Aurora-10 10.4-inch Multi Parameter patient monitor optional touch screen WIFI connection for hospital
ICU


Patient monitor
Short Description:
◆5 Standard parameters: ECG, NIBP, SpO2, RESP, Temp
◆10.4-inch high resolution industry color TFT LCD display
◆Real time S-T segment analysis, pace-maker detection
Product Detail:

◆Indication of incorrect manipulation and malfunction analysis
◆Patient info input management function
◆Multi-lead ECG waveforms display in phase
◆Large volume of tabular and graphic trends information storage and
easy to recall
◆Capture dynamic waveforms
◆Up to 2.5 hours working capacity of built-in rechargeable lithium
battery
◆Unique accessory management cabinet
Networking capacity
◆Option: EtCO2, 5AH Lithium battery, wireless communication module (WIFI, GPRS),
touch screen, IBP, AG.
Accessories:

Technique parameters
ECG | |
Input | 3/5 wire ECG cable |
Lead section | I II III aVR, aVL, aVF, V |
Gain selection | *0.25, *0.5, *1, *1.2 |
Sweep speed | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s |
Heart rate range | 15-30bpm |
Calibration | ±1mv |
Accuracy | ±1bpm or ±1% (select the bigger data) |
NIBP | |
Test method | Oscillometer |
Philosophy | Adult, Pediatric and Neonate |
Measurement type | Systolic Diastolic Mean |
Measurement parameter | Automatic, Continuous measurement |
Measurement method Manual | mmHg or ±2% |
SPO2 | |
Display Type | Waveform, Data |
Measurement range | 0-100% |
Accuracy | ±3% (between 70%-100%) |
Pulse rate range | 20-300bpm |
Accuracy | ±1bpm or ±2% (select the bigger data) |
Resolution | 1bpm |
2-Temperature (Rectal & Surface) | |
Number of channels | 2 channels |
Measurement range | 0-50℃ |
Accuracy | ±0.2℃ |
Display | T1, T2, ☒T |
Unit | ºC/ºF selection |
Refresh cycle | 1s-2s |
Respiration (Impedance & Nasal Tube) | |
Measurement type | 0-150rpm |
Accuracy | ±1bm or ±5%, select the bigger data |
Resolution | 1rpm |
Packing Information | |
Packing size | 34*34*28cm |
N.W. | 5kg |
G.W. | 6kg |
| Standard configuration |
| Screen |
| Display Type | 10″ color TFT LCD |
| Resolution | 800×600 pixels |
| Waveforms | Up to 7 |
| ECG |
| Input | 3/5 wire ECG cable |
| Lead section | I II III aVR, aVL, aVF, V |
| Gain selection | *0.25, *0.5, *1, *1.2 |
| Sweep speed | 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s |
| Heart rate range | 15-30bpm |
| Calibration | ±1mv |
| Accuracy | ±1bpm or ±1% (select the bigger data) |
| NIBP |
| Test method | Oscillometer |
| Philosophy | Adult, Pediatric and Neonate |
| Measurement type | Systolic Diastolic Mean |
| Measurement parameter | Automatic, Continuous measurement |
| Measurement method Manual | mmHg or ±2% |
| SPO2 |
| Display Type | Waveform, Data |
| Measurement range | 0-100% |
| Accuracy | ±3% (between 70%-100%) |
| Pulse rate range | 20-300bpm |
| Accuracy | ±1bpm or ±2% (select the bigger data) |
| Resolution | 1bpm |
| 2-Temperature (Rectal & Surface) |
| Number of channels | 2 channels |
| Measurement range | 0-50℃ |
| Accuracy | ±0.2℃ |
| Display | T1, T2, ☒T |
| Unit | ºC/ºF selection |
| Refresh cycle | 1s-2s |
| Respiration (Impedance & Nasal Tube) |
| Measurement type | 0-150rpm |
| Accuracy | ±1bm or ±5%, select the bigger data |
| Resolution | 1rpm |
| Optional configuration |
| EtCO2-Plug & Play |
| Measurement type | Side stream |
| Measurement range | 0-10.0%; 0-76mmHg |
| Accuracy | <5.0%, ±0.28kPa; ±2mmHg |
| >5.0%, ±10% |
| 2-IBP (optional) |
| Measurement range | 10~300mmHg |
| Number of channels | 1 or 2 channels |
| Accuracy | ±1mmHg or ±2%, select bigger data |
| Pressure tag | ART, CVT, RVP, LAP, RAP, PAP, ICP, LVP |
| 12 leads ECG (optional) |
| Input | 3/5/10 wires ECG cable |
| Lead section | I, II, III aVR, aVL, aVF, V(V1-V6) |
| Heart rate range | 15-380bpm |
| Calibration | ±1mv |