| Categories | Stationary Meter Test System |
|---|---|
| Certification: | ISO, CE |
| Supply Ability: | 100/Year |
| Payment Terms: | L/C,T/T,D/P |
| Brand Name: | GENY |
| Model Number: | YC1893D |
| Place of Origin: | CHNA |
| Model NO.: | YC1891D |
| Test current output: | 1mA – 100A or customized,Max.200A |
| Reference Standard Meter: | SZ01A-K3 |
| Setting accuracy: | 0.1° |
| Accuracy: | 0.05 |
| Test voltage output: | 24V – 288V or customized |
| Ambient temperature: | -10°C -- +40°C |
| Relative humidity: | 35% -- 85% |
| Company Info. |
| Guangzhou GENY Electric Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |
YC1891D-6 | YC1891D-12 | YC1891D-24 | YC1891D-48 | |
Number of meter positions | 6 | 12 | 24 | 48 |
Accuracy | 0.05 | |||
Power Source | YCS-101-250 | YCS-101-600 | YCS-101-1200 | YCS-101-2500 |
Standard Meter | SZ01A-K3 | |||
MSVT | HJ200GL-6 | HJ200GL-12 | HJ200GL-24 | HJ200GL-48 |
QCD | D5 series | |||
Scanning Head | YCG-2 series | |||
Voltage | ||||
Test voltage output | 24V – 288V or customized | |||
Power of the voltage output | 100VA | 250VA | 500VA | 1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Current | ||||
Test current output | 1mA – 100A or customized,Max.200A | 1mA – 100A | ||
Power of the current output | 150VA | 350VA | 750VA | 1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | Better than 0.01% | |||
Distortion factor | Better than 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Phase angle | ||||
Range | 0 -- 360° | |||
Resolution | 0.01° | |||
Setting accuracy | 0.1° | |||
Frequency | ||||
Range | 45Hz – 65Hz | |||
Resolution | 0.01Hz | |||
Error display | ||||
Type of error display | Red LED | |||
Resolution of the error displays | 8 digits | |||
Voltage Supply | 220V±10% or customized 50/60Hz±2Hz | 3x220/380V±10% or customized 50/60Hz±2Hz | ||
Ambient temperature | -10°C -- +40°C | |||
Relative humidity | 35% -- 85% | |||



*If you want to know more please check our official website:http://www.genymetertestequipment.com/
|