| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Gas Sensor |
|---|---|
| Brand Name: | CITY |
| Model Number: | 4P-50 4P-50C PM123-000 |
| Place of Origin: | UK |
| MOQ: | 1 |
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
| Supply Ability: | 311/pcs/pre |
| Delivery Time: | 3-5work days |
| Packaging Details: | Canned |
| Price: | Negotiable |
| Gases Detected: | Combustible gases |
| Suitable for: | methane, ethane, propane, |
| Unsuitable for: | higher hydrocarbons, alcohols, |
| Range: | 0-100% LEL |
| Operating Voltage: | 4.25V d.c. |
| Detector Operating Current: | 56±6mA |
| Company Info. |
| ShenzhenYijiajie Electronic Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
Product Description:
4P-50 PM123-000 Combustible Gas Sensor Catalytic Oxidation 100% LEL
Features:
Poison:Resistance
H2S filter lifetime:Output Sensitivity
T90 Response Time:Linear to
Long Term Sensitivity Drift:Long Term Zero Drift
Warranty Period:Combustible gases
Relative Sensitivity
The table below shows the response variation of a 4P-50C
CiTipeL on exposure to a range of gases and vapours at the
same %LEL concentration. The figures are experimentally
derived and expressed relative to the methane signal (=100).
Significantly increased silicone poison resistance
Significantly increased H2S resistance
As with all 4P sensors, excellent shock
resistance, reduced orientation effects and wake
up times
Enhanced version denoted by B prefix to serial
number
Specifications:
| Operating humidity range | 15%rH to 90%rH non-condensing |
| Operating pressure range | Atmospheric pressure ± 20% |
| pressure coefficient | 0.02% signal/mbar |
| Pressure transient (step change of 60 cm H2O) | 150% signal change |
| Long-term output drift | 5% signal loss (lifetime) |
| Expected working life | 5 years (in air) |

|