| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Patient Monitor Module |
|---|---|
| Brand Name: | GE |
| Model Number: | E-PSMPW |
| MOQ: | 1pcs |
| Payment Terms: | T/T(wire transfer), Western Union, Paypal |
| Delivery Time: | 3-5 working days |
| Packaging Details: | Carton |
| Product Name: | GE Datex Ohmeda E-PSMPW Carescape Patient Side Module |
| Brand: | GE |
| Part No: | E-PSMPW |
| Module size (W x D x H): | 55 x 135 (175 w/ tab) x 145 mm (2.2 x 5.3 (6.9 w/ tab) x 5.7 in) |
| Module weight: | 0.6 kg /1.4 lb |
| Operation temperature: | 5 to 40°C / 41 to 104°F |
| Parameter: | NIBP,ECG,Pulse oximetry,Temperature,Invasive blood pressure,Respiration, |
| MOQ: | One piece |
| Warranty: | 90 days |
| Condition: | Work in good |
| Company Info. |
| China World Technology Medical Equipment Service Group |
| Verified Supplier |
| View Contact Details |
| Product List |
GE Datex Ohmeda E-PSMPW Carescape Patient Side Module
Specification
| Module size (W x D x H) | 55 x 135 (175 w/ tab) x 145 mm (2.2 x 5.3 (6.9 w/ tab) x 5.7 in) |
| Module weight | 0.6 kg /1.4 lb |
| Operation temperature | 5 to 40°C / 41 to 104°F |
NIBP
NOTE: Non-invasive blood pressure measurement is intended for patients weighing over 5 kg
| Measurement range | |
| adult | 25 to 260 mmHg |
| child | 25 to 190 mmHg |
| infant | 15 to 140 mmHg |
| Pulse rate range accepted | 30 to 250 bpm |
| Typical measuring time | |
| adult | < 30 s |
| infant | < 25 s |
| Inflation limit | |
| adult | 280 ±10 mmHg |
| child | 200 ±10 mmHg |
| infant | 150 ±5 mmHg |
| Venous stasis | |
| adult | 80 ±5 mmHg / 2 min |
| child | 60 ±5 mmHg / 2 min |
| infant | 40 ±5 mmHg / 1 min. |
| Lead type | 3-Lead (I, II, III) 5-Lead (I, II, III, aVR, aVL, aVF, V) |
| Sweep speeds | 12.5, 25, 50 mm/sec. |
| Defibrillation protection | 5000 V, 360 J |
| Recovery time | 5 s |
| Input impedance | >2.5 MΩ (10 Hz) |
| Allowable offset | ±1VDC |
| Gain range | 0.2 to 5.0 cm/mV |
| Measurement range | 0 to 100% |
| Calibration range | 70 to 100% |
| Pulse rate from Pleth | |
| Measurement range | 30 to 250 bpm |
| Accuracy | ±5 bpm or ±5%, whichever is greater |
| Resolution | 1 bpm |
| Display averaging | 5-20 s |
| Measurement range | 10 to 45 °C (50 to 113 °F) |
| Measurement accuracy | ±0.1 °C |
| Display resolution | 0.1 °C at 25-45 °C with reusable probes |
| Temperature test | automatic (every 10 min.) |
| Probe type | compatible with YSI 400 series |
| Measurement range | -40 to 320 mmHg |
| Measurement accuracy | ±5% or ±2 mmHg, whichever is greater |
| Zero adjustment range | ±150 mmHg |
| Zero time | less than 15 s |
| Transducer sensitivity | 5 µV/V/mmHg |
| Measurement range | 4 to 120 breath/min |
| Accuracy | ±5 breath/min or ±5%, whichever is greater |
| Resolution | 1 breath/min |
| Gain range | 0.1 to 5cm/ohm |
Patient Side Module E-PSMPW

(1) Module keys
Module keys
The E-PSM(P)W modules have the following direct function keys:
For starting or stopping the NIBP automatic cycling.
For starting or stopping the NIBP manual cycling.
For zeroing pressure channel P1 NOTE: with E-PSMPW only.
For zeroing pressure channel P2 NOTE: with E-PSMPW only.

Thank you for your attention .If you're interested in GE Datex Ohmeda E-PSMPW Carescape Patient Side Module,feel free to contact us .Thank you .
|