| Sign In | Join Free | My benadorassociates.com | 
 | 
| Categories | Medium Voltage Load Bank | 
|---|---|
| Brand Name: | Fullde | 
| Model Number: | LB-2000KVA-6.9KV | 
| Certification: | CE, ISO9001 | 
| Place of Origin: | Dongguan,China | 
| MOQ: | one set | 
| Price: | Negotiable | 
| Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram | 
| Supply Ability: | 50 sets per month | 
| Delivery Time: | 25 working days | 
| Packaging Details: | Packaged by Wooden Case with Soft Protective Material | 
| Wire Connection: | Load bank input——Copper bar; Control power input——Connector-bar | 
| Max Protection Grade: | IP56 | 
| Way of Working: | Continuous Working | 
| Cooling: | Forced air cooling, horizontal inlet air and upwards exhaust cooling | 
| Transportation: | Hoisting | 
| Color: | RAL7032 | 
6.9kV 2000kVA Medium Voltage Load Bank for Medium Voltage Generator Testing
Application of Load Bank:
1. Large generator system testing in ocean engineering, drilling
facilities,ship construction etc field;
2. Factory testing for generator, static voltage characteristic
test, speed characteristic test;
3. Marine generator overload protection test,parallel operation
test,reverse power and reverse current protection test;
4. Assist shipyard in mooring test,sea trial test;
5. Assist with the acceptance of the vessel generator test;
6. Eliminate the carbon deposition of generator;
7. As the generator loading system;
8. Periodic running test for standby generator;
9. UPS inspection and maintenance;
10. Ship battery charging/discharging system testing;
11. The acceptance of new system and testing of servicing
equipment.
| Specification | |
| Rating voltage/frequency | AC6.9KV/400Hz | 
| Max Load Power | Apparent Power:2000KVA | 
| Load Resolution | step:200KVA | 
| Power Factor | 0.8 | 
| Load Tolerance | ±5% | 
| Fan Control Power | 110V/220V,50Hz/60Hz | 
| Wire Connection | Load bank input——Copper bar | 
| Control power input——Connector-bar | |
| Max Protection Grade | IP56 | 
| Way of Working | Continuous Working | 
| Cooling | Forced air cooling, horizontal inlet air and upwards exhaust cooling | 
| Transportation | Hoisting | 
| Color | RAL7032 | 
| Dimensions | 6058*2438*2591 | 
| Weight | 5000KG | 
| Accessories | Switch: ABB, Siemens and Schneider, PLC: Panasonic and Siemens; | 
| Operating Environment Parameter | |
| Ambient Temperature | -10℃~+50℃ | 
| Relative Humidity | ≤95% | 
Fullde electric has been selected in the list of key enterprise
Feb. 2017, the government released <the list of companies that will implement the key enterprise’s benefit redouble experiment >. Fullde stand out of millions of companies, and was selected in the list.
Fullde appreciate the governments’ trust and all Fullde people’s hard work to become one of the key enterprises. Look forward, in 2017, all Fullde people will roll up their sleeves, do our best to become the global acknowledged electric system service provider, fighting for the rise of Chinese equipment industry manufacture, do our bit for the Chinese dream!

|   | 
 Automatic Permanent Load Bank / Capacitive Load Bank With High Performance
                                                                                    
                        
                        
                        
                                                            Automatic Permanent Load Bank / Capacitive Load Bank With High Performance
                                                    
                        
                     1kw - 1500kw Dummy Medium Voltage Load Bank With Sound - Light Alarm System
                                                                                    
                        
                        
                        
                                                            1kw - 1500kw Dummy Medium Voltage Load Bank With Sound - Light Alarm System
                                                    
                        
                     Step Control Medium Voltage Load Bank With Stainless Steel Sheathed Elements
                                                                                    
                        
                        
                        
                                                            Step Control Medium Voltage Load Bank With Stainless Steel Sheathed Elements
                                                    
                        
                     Adjustable Generator Testing Load Bank With Control Pattern Interlock Function
                                                                                    
                        
                        
                        
                                                            Adjustable Generator Testing Load Bank With Control Pattern Interlock Function
                                                    
                        
                     3000KW 10.5KV Resistance UPS Load Bank Test , Diesel Generator Load Bank
                                                                                    
                        
                        
                        
                                                            3000KW 10.5KV Resistance UPS Load Bank Test , Diesel Generator Load Bank 
                                                    
                        
                     Intelligent Medium Voltage Load Bank With Energizing / De - Energizing Buttons
                                                                                    
                        
                        
                        
                                                            Intelligent Medium Voltage Load Bank With Energizing / De - Energizing Buttons
                                                    
                        
                     Hoisting Variable Resistive Load Bank TO Prevent The Generator Carbon Deposition
                                                                                    
                        
                        
                        
                                                            Hoisting Variable Resistive Load Bank TO Prevent The Generator Carbon Deposition
                                                    
                        
                     Indoor 50KVA AC Medium Voltage Load Bank With Software Programmable Control
                                                                                    
                        
                        
                        
                                                            Indoor 50KVA AC Medium Voltage Load Bank With Software Programmable Control
                                                    
                        
                     Indoor 50KVA AC Medium Voltage Load Bank With Software Programmable Control
                                                                                    
                        
                        
                        
                                                            Indoor 50KVA AC Medium Voltage Load Bank With Software Programmable Control
                                                    
                        
                     3.3kV  Medium Voltage Load Bank , Digital Metering Load Bank Testing Equipment
                                                                                    
                        
                        
                        
                                                            3.3kV  Medium Voltage Load Bank , Digital Metering Load Bank Testing Equipment