| Sign In | Join Free | My benadorassociates.com |
|
| Categories | UVC Air Disinfection |
|---|---|
| Brand Name: | GYLED |
| Model Number: | GY1331UV40/GY1359UV60 |
| Certification: | GB28235;GB19258;Q/141000 GY008—2021 |
| Place of Origin: | CHINA |
| MOQ: | 10PCS |
| Price: | Negotiation |
| Payment Terms: | T/T, L/C, Western Union |
| Supply Ability: | 200000PCS/YEAR |
| Delivery Time: | 7-10DAYS |
| Packaging Details: | 4PCS/6PCS IN 1CARTON |
| Rated Power: | 40W/60W |
| UV-C Light Type: | Philips TUV PL-L UV-C Light |
| Peak Wavelength: | 253.7nm |
| Light Source Life: | 10000h |
| Disinfection Type: | Common bacteria, viruses and other microorganisms |
| Recommended Using Area Dimension: | 10-20m² |
| Recommended Filter Replacement Frequency: | 3-6 months |
| IP Rating: | IP20 |
Main Performance and Parameters:
| Parameters Items | GY1331UV40 | GY1359UV60 |
| Rated Power | 40W | 60W |
| Input Voltage | AC220-240V 50/60 Hz | |
| Power Factor | ≥0.9 | |
| UV-C Light Type | Philips TUV PL-L UV-C Light | |
| Peak Wavelength | 253.7 nm | |
| Light Source Life | 10000H | |
| Disinfection Type | Common bacteria, viruses, and other microorganisms | |
Recommended Using Area Dimension | 10-15m² | 15-20m² |
| Recommended Filter Replacement Frequency | 3-6 months | |
| Working Duration Limit | Available for long-term operation | |
| IP Rating | IP20 | |
| Electric Safety Class | CLASS I | |
| Surface Treatment | Anti-corrosive powder coating | |
| Dimension | 318*133*121mm | 638*133*121mm |
| Net Weight | 2.1Kg | 3.8Kg |
| Executive National Standard | GB28235;GB19258;Q/141000 GY008—2021 | |
Troubleshooting:
| SN | Fault Description | Cause of Fault | Troubleshooting Method |
| 1 | The power is on, the indicator light is off, and the fan is working normally | UV-C light is damaged | Replace with a new UV-C light |
| 2 | The power is on, the indicator light is off, and the fan does not work | The socket has no electricity, or the product switch is faulty | Check whether the socket is electrified. If the socket has electricity, check whether the input circuit such as the product switch is normal |
| 3 | The fan noise has increased significantly | Too much dust on the filter | Replace with a new filter |
Commercial UV HEPA wall mount plasma ion air purifier and air sterilizer remove order industrial uv light disinfection
sterilization lamp can help you against:
Mold Spores
Size: 10 – 30 μm
• Survives under harsh environmental conditions or dry conditions
Skin Flakes
5-10 microns
• Mattress
• Pillow
• Long-fibred carpets
• Upholstered furniture
Pollen
Size: 1 – 100 μm
• Outdoor/ Indoor plants
• From grasses, trees, flowers, and weeds
LARGE COVERAGE: Cleans spaces up to 1100 sq.ft in 50 minutes, 550 sq.ft in 25 minutes, 110 sq ft in 10 minutes. No matter in a whole house, offices, living rooms, apartments, restaurants, or other businesses, it performs to perfection.
EASY OPERATION: Touch control panel with 1,2,4,8hour timer, 3 fan speeds, sleep mode, filter replacement indicator, and child lock, great ideal for both kids and pets.
ULTRA-QUIET: Min noise level of 25dB and max of 40dB.Choose from 3 fan speeds, with the lowest setting operating virtually silent.






|