2 Cores
2 x 1.50.78.290
2 x 2.50.79.2120
2 x 4.00.710.3161
2 x 6.00.711.3211
2 x 10.00.713.2316
2 x 16.00.714.9450
RZ1-K LSZH Cable - 3 Cores including Earth Core
3 x 1.50.78.9108
3 x 2.50.79.8144
3 x 4.00.711.0198
3 x 6.00.712.1263
3 x 10.00.714.3405
RZ1-K LSZH Cable - 3 Cores
3 x 16.00.716.4593
3 x 25.00.921.3975
3 x 35.00.924.11319
3 x 50.01.027.81812
3 x 70.01.130.82463
RZ1-K LSZH Cable - 4 Cores including Earth Core
4 x 1.50.79.7129
4 x 2.50.710.7175
4 x 4.00.712.0243
4 x 6.00.713.4328
4 x 10.00.715.7505
RZ1-K LSZH Cable - 4 Cores
4 x 16.00.718.2749
4 x 25.00.924.11245
4 x 35.00.926.31671
4 x 50.01.031.32313
4 x 70.01.136.13204
4 x 95.01.140.24126
4 x 120.01.244.65245
4 x 150.01.449.86573
4 x 185.01.656.18050
4 x 240.01.764.510695
RZ1-K LSZH Cable - 5 Cores including Earth Core
5 x 1.50.710.4153
5 x 2.50.711.6213
5 x 4.00.713.2298
5 x 6.00.714.7403
5 x 10.00.717.2624
5 x 16.00.720.2931
5 x 25.00.925.61555
5 x 35.00.929.32076
5 x 50.01.034.52878
No. of Cores x Nominal Cross Sectional Area
# x mm²
Nominal Thickness of Insulation
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/Km
RZ1-K LSZH Cable - 1 Core
1 x 2.50.76.254
1 x 4.00.76.770
1 x 6.00.77.390
1 x 10.00.78.2133
1 x 16.00.79.2189
1 x 25.00.911.0284
1 x 35.00.912.1381
1 x 50.01.013.8517
1 x 70.01.115.7712
1 x 95.01.117.6923
1 x 120.01.219.21165
1 x 150.01.421.51446
1 x 185.01.623.91748
1 x 240.01.726.92280
1 x 300.01.829.62829
1 x 400.02.033.83731
1 x 500.02.237.44776
1 x 630.02.442.76276
RZ1-K LSZH Cable - 2 Cores
2 x 1.50.78.290
2 x 2.50.79.2120
2 x 4.00.710.3161
2 x 6.00.711.3211
2 x 10.00.713.2316
2 x 16.00.714.9450
RZ1-K LSZH Cable - 3 Cores including Earth Core
3 x 1.50.78.9108
3 x 2.50.79.8144
3 x 4.00.711.0198
3 x 6.00.712.1263
3 x 10.00.714.3405
RZ1-K LSZH Cable - 3 Cores
3 x 16.00.716.4593
3 x 25.00.921.3975
3 x 35.00.924.11319
3 x 50.01.027.81812
3 x 70.01.130.82463
RZ1-K LSZH Cable - 4 Cores including Earth Core
4 x 1.50.79.7129
4 x 2.50.710.7175
4 x 4.00.712.0243
4 x 6.00.713.4328
4 x 10.00.715.7505
RZ1-K LSZH Cable - 4 Cores
4 x 16.00.718.2749
4 x 25.00.924.11245
4 x 35.00.926.31671
4 x 50.01.031.32313
4 x 70.01.136.13204
4 x 95.01.140.24126
4 x 120.01.244.65245
4 x 150.01.449.86573
4 x 185.01.656.18050
4 x 240.01.764.510695
RZ1-K LSZH Cable - 5 Cores including Earth Core
5 x 1.50.710.4153
5 x 2.50.711.6213
5 x 4.00.713.2298
5 x 6.00.714.7403
5 x 10.00.717.2624
5 x 16.00.720.2931
5 x 25.00.925.61555
5 x 35.00.929.32076
5 x 50.01.034.52878


Class 5 flexible Copper Conductors for Single Core and Multi-Core cables

Nominal Cross Sectional Area
mm2
Maximum Diameter of Wires in Conductor
mm
Maximum Resistance of Conductor at 20ºC
Plain Wires
ohms/Km
2.500.267.9800
4.000.314.9500
6.000.313.3000
10.000.411.9100
16.000.411.2100
25.000.410.7800
35.000.410.5540
50.000.410.3860
70.000.510.2720
95.000.510.2060
120.000.510.1610
150.000.510.1290
185.000.510.1060
240.000.510.0801
300.000.510.0641
400.000.510.0486
500.000.610.0384
630.000.610.0287


Electrical Characteristics
Current Carrying Capacity (amperes) and Resistance Values (ohms per kilometre)

No. of Cores x Nominal Cross Section Area
# x mm²
Current Carrying CapacityVoltage Drop
V/A/Km
In Air
Amps
In Earth
Amps
RZ1-K LSZH Cable - 1 Core
1 x 2.5292917.700
1 x 4.0403711.000
1 x 6.053467.320
1 x 10.074614.230
1 x 16.0101792.680
1 x 25.01351011.730
1 x 35.01691221.230
1 x 50.02071440.860
1 x 70.02681780.603
1 x 95.03282110.457
1 x 120.03832400.357
1 x 150.04442710.286
1 x 185.05103040.235
1 x 240.06073510.178
1 x 300.07033960.142
1 x 400.08234640.108
1 x 500.09465250.085
1 x 630.010885960.064


RZ1-K LSZH Cable [Continued]

No. of Cores x Nominal Cross Section Area
# x mm²
Current Carrying CapacityVoltage Drop
V/A/Km
In Air
Amps
In Earth
Amps
2 x 1.5262634.000
2 x 2.5363420.400
2 x 4.0494412.700
2 x 6.063568.450
2 x 10.086734.890
2 x 16.0115953.100
RZ1-K LSZH Cable - 3 Cores including Earth Core
3 x 1.5262634.000
3 x 2.5363420.400
3 x 4.0494412.700
3 x 6.063568.450
3 x 10.086734.890
RZ1-K LSZH Cable - 3 Cores
3 x 16.0100792.680
3 x 25.01271011.730
3 x 35.01581221.230
3 x 50.01921440.860
3 x 70.02461780.603
RZ1-K LSZH Cable - 4 Cores including Earth Core
4 x 1.5232229.500
4 x 2.5322917.700
4 x 4.0423711.000
4 x 6.054467.320
4 x 10.075614.230
RZ1-K LSZH Cable - 4 Cores
4 x 16.0100792.680
4 x 25.01271011.730
4 x 35.01581221.230
4 x 50.01921440.860
4 x 70.02461780.603
4 x 95.02982110.457
4 x 120.03462400.357
4 x 150.03992710.286
4 x 185.04563040.235
4 x 240.05383510.178
RZ1-K LSZH Cable - 5 Cores including Earth Core
5 x 1.5232229.500
5 x 2.5322917.700
5 x 4.0423711.000
5 x 6.054467.320
5 x 10.075614.230
5 x 16.0100792.680
5 x 25.01271011.730
5 x 35.01581221.230
5 x 50.01921440.860


Short Circuit Current Carrying Capacities
The maximum short-circuit current that a cable can withstand depends on the time of reaction of the protection elements installed in the line. The maximum current-carrying capacity in a short-circuit accident, for a specific type of cable, is the result of multiplying the cross-section of the cable for the values shown in the table below.

Time s0.10.20.30.51.01.52.02.53.0
Amps/mm24523202612021431171019083

RZ1-K LSZH Cable [Continued]
Correction Factors
For air temperature other than 30°C

Air Temperature20°C25°C30°C35°C40°C45°C50°C55°C60°C
Factor1.081.041.000.960.910.870.820.760.71

For ground temperature other than 20°C

Ground Temperature10°C15°C20°C25°C30°C35°C40°C45°C50°C
Factor1.071.041.000.960.930.890.850.800.76

For soil thermal resistivity, which depends on damp , other than 2.5°K • m/W

Moisture degree of soilVery DampSlightly DampSlightly DryDryVery Dry
Thermal Resistivity (°K • m/W)1.01.52.02.53.0
Factor1.181.101.051.000.96
Buy XLPE Insulation LV Power Cable RZ1-K LSZH Cable 600 / 1000V Voltage Rating at wholesale prices
Send your message to this supplier
 
*From:
*To: CN Cable Group Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0