| Brand Name: | HOLD-ONE |
| Certification: | ASTM B-231,B232,B399, ICEA S-76-47 |
| Place of Origin: | China |
| MOQ: | 500 m |
| Price: | 0.19-10.99USD/m |
| Payment Terms: | L/C, D/A, D/P, T/T |
| Supply Ability: | 1000km per Month |
| Delivery Time: | 15 Days |
| Packaging Details: | Wooden Drum/ Steel Drum |
| Phase Conducto: | Aluminium |
| Neutral or messenger: | aluminium alloy conductor and compacted circular stranded |
| Application: | Overhead Power Transmission Lines |
| Insulation: | XLPE Or PVC |
| Voltage: | 0.6/1 KV |
| Company Info. |
| Qingdao Yilan Cable Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
0.6/1(1.2)kV AL/XLPE(PE) Insulated
Aerial Bundled Cables without Street Lighting Conductor
Description
The aerial Bundled cables designed for overhead distribution lines
have an insulated neutral messenger made of AAAC, which the
insulated aluminium phase conductor are helically wound over it.
Cables are rated at 0.6/1(1.2)kV and conform to IEC60502.
Construction
a)Phase - The phase conductor shall be of H68 Condition aluminium
conductor and compacted circular stranded.
b)Neutral or messenger - The Neutral or messenger conductor shall
be of aluminium alloy conductor and compacted circular stranded.
The phase, neutral conductors shall be extruded with
polyethylene(PE) as insulation.
Schedule of technical particulars
| Phase conductor | |||||||||||
| Nominal cross-sectional area | mm² | 16 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
| Number of cores | 1 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 6 | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 | |
| Nominal insulation thickness | mm | 1 | 1 | 1.2 | 1.2 | 1.4 | 1.4 | 1.6 | 1.6 | 1.8 | 2.0 |
| Diameter of insulated core | mm | 6.8 | 6.8 | 8.5 | 9.5 | 11.2 | 13.0 | 15.1 | 16.6 | 18.4 | 20.6 |
| Max. DC resistance at 20℃ | ohm/km | 1.91 | 1.91 | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 |
| Current rating at still wind, ambient | A | 61 | 61 | 84 | 104 | 129 | 167 | 209 | 246 | 283 | 332 |
| temperature=30℃ | |||||||||||
| Conductor temperature=75℃ | |||||||||||
| Messenger conductor | |||||||||||
| Nominal cross-sectional area | mm² | 25 | 25 | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
| Minimum number of wires | 6 | 6 | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
| Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
| Diameter of insulated core | mm | 8.5 | 8.5 | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
| Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
| Calculated breaking load | kN | 6.4 | 6.4 | 6.4 | 6.4 | 8.9 | 12.1 | 18.0 | 18.0 | 24.2 | 30.8 |
| Completed cable | |||||||||||
| Approx. overall diameter | mm | 15.3 | 19.0 | 23.2 | 25.6 | 30.0 | 34.9 | 40.6 | 44.1 | 49.2 | 54.9 |
| Approx. weight of cable | kg/km | 160 | 290 | 400 | 500 | 680 | 920 | 1270 | 1510 | 1870 | 2340 |
| Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 |
|