Sign In | Join Free | My benadorassociates.com
benadorassociates.com
Products
Search by Category
Home > Other Security & Protection Products >

800V DC Surge Protector 2P Replace Type DIN 43880 40kA

Categories DC Surge Protector
Brand Name: FEEO
Model Number: dc spd
Certification: CE TUV
Place of Origin: CHINA
Payment Terms: L/C, D/A, D/P, T/T, Western Union, Western Union, MoneyGram
Delivery Time: 15work days
Code: FSP-D40
Pole: 2P/3P
In(8/20)us(KA): 20KA
Imax(8/20)us(KA): 40KA
Standard: IEC/EN61643
Type: II
Characteristic Curve: B,C,D
Protection Degree: IP20
Electrical life: More than 8000times
Mechanical life: More than 2000times
Capacity: 3 Modules, DIN 43880
Product Warranty: TWO YEARS
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

800V DC Surge Protector 2P Replace Type DIN 43880 40kA

ModelFSP-D40
UC (V DC)600/800V
Max System Discharge Current (8/20 μs) [Imax]40kA
Voltage Protection Level [UP]≤2.5kV
Integrated Fuse Breaking Capacity/Interrupting Rating40kA/600Vdc
TechnologyShort-Circuit Interruption (SCI) Overcurrent Protection
Operating Temperature Range [TU]-40°C to +80°C
Nominal Discharge Current (8/20 μs) [(DC+/DC-) --> PE] [n]20kA
Response Time [tA]<25ns
Operating State/Fault IndicationGreen (good)/Red (replace)
Conductor Ratings and Cross-Sectional AreaMin
MountingMax60/75°C 1.5mm2/14AWG Solid/Flexible
35mm DIN Rail per EN 6071560/75°C 35mm/2AWG Stranded/25mm2/4AWG Flexible
Enclosure MaterialUL 94V0 Thermoplastic
Degree of ProtectionIP20
Capacity3 Modules, DIN 43880
Standards InformationIEC 61643-31 Type 2, IEC 61643-1 Class II
Product WarrantyTwo Years**

1) Selection of voltage protection level (UP)

The value of UP should not exceed the rated value of the impulse withstand voltage of the protected equipment, and UP requires that the insulation of the SPD and the protected equipment should be well matched.

In the low-voltage power supply and distribution system, the equipment should have a certain ability to withstand surges, that is, the ability to withstand impulse overvoltage. When the impulse overvoltage withstand voltage of various equipment of 220/380V three-phase system cannot be obtained, it can be selected according to the given index of IEC 60664-1 and GB 50057-1994 (2000 edition).

2) Selection of nominal discharge current In (impact current capacity)

The peak current of the 8/20 μs current wave that flows through the SPD. It is used for class II classification test for SPD, and also used for pretreatment of class I and class II classification test for SPD.

In fact, In is the maximum peak value of the inrush current that the SPD can pass the specified number of times (generally 20 times) and the specified waveform (8/20 μs) without substantial damage.

3) Selection of the maximum discharge current Imax (limit impact current capacity)

The peak current flowing through SPD, 8/20 μs current wave, used for class II classification test. There are many similarities between Imax and In. They both use the peak current of 8/20 μs current wave to do Class II classification test on SPD. The difference is also obvious. Imax only does one impact test on SPD, and SPD does not undergo substantial damage after the test; while In can do 20 such tests, SPD cannot have substantial damage after the test. Therefore, Imax is the current limit value of the impact, so the maximum discharge current is also called the limit impact current capacity. Obviously, Imax>In.


Buy 800V DC Surge Protector 2P Replace Type DIN 43880 40kA at wholesale prices