| Brand Name: | GE | 
| Model Number: | IC9445B200AB | 
| Place of Origin: | USA | 
| MOQ: | 1 | 
| Price: | negotiable | 
| Payment Terms: | T/T, Western Union,paypal, Western Union | 
| Supply Ability: | 100. Ali. | 
| Delivery Time: | 5-8 work days | 
| Packaging Details: | New in original box | 
| Certification: | dose not supply | 
| Resistance ranges: | 0 to 500 ohms,0 to 3000 ohms | 
| Temperature sensitivity (0° to 60°C) +: | +/–0.004% of reading, +/–1.5µV per °C referred to input | 
| Maximum lead resistance: | 5 ohms per lead | 
| Update Rate:: | 210 ms | 
| Power Consumption:: | 125 mA from +5V bus | 
| No. of channels:: | 4 (3-wire and/or 4-wire RTDs) | 
| Company Info. | 
| Shenzhen Wisdomlong Technology CO.,LTD | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
IC9445B200AB GE FANUC Limit Switch Lever Watertight Standard Contact 2 Circuits
Product Description
| Nominal Rated Voltage: | 120/240 VAC or 125 VDC | 
| Input Voltage Range: | 85 to 264 VAC or 100 to 300 VDC | 
| Input Power: | 90 VA with VAC or 50 W with VDC | 
| Load Capacity: | 30 Watts | 
| Location on Baseplates: | Left most Slot | 
| Communication: | RS 485 Serial Port | 
LED Indicator
The OK LED indicates module status: ▪ On green indicates normal
operation ▪ Flashing green indicates boot mode or update ▪ Flashing
amber indicates self-diagnostic error ▪ Off indicates no 3.3V
backplane power.

Using the Module in Hazardous Locations
▪ WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY
IMPAIR SUITABILITY FOR CLASS I, DIVISION 2;
▪ WARNING - EXPLOSION HAZARD - WHEN IN HAZARDOUS LOCATIONS, TURN
OFF POWER BEFORE REPLACING OR WIRING MODULES.
▪ WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS
POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE
NONHAZARDOUS.
▪ Equipment labeled with reference to Class I, Div. 2, Groups A, B,
C and D, Hazardous Locations is suitable for use in Class I, Div.
2, Groups A, B, C, D or non-hazardous locations only.
▪ Equipment labeled with reference to Class I, Zone 2, Groups A, B,
C and D, hazardous locations is suitable for use in Class I, Zone
2, Groups A, B, C, D or non-hazardous locations only.
▪ Be sure to read the installation instructions provided with the
module and its terminal assembly. These instructions specify the
use of copper conductors and wire gauge and type requirements.