Sign In | Join Free | My benadorassociates.com |
|
Categories | Refrigerated Centrifuge |
---|---|
Brand Name: | MKE |
Model Number: | VL-200R |
Certification: | CE, ISO, IUV |
Place of Origin: | China |
Product Type: | Multi-function High Speed Refrigerated Centrifuge |
Maximum Speed: | 21000 rpm |
Max Capacity: | 4x750ml |
Angle Rotor: | 6x100ml |
Rotor Material: | Titanium alloy and aluminum alloy |
Timer Range: | 1min to 99min |
Applications: | Scientific Research,Medical laboratories |
Parameters: | speed,timer,RCF,temperature,rotors |
Matched Rotors: | Fixed angle rotors,swing out rotors |
Company Info. |
Hunan Michael Laboratory Instrument Co.,Ltd. |
Verified Supplier |
View Contact Details |
Product List |
Technical Specifications:
Speed range(rpm) | 0-20000rpm adjustable | Time range | 1-99minutes 59s adjustable |
Max Capacity(ml) | 4*750ml | Speed accuracy | ±10r/min |
RCF range (xg) | 0-28174xg adjustable | ACC/DEC | 1-10 rates |
Temperature control range | -20℃~+40℃ | Temperature control accuracy | ±1℃ |
Noise(dBA) | ≦58dB(A) | Net weight(without rotor) | 110KGS |
Power supply | AC220V,50HZ,10A, 1300W | Dimension(mm) | 680x580x420mm(LxWxH) |
Matched Rotors(Customized rotors are available)
No. | Item | Max. capacity | Max.speed | Max.RCF | Note |
NO.1 | Angle rotor | 12x1.5/2.2ml | 20000r/min | 28174xg | PP/PC tube |
Adapter | 12x0.5ml | PP/PC tube | |||
Adapter | 12x0.2ml | PP/PC tube | |||
NO.2 | Angle rotor | 12x5ml | 19000r/min | 25830xg | PP/PC tube |
Adapter | 12x1.5ml | PP/PC tube | |||
NO.3 | Angle rotor | 24x1.5/2.2ml | 16000r/min | 24041xg | PP/PC tube |
Adapter | 24x0.5ml | PP/PC tube | |||
Adapter | 24x0.2ml | PP/PC tube | |||
NO.4 | Angle rotor | 10x15ml | 15000r/min | 26161xg | PP/PC tube |
Adapter | 10x10ml | PP/PC tube | |||
Adapter | 10x5ml | PP/PC tube | |||
Adapter | 10x1.5ml | PP/PC tube | |||
N0.5 | Angle rotor | 48×1.5/2.2ml | 15000r/min | 23394xg | PP/PC tube |
Adapter | 48x0.5ml | PP/PC tube | |||
Adapter | 48x0.2ml | PP/PC tube | |||
NO.6 | Angle rotor | 12×10ml | 15000r/min | 21130xg | PP/PC tube |
Adapter | 12×5ml | PP/PC tube | |||
Adapter | 12x1.5ml | PP/PC tube | |||
NO.7 | Angle rotor | 6×50ml | 14000r/min | 21255xg | PP/PC tube |
Adapter | 6×15ml | PP/PC tube | |||
Adapter | 6×10ml | PP/PC tube | |||
Adapter | 6×1.5ml | PP/PC tube | |||
NO.8 | Angle rotor | 6×100ml | 11000r/min | 14610xg | PP/PC tube |
Adapter | 6×50ml | PP/PC tube | |||
Adapter | 6×15ml | PP/PC tube | |||
Adapter | 6×10ml | PP/PC tube | |||
Adapter | 6×5ml | PP/PC tube | |||
Adapter | 6×1.5ml | PP/PC tube | |||
NO.9 | Angle rotor | 8×50ml | 12000r/min | 17226xg | PP/PC tube |
Adapter | 8×15ml | PP/PC tube | |||
Adapter | 8×10ml | PP/PC tube | |||
Adapter | 8×1.5ml | PP/PC tube | |||
NO.10 | Swing bucket | 4×250ml | 4000r/min | 3049xg | Round cup |
Adapter | 4×9x5/2ml | PP/PC tube | |||
Adapter | 4×5x15/10ml | PP/PC tube | |||
Adapter | 4×50ml | PP/PC tube | |||
Adapter | 4×100ml | PP/PC tube | |||
Adapter | 4×9x1.5ml | PP/PC tube | |||
NO.11 | Swing bucket | 4×400ml | 4000r/min | 3049xg | Square cup |
Adapter | 4×16x5/2ml | PP/PC tube | |||
Adapter | 4×9x15/10ml | PP/PC tube | |||
Adapter | 4×4x50ml | PP/PC tube | |||
Adapter | 4×100ml | PP/PC tube | |||
Adapter | 4×15x1.5ml | PP/PC tube | |||
NO.12 | Swing bucket | 4×500ml | 4000r/min | 3354xg | Round cup |
Adapter | 4×17x5/2ml | PP/PC tube | |||
Adapter | 4×8x15/10ml | PP/PC tube | |||
Adapter | 4×3x50ml | PP/PC tube | |||
Adapter | 4×100ml | PP/PC tube | |||
NO.13 | Swing bucket | 4×600ml | 4000r/min | 3354xg | Square cup |
Adapter | 4×25x5/2ml | PP/PC tube | |||
Adapter | 4×12x15/10ml | PP/PC tube | |||
Adapter | 4×5x50ml | PP/PC tube | |||
Adapter | 4×4x100ml | PP/PC tube | |||
NO.14 | Swing bucket | 4×750ml | 4000r/min | 3443xg | Round cup |
Adapter | 4×26x5/2ml | PP/PC tube | |||
Adapter | 4×13x15/10ml | PP/PC tube | |||
Adapter | 4×5x50ml | PP/PC tube | |||
Adapter | 4×3x100ml | PP/PC tube | |||
NO.15 | Microplate rotor | 2×2×96 hole | 4200r/min | 2860xg | Square cup |
Adapter | 2×32×1.5ml | PP/PC tube |
The combination of high speed and refrigeration capabilities ensures precise temperature control during centrifugation, preserving sample integrity and allowing for sensitive experiments and analyses.
They are essential for separating substances of different densities
in biological and chemical samples, such as DNA, proteins, and
cells. These centrifuges are particularly valuable in fields like
molecular biology, biochemistry, and clinical diagnostics, enabling
researchers to isolate and purify target components efficiently.
WHY CHOOSE US
Our Factory Introduction
We have a standardized production workshop operated by a dedicated
team that ensures quality in every laboratory centrifuge and lab
equipment we produce. Our R&D division includes design
engineers, technology specialists, qualified experts, and process
control managers. Following a strict quality control system, our
specialists oversee the entire production process, from design and
R&D to testing, production, quality inspection, and packaging.
Specialize in centrifuges.
With decades of experience, we've exported to 80+ countries.
Proven Reputation: SGS and Intertek inspected, underlining our reliablity.
Manufacturing Capabilities: 6 floors, 3000 sqm each, dedicated to
manufacturing and quality control.
MKE Exhibition
Packaging & Delivery
MKE centrifuges are securely packaged in wooden cases or carton boxes, selected according to the weight and size of the goods. This ensures they are delivered in excellent condition to customers worldwide.
After-Sale WARRANTY
FAQ
![]() |