| Sign In | Join Free | My benadorassociates.com |
|
| Categories | 12V LiFePO4 Battery Pack |
|---|---|
| Brand Name: | TAC OEM ODM |
| Model Number: | 12V 150AH |
| Certification: | MSDS REACH ROHS |
| Place of Origin: | GUANGZHOU |
| MOQ: | 50 PCS |
| Price: | usd 285 |
| Payment Terms: | L/C, T/T, Western Union |
| Supply Ability: | 100 per week |
| Delivery Time: | 7-25 days after order confirm |
| Packaging Details: | 10pcs for one carton |
| Type: | LiFePO4 Battery Pack |
| voltage: | 12V |
| Voltage: | 12.8-13.2V |
| Size: | 483*165*235mm |
| Capacity: | 145A |
| Maximum discharge current: | 100A |
| Net: | 15.5kg |
| Company Info. |
| Guang Zhou Sunland New Energy Technology Co., Ltd. |
| Verified Supplier |
| View Contact Details |
| Product List |
Deep Cycle Long Cycle Rechargeable 12V 150AH LifePO4 Battery
Deep Cycle Long Cycle Rechargeable 12V 150AH LifePO4 Battery
Battery specifications:
| No. | Items | Specifications | Remark | |
1 | Capacity for assembled cell discharging by 0.2C | ≥145Ah | Standard discharging method | |
2 | Battery Voltage | 12.8-13.2V | Delivery voltage, Within 10 days from Factory | |
3 | Standard charge condition | Charge with 0.2C constant current and 14.6Vconstant voltage, charge to 14.6V continue charging till current decline to ≤0.01C | Charge voltage: 14.6V±0.02V Charge current:0.2C | |
4 | Maximum charge current | 100A | For continuous charging mod | |
5 | Maximum discharge current | 100A | For continuous discharge mod | |
6 | Standard discharging method | 0.2C constant current discharge to 8V, | ||
7 | Internal Impedance | Assemblage Impedance | Measure two sides of the drawing line after assembling. . | |
| 8 |
| 15.5Kg | ||

Safty performance:
| No. | Items | Test Method and Condition | Criteria |
| 1 | Thermal exposure test | Each fully charged cell, stabilized at room temperature, is placed in a circulating air-convection oven. The oven temperature is raised at a rate of 5 °C/min ± 2 °C/min to a temperature of 130 °C ± 2 °C. The cell remains at this temperature for 10 min before the test is discontinued. | No fire, No explosion |
| 2 | Low pressure | Each fully charged cell is placed in a vacuum chamber, in an ambient temperature of 20~25℃. Once the chamber has been sealed, its internal pressure is gradually reduced to a pressure equal to or less than 11.6 kPa (this simulates an altitude of 15240 m) held at that value for 6 h. | No leakage, No fire, No explosion |
| 3. | Short test | The fully charged battery is to be short-circuited by connecting the positive and negative terminals of the battery with resistance load not exceed 100mΩ. Tests are to be conducted at room temperature 20~25℃. | No fire, No explosion The Temperature of the Battery surface not exceeded than 150℃ |
| 4 | Over Discharg | (After standard charge. Cells are discharged at constant Current of 0.2C to 2.0V, and the positive and negative terminal is connected by a 30Ω wire for 24 hours. Cell Condition: Fresh, Fully charged cell.) | No fire, No explosion |
| 5 | Over charge test | After standard charge, continue to charge with a constant voltage 4.8V per a cell, holding 8h. | No leakage, No fire, No explosion |
| 6 | Soak Test | Put the batteries into clean water, be soaked for 24 hours. | No break, No fire |
|