Brand Name: KingPo
MOQ: 1
Place of Origin: China
Certification: ISO 17025 Calibration certificate
Price: To be quoted
Packaging Details: safety box
Delivery Time: 25~30 working days
Payment Terms: 100% TT in advance
Supply Ability: 3~5 units per month
spec: 100V200A
power supply: AC voltage 380V ±10%
frequency: 50Hz ±10%
ambient temp: 0-45°C
Resolution: AD:16bit
channel: 4
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

100V 200A Lithium Battery Testing Equipment Charge Discharge Tester

100V 200A Lithium Battery Testing Equipment Charge Discharge Tester


100V200A Battery Charge-Discharge Tester


RCDS-100V200A

Technical Specification for battrry Charge and Discharge Equipment


Application Scope and Function of Equipment

1. 1Scope of equipment application: Mainly used to include lithium ion batteries, lead acid batteries, nickel cadmium batteries, nickel hydrogen batteries and other batteries in the production or experiment (CircleLifeTesting) and quality control.

1. 2test contents of the support: battery cycle life test, battery capacity test, battery charging characteristics test, battery discharge characteristics test, battery charge-holding capacity test, battery charge-discharge efficiency test, battery overcharge, over-discharge rate tolerance test, etc.

Equipment environmental requirements and technical parameters

Power supply: AC voltage 380V ±10%, frequency:50Hz ±10%

Ambient temperature:0-45°C

Environmental humidity: not greater than 95% R.H (anhydrous vapor condensation)

No strong vibrations, non-corrosive gases and inflammable and explosive gases

Resolution: AD:16bit


Technical parameters

Number

Model

RCDS-100V200A

1

Number of Main Channels

4CH / Rack

2

output power

Maximum power 20kW for channel operation; no time limit

3

output power stability

±(0.1%FS+0.1%RD)

4

Input side power quality

power factor

>99%loaded to capacity

Total harmonic distortion rate

≤5%loaded to capacity

6

Energy consumption parameters

Standard sine wave feedback energy, high efficiency (optimum efficiency 90%)

7

Main Channel Working Mode

Charging: constant current charging CC, constant voltage charging CV, constant current constant voltage charging CCCV, constant current constant voltage charging process conversion needs to achieve no impulse voltage current;

Discharge: constant current discharge CD, constant power amplifier CP, constant resistance discharge CR, constant voltage constant current discharge

pause n.

Keywords Working condition test; Pulse test;

8

Main channel voltage

Single Channel Measurement Range

0.2V-100V, with continuously adjustable intermediate values (wide test range, suitable for various battery module test requirements)

Minimum discharge voltage

7V

precision

±(0.05%FS+0.05%RD)

Resolution

1mV

Main channel current

Single Channel Measurement Range

-200A~+200A

Minimum output current

200mA

precision

±(0.05%FS+0.05%RD)

resolution ratio

1mA

response time

<10ms

apolegamy assist

voltage

Number of channels

32

Measurement range

DC:0-5V

Measurement precision

±(0.05%FS+0.05%RD)

resolution ratio

1mV

apolegamy assist

temperature

number of tracks

4

Measuring Range

﹣50℃~300℃

Accuracy in measurement

±1℃

Resolution ratio

0.1℃

time

Data acquisition resolution

10ms

9

Equipment communication mode

Support LAN communications

Battery BMS communications

Support CAN 2.0A, CAN 2.0B; RS485 communications

Supports DBC import, enables data reading with BMS CAN and participates in process control

10

Control control program

Support power down data protection, support for power failure, manual stop, data file succession testing, online modification of step parameters

Safety protection conditions can be set. Parameters include: voltage lower limit, voltage upper limit, current lower limit, current upper limit temperature upper limit

Auxiliary channel / BMS protection conditions can be set. The parameters can include: voltage upper limit, voltage lower limit, temperature upper limit, temperature lower limit, single cell pressure difference

cycle index

MAX10000

Programmable steps

MAX10000

Loop nesting

Maximum 10 floors

Step Time Range

Unlimited support for h, min, s format

Minimum interval for data recording

Time ≥10ms, voltage ≥0.1% FS, current ≥0.1% FS, and supporting step-by-step setting of recording conditions

Programming Features

Each work step may have one or more exits

11

work pattern

Constant-current charging

Battery pack voltage, time, capacity, electricity, monomer temperature, monomer voltage, cell voltage difference, RSOC,- V up to

Constant-voltage charging

Current, time, capacity, electricity, monomer temperature, monomer voltage, cell voltage difference, RSOC,- V up to

Constant current and constant voltage charging

Current, time, capacity, electricity, monomer temperature, monomer voltage, cell voltage difference, RSOC,- V up to

Shelve

End of time

Constant-current discharge

Battery pack voltage, time, capacity, electricity, cell temperature, cell voltage, cell voltage difference up to

Constant power discharge

Battery pack voltage, current, time, capacity, electricity, cell temperature, cell voltage, cell voltage difference up to

Constant resistance discharge

Battery pack voltage, current, time, capacity, electricity, cell temperature, cell voltage, cell voltage difference up to

12

Data presentation

Circular list

Have cycle serial number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge level average voltage, etc.

List of processes

There are process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc.

Detailed list

There are record number, system time, accumulative time, voltage, current, energy, monomer temperature1--monomer temperature n, monomer voltage 1-- monomer voltage n, monomer voltage extreme difference, etc.

13

Data export

Data can be led into excel, TXT, chart file, can provide charge-discharge curve, capacity decay rate, cycle life curve, charge-discharge voltage, current, capacity-time and other ways of data analysis curve and data list

14

Data save mode

The user can customize the name and the data save path, and the data can be saved by file

15

Type of curve

X coordinates: total time, charge/discharge time/capacity, number of cycles

Y coordinates: total voltage, current, capacity, energy, monomer voltage 1-monomer voltage n, monomer temperature 1-monomer temperature n

16

Input protection

Over-voltage, over-current, lack of phase, over-temperature, protection alarm;

Output protection

Over-voltage, over-current, short-circuit, capacity, temperature, monomer overvoltage, monomer under-voltage protection; without detecting the battery voltage, no output;

Power-off protection

After the external power is cut off, the battery and the equipment are automatically disconnected to avoid the accident caused by re-powering.

Hardware protection

Power off protection, open circuit protection, short circuit protection; battery connection back, fault protection, over-current protection, overvoltage protection, over-temperature protection, hardware overvoltage over-current protection

Short-circuit protection

External short circuit;

Software protection

Power down data protection, call continuation, overvoltage over-discharge protection, over-current protection, capacity protection, over-temperature protection, voltage trend abnormal protection, current trend abnormal protection, current fluctuation abnormal protection, voltage fluctuation abnormal protection, charge voltage rise speed abnormal protection, discharge current drop speed abnormal protection, equipment communication abnormal protection, auxiliary module communication abnormal protection

Alarm function

The hardware has the functions of emergency cutting off switch, automatic shutdown after power off, automatic load connection and disconnection.

17

Cooling-down method

Forced air cooling

18

Sampling terminals

Four-electrode sampling mode, fixture line terminal or other

19

Auxiliary Channel Collection Line

Acquisition cable length adjustable according to actual situation

20

Security classification

Meet EN 60950, GB 4943 requirements

noise

The noise is less than 70dBA, the sound level meter used should meet the requirements of type I in IEC804, and the accuracy should be better than ±0.5dB.

Levels of protection

IP20

Lightning protection

Level 2 lightning protection requirements for GB 17626

21

Maintainability

Modular structure, spare parts available for timely replacement, maintenance, free of charge during the warranty period

22

Software upgrade service

Software upgrade service provided until hardware is incompatible




Device specific advantages

Energy feedback (standard sine wave feedback energy, best efficiency 90%): energy feedback type, charge and discharge two-way are energy-saving, can save a lot of electricity consumption, while saving a lot of energy energy generated by the cost of air conditioning electricity.

CCCV charging: charging process CCCV no gap transition, no any voltage current impact. It can effectively prevent the protection action and the secondary protection action of PCB caused by the peak current of the battery due to the heat concentration of the polar ear depowdering or the micro-short circuit producing the island effect or the overshoot phenomenon.

The current and voltage sampling stability is good and the precision is high: high precision, high dynamic range ADC/DAC unit, high voltage sampling accuracy and good long-term stability.

IDUser management consists of three parts: permission management, role management and user management. The administrator can set administrative permissions for each functional module of the software, and set multiple user IDs according to the permissions of the operator

DL Dynamic Load Protection Function: Effectively protects the battery in the charge and discharge, prevents the battery fire and effectively avoids the current shock caused by the loosening of the connector, and effectively protects the electronic components of the battery from being damaged by the shock current, such as MOSFET, FUSE

Voltage clamp function: During the charging process in the battery protection action or equipment abnormal, the voltage clamp position in the safe voltage to prevent battery or battery pack protection plate damage.

The test step can set the record condition in sections and implement the intelligent data management record.

Support BMS CAN communication function: real-time acquisition of BMS system total voltage, total current, single core voltage, temperature and other data, and CDS voltage and current data to do synchronous comparison, set BMS voltage and current temperature and other data to meet certain conditions, the main channel steps to stop or convert, specific reading information provided by the customer related information.

A custom set of signals is supported. The user can customize the name according to their own requirements and data records. By adding "sub-signal quantity" as the protection parameter, the protection

Parameter can be set multiple, and the result can generate a new decision condition by calculating the operator "maximum value, minimum value, difference value, mean value,-,×," function relation

RCDS-100V200A Technical Specification for battrry Charge and Discharge Equipment 0

File query: can be based on the test date, test channels, keywords and other information search related, and support data batch export

RCDS-100V200A Technical Specification for battrry Charge and Discharge Equipment 1

Appearance and Structure of Equipment

Cabinet


Rack size (W*D*H)

600*800*1980mm

weight

≤300kg

Number of modules

4CH / Rack

Remark: The above picture is for reference only, subject to physical object!

Software Testing InterfaceSoftware Testing InterfaceRCDS-100V200A Technical Specification for battrry Charge and Discharge Equipment 2Setup interfaceRCDS-100V200A Technical Specification for battrry Charge and Discharge Equipment 3Data interfaceRCDS-100V200A Technical Specification for battrry Charge and Discharge Equipment 4Curve alignment interfaceRCDS-100V200A Technical Specification for battrry Charge and Discharge Equipment 5Working condition simulation setup interfaceRCDS-100V200A Technical Specification for battrry Charge and Discharge Equipment 6Working condition simulation data interfaceRCDS-100V200A Technical Specification for battrry Charge and Discharge Equipment 7


Hot Tags: 100v200a battery charge-discharge tester, China, manufacturers, suppliers, factory, custom, wholesale, Torque Wrench Type Test Machine, External Mechanical Impact Tester, IEC60529 IPX5 IPX6 Handheld Jet Nozzle Tester, Digital Push And Pull Force Gauge, Scratched Pin Electric Safety Testing Probes, Thermal Abuse Test Chamber

Buy 100V 200A Lithium Battery Testing Equipment Charge Discharge Tester at wholesale prices
Send your message to this supplier
 
*From:
*To: Dongguan Kingpo Technology Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 