| Brand Name: | Sanwu Cable |
| Model Number: | ACSR-002 |
| Certification: | ISO CCC, |
| Place of Origin: | Henan |
| MOQ: | 1000M |
| Price: | Negotiable |
| Payment Terms: | L/C, T/T, Western Union, MoneyGram |
| Supply Ability: | 200 tons per day |
| Delivery Time: | 1-15days |
| Packaging Details: | New Wooden drum, reel, circle, or according to customers request. |
| Product Name: | Aluminum Conductor Steel Reinforced |
| Original: | Henan, China |
| Material: | Aluminum steel |
| Manufacture: | Yes |
| Voltage rated: | 0.6/1kv |
| Application: | Overhead Transmission line |
| Company Info. |
| Luoyang Sanwu Cable Co., Ltd., |
| Verified Supplier |
| View Contact Details |
| Product List |
Low Voltage Aluminum Conductor Steel Reinforced Overhead
Transmission
Application of Aluminum Conductor Steel Reinforced
Aluminum Conductor Steel Reinforced have been widely used in power
transmission lines with various voltage levels,because they have
such good characteristics as simple structure,convenient
installation and maintenance,low cost large transmission capacity.
And they are also suitable for laying across rivers valleys and the
places where special geographical features exist.
Installation of Aluminum Conductor Steel Reinforced
It is recommended that the installation instructions indicated by
the Local Electric Code, or any equivalent, be followed, so that
the safeguarding of persons and the integrity of the product will
not be affected by deficiencies in the installation.
| Code | Size (AWG/MCM) | Number of Strands(mm) | Weight(kg/km) | Rated Strength(kg) |
| Rose | 4 | 7*1.96 | 58.3 | 399 |
| Iris | 2 | 7*2.47 | 92.7 | 611 |
| Pansy | 1 | 7*2.78 | 117 | 740 |
| 1/0 | 1/0 | 7*3.12 | 147.5 | 897 |
| Aster | 2/0 | 7*3.5 | 186 | 1375 |
Service Performance:
(1). The permissible long-time operating temperature for aerial
conductor is 70℃.
(2). Under the circumstance that rare climate is occurring and ice
coverage rate low in heavy ice area, the biggest stress of cable at
the lowest point of the sag should not exceed 60% of the short-time
destructive power.
(3). When connecting conductors, the conductor beside the
connecting tube cant be prominent. Otherwise, the force on the
operating conductors will be unbalanced. After connectors are
install, the connecting tube should be painted by moisture-proof
varnish in order to protect it from corrosion.
(4). Under installation, the arc downing stress of all the
conductors should be the same. With in the permissible distance of
crossing buildings or dropping to the ground, the stress can be
10-15% higher than regular stress.

|