| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Electric Current Transducers | 
|---|---|
| Brand Name: | Acrel | 
| Model Number: | BM200-DI/I-B11 | 
| Place of Origin: | China | 
| MOQ: | 1 pc | 
| Payment Terms: | T/T | 
| Supply Ability: | 1000pc/day | 
| Delivery Time: | 2-3 days | 
| Packaging Details: | cartoon | 
| Input: | DC 0~5V or DC 4-20mA | 
| Impedance: | 0.01Ω | 
| Max.input: | 1.2 times continuously;10 times for 1s transiently | 
| Output: | DC4-20mA or 0-20mA | 
| Protection: | Short circuit protection | 
| Response time: | ≤400ms | 
| Company Info. | 
| Jiangsu Acrel Electrical Manufacturing Co., LTD. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
Acrel new designed analog isolation barrier electrical in plc used
in petrochemical productions
Connected between intrinsically safe circuits and non-intrinsically
safe circuits. A device that limits the voltage or current supplied
to an intrinsically safe circuit within a safe range. Safety
barrier is a general term, divided into zener safety barrier and
isolation safety barrier, isolated safety barrier is referred to as
isolation barrier.
| Technical parameters | Index | |
| Input | Range | DC 0~5V or DC 4-20mA | 
| Impedance | 0.01Ω | |
| Max.input | 1.2 times continuously;10 times for 1s transiently | |
| Output | Range | DC4-20mA or 0-20mA | 
| Load | ≤500Ω | |
| Zero adjustment | 5% | |
| Span adjustment | 5% | |
| Protection | Short circuit protection | |
| Power supply | Range | 8.5-40V DC,normally 24VDC/2W | 
| Max.current | 24mA | |
| Other | Accuracy/linearity | Max.0.5%of full span | 
| Temperature effect | ≤200ppm/℃ | |
| Response time | ≤400ms | |
| Isolation voltage | 2kV between input and output | |
| Operating/storage temperature | -10℃~+55℃/-25~+70℃ | |




|   | 
 Acrel BR-AI 200-1000A Rogowski Coil Transducer Power Supply DC24V Conduct The Real-time Ac Measurement In The Power Grid
                                                                                    
                        
                        
                        
                                                            Acrel BR-AI 200-1000A Rogowski Coil Transducer Power Supply DC24V Conduct The Real-time Ac Measurement In The Power Grid
                                                    
                        
                     AC Multi Function Transducer BD-4E 3 Phase 4 Wire
                                                                                    
                        
                        
                        
                                                            AC Multi Function Transducer BD-4E 3 Phase 4 Wire
                                                    
                        
                     Analog Signal BD Electric Current Transducers Measure Leakage Current
                                                                                        
                                                        
                        
                        
                        
                                                            Analog Signal BD Electric Current Transducers Measure Leakage Current
                                                    
                        
                     Acrel BM100-DI/I-C12 DC 4-20/0-20 MA Input/output Current Sensor Analog Signal Isolator Transductor  1 Input 2 Output
                                                                                        
                                                        
                        
                        
                        
                                                            Acrel BM100-DI/I-C12 DC 4-20/0-20 MA Input/output Current Sensor Analog Signal Isolator Transductor  1 Input 2 Output
                                                    
                        
                     Acerl BD Series Power Transmitter Transmit Electrical Parameters Into Linear Tributary Analog Or Digital Signals Device
                                                                                    
                        
                        
                        
                                                            Acerl BD Series Power Transmitter Transmit Electrical Parameters Into Linear Tributary Analog Or Digital Signals Device
                                                    
                        
                     BA Series Din Rail Acrel Ac Current Transducer Straight Through 4-20ma 0-5v
                                                                                    
                        
                        
                        
                                                            BA Series Din Rail Acrel Ac Current Transducer Straight Through 4-20ma 0-5v
                                                    
                        
                     Acrel BD-3I3 Series Current Transmitter 3 Phase Current Isolate And Transmit 3 Analog Output Fix To Cubicle With Bolt
                                                                                    
                        
                        
                        
                                                            Acrel BD-3I3 Series Current Transmitter 3 Phase Current Isolate And Transmit 3 Analog Output Fix To Cubicle With Bolt
                                                    
                        
                     Acrel BA05-AI/I Ac Split Type Current Sensor DC Output Measuring Range 0~(0.5~10)A TS35mm Din Rail In The Power Grid
                                                                                        
                                                        
                        
                        
                        
                                                            Acrel BA05-AI/I Ac Split Type Current Sensor DC Output Measuring Range 0~(0.5~10)A TS35mm Din Rail In The Power Grid
                                                    
                        
                     BD-3I3 50HZ-60HZ 3 Phase Current Transducer AC Current Transmitter
                                                                                        
                                                        
                        
                        
                        
                                                            BD-3I3 50HZ-60HZ 3 Phase Current Transducer AC Current Transmitter
                                                    
                        
                     Acrel BM-TR/IS Series Signal Isolator Converted Into Standard Analog Signal Output PT100 Input Signal Isolated By 2000V
                                                                                        
                                                        
                        
                        
                        
                                                            Acrel BM-TR/IS Series Signal Isolator Converted Into Standard Analog Signal Output PT100 Input Signal Isolated By 2000V