Sign In | Join Free | My benadorassociates.com
benadorassociates.com
Products
Search by Category
Home > Apparel & Textile Machinery Parts >

Bladed Disposable Laparoscopic Trocars For Laparoscopic Surgery

Categories Surgical Linear Stapler
Brand Name: New Life
Model Number: 5,10,12,15
Certification: ISO, CE
Place of Origin: China
MOQ: 100pcs
Payment Terms: T/T, Western Union
Supply Ability: 5000pcs/month
Delivery Time: 10-30days
Packaging Details: 1pcs/box, 10pcs/carton
Properties: Microsurgery Device
Application: Thoracic,Bariatric,Colorectal,Gynecologic,General surgery
Diameter: 5,10,12,15mm
Cannula Length: 65mm, 100mm, 150mm
Function: Bladed
Sterilization: EO Sterilization
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Bladed Disposable Laparoscopic Trocars For Laparoscopic Surgery

Disposable Bladed Laparoscopic Trocars For Laparoscopic Surgery


Disposable Bladed Laparoscopic Trocar

Introduction:

For passive medical device, describe working principle, function mechanism (if applicable), structural composition (including accessories used cooperatively), main raw materials, and contents differing from characteristics, etc. of other similar products; provide graphic illustration when necessary.

Working principle

During use, the Disposable laparoscopic puncture establishes pneumoperitoneum in advance, and makes a proper incision at a proper position on the abdomen. Fix the Trocars on the abdomen raised by pneumoperitoneum at a proper angle by hand. Insert the Trocars into the skin incision, and pull out the Trocars cone to form a work channel for observation and operation with the laparoscope/device.

Structural composition

Disposable laparoscopic puncture design and development of the company (hereinafter referred to as the Trocars device) is mainly composed of a Trocars Cannula and Trocars core, Trocars cannula mainly comprises a sealing cover, injection valve and choke valve, sleeve etc.

Main raw materials

Table 1 Material Requirements of Main Parts

Part NameMaterial DesignationStandard No.
Trocars Core,Trocars CannulaPCEN ISO 7391-1:2006
Trocars core fixed seatABSENISO 19062-1:2015
Trocarse core tube12Cr18Ni9EN ISO 7153-1:2016

Contradiction

Disposable Trocar is not intended to be used when endoscopic techniques generally are the contraindications.


Basic size as well as model and specification comparison table

The basic size of the Trocars shall conform to the provisions in Table 1.

Table 1 Basic Size of Trocars in mm

Trocars SpecificationsTrocars core outer diameter(D)Cannula length(L)Trocars cannula inner diameter(d)
Basic sizeLimit deviation
PC5S5.8±0.877±26

+0.3

0

PC5M102±2
PC5L152±2
PC10S10.8±0.877±211
PC10M102±2
PC10L152±2
PC12S12.8±0.877±213
PC12M102±2
PC12L152±2
PC15S15.8±0.877±216
PC15M102±2
PC15L152±2


Cautions

1. Check the package before using. Don't use if the package is damaged.

2. This product is for single patient use only. Do not reuse.

3. Make sure the product is within the expiry date. It is strictly prohibited to use the product beyondthe expiration date.

4. Endoscopic surgery should be performed by surgeons who are familiar with endoscopic techniques.Reference to medical literature relative to technique, complication and other risks is necessary.

5. Failure to establish and maintain appropriate pneumoperitoneum in laparoscopic surgery may reduce the working space, it may increase the risk of injury to internal structure.

6. Verifying the compatibility with trocar before using the instruments and accessories from different manufacturers.

7. Always inspect the operative site for hemostasis when removing trocar from the abdominal or chest cavity. Bleeding can be controlled by electrocautery or manual sutures.

8. Closure of the fascia is up to the surgeons' discretion. Fascia layer may be sutured to reduce the risk of incisional hernia


FAQ

1. Q:Are you a factory or trading company?
A: We are a factory, we have rich experience for manufacturing Medical Device more than 10 years.
2. Q:Where is your factory located? How can i visit there?
A: Our factory is located in Jiaxing city, Zhejiang Province, China.
It is about more than 1 hours from Shanghai.

2. 3.Q:Can you make samples?
A: Yes, we can make samples for you.
4. Q:How does your factory do as quality control?
A: Quality is the lift of our factory. We have inspector in different post, and there are three inspectors before packing to get best quality products.
5. Q: How is your post market service ?
A: If any damaged rings in the course of carriage, with the checking it's our mistake, we will take full responsibility to compensate the customers.

6. Q:Can you do OEM for us?
A: Certainly. We also can build the moulding for our new customer.

7. Q:Does the price include freight?
A: No, please choose the express service provider or negotiate with us.

Buy Bladed Disposable Laparoscopic Trocars For Laparoscopic Surgery at wholesale prices
Send your message to this supplier
 
*From:
*To: Orient New Life Medical Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0