| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | 3 Phase Load Bank | 
|---|---|
| Brand Name: | Kaixiang | 
| Model Number: | AC425-2500kW | 
| Certification: | ISO9001 | 
| Place of Origin: | China | 
| MOQ: | 1 set | 
| Price: | negotiable | 
| Payment Terms: | L/C, T/T, Western Union | 
| Supply Ability: | 90 Sets per Month | 
| Delivery Time: | Within 30 working days | 
| Packaging Details: | Container for Load bank | 
| Ambient Temperature: | -10℃~+50℃ | 
| Rated Voltage: | AC425V | 
| Dimensions: | About 4000mm×2350mm×2591mm | 
| Relative Humidity: | ≤95% | 
| Frequency: | 50 HZ | 
| Rated Power: | 2500 kW | 
Power bank 2500 KW AC Electric Load Banks For Testing Generators UPS
Product description
(1) According to the special requirements of users on site, in the agreement the technical
standards of AC425-2500kW Intelligent Load Bank(hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.
(2) The system consists of 1 sets of 2500kW load bank. The resistive power is 2500kW. The System is made up of two parts of measurement and control and load, mainly including the outdoor type dry load, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote controller and PC software and so on.
Technical Parameter
| System Parameter | |
| Rating voltage/frequency | AC 3 phase 4 line, 425V/50Hz | 
| Max Load Power | Resistive Load: 2500kW | 
| Load Resolution | Resistive Load: 21 steps, 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,100kW,200kW, 200kW, 200kW, 200kW, 200kW,200kW, 200kW, 200kW, 200kW, 200kW, 200kW | 
| Power Factor | 1 | 
| Load Tolerance (each step) | ±5% | 
| Load Tolerance (overall) | ±3% | 
| Fan &Control Voltage | External AC 3 phase 4 line,425V/50Hz | 
| Wire Connection | Load bank input——Copper bar (star coupling ”Y”) Control power input——Connector-bar | 
| Communication Interface | RS485,RS232 | 
| Insulation | F | 
| Max Protection Grade | IP54 | 
| Duty Cycle | Continuous | 
| Cooling | Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling | 
| Enclosure | Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door | 
| Internal Lighting | Adequate internal lighting will be provided | 
| Transportation | Hoisting, there are lifting lug in top of casing | 
| Color | Grey RAL7035 or as required | 
| Dimensions | About 6058mm×2350mm×2591mm(L×W×H) | 
| Operating Environment Parameter | |
| Ambient Temperature | -10℃~+50℃ | 
| Relative Humidity | ≤95% | 
| Atmospheric Pressure | 86~106kPa | 
| Brands of Main Components | |
| Contactor | Schneider | 
| Fuse | Miro | 
| PLC | Siemens | 
| Alloy Resistor | (self-developing) | 
| Data Processing Software | (self-developing) | 
Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.
Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.
Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.
Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.
Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.
Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.
Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.
Application
Large generator system testing in ocean engineering, drilling
facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test,
speed characteristic test;
Marine generator overload protection test,parallel operation
test,reverse power and reverse current protection test
|   | 
 Flexible Control Inductive Load Bank Stable Running For Drilling Facilities
                                                                                    
                        
                        
                        
                                                            Flexible Control Inductive Load Bank Stable Running For Drilling Facilities
                                                    
                        
                     3000 KVA 4 Wire 3 Phase Load Bank , Medium Voltage Dry Type AC Load Bank
                                                                                    
                        
                        
                        
                                                            3000 KVA 4 Wire 3 Phase Load Bank , Medium Voltage Dry Type AC Load Bank
                                                    
                        
                     RAL7035 Manual 3 Phase Load Bank 230 V Phase Voltage For Ocean Engineering
                                                                                    
                        
                        
                        
                                                            RAL7035 Manual 3 Phase Load Bank 230 V Phase Voltage For Ocean Engineering
                                                    
                        
                     Blue Resistive Reactive Load Bank F Class With Short Circuit Protection
                                                                                    
                        
                        
                        
                                                            Blue Resistive Reactive Load Bank F Class With Short Circuit Protection
                                                    
                        
                     Container Sealing Capacitive Load Bank , Efficient Detection Automatic Load Bank
                                                                                    
                        
                        
                        
                                                            Container Sealing Capacitive Load Bank , Efficient Detection Automatic Load Bank
                                                    
                        
                     Axial Fan 5000 KW 3 Phase Load Bank Automatic High Performance Container
                                                                                    
                        
                        
                        
                                                            Axial Fan 5000 KW 3 Phase Load Bank Automatic High Performance Container
                                                    
                        
                     2000 KW Full 3 Phase Load Bank , Dry Load Module Resistive Electrical Loads
                                                                                    
                        
                        
                        
                                                            2000 KW Full 3 Phase Load Bank , Dry Load Module Resistive Electrical Loads
                                                    
                        
                     Large 2500 KW Load Bank Cabinet Yellow / Grey With Smoke Fog Protection
                                                                                    
                        
                        
                        
                                                            Large 2500 KW Load Bank Cabinet Yellow / Grey With Smoke Fog Protection
                                                    
                        
                     3 MW Resistive Load Bank Vertical Exhaust Cooling For Generator Load Test
                                                                                    
                        
                        
                        
                                                            3 MW Resistive Load Bank Vertical Exhaust Cooling For Generator Load Test
                                                    
                        
                     14 Steps Gray 3 Phase Load Bank Continuous Working With 254 V Phase Voltage
                                                                                    
                        
                        
                        
                                                            14 Steps Gray 3 Phase Load Bank Continuous Working With 254 V Phase Voltage