ASTM B111 UNS C70600 Copper Nickel Tube Heat Exchanger Replacement Tube

Categories Copper Alloy Tube
Brand Name: YUHONG
Model Number: ASTM B111 UNS C70600 Seamless Copper Nickel Tube
Certification: ABS, GL, DNV, NK, PED, AD2000, GOST9941-81, CCS, ISO 9001-2008
Place of Origin: CHINA
MOQ: 500kgs
Payment Terms: L/C, T/T
Delivery Time: 7days
Packaging Details: Ply-wooden Case /Iron Case/ Bundle with plastic Cap
Product Name: Copper Nickel Tube
Standard: ASTM B111, ASME SB111
Material: UNS C70600
O.D: 6.35mm to 114.3mm
Thickness: BWG 10,12,14,16,18,20,22
Length: Single Random Length, Double Random Length, Customize Size
End: Plain End, Beveled End
Type: Seamless
Application: Condenser, Evaporator and Heat Exchanger tubes; Distiller tubing; Salt Water piping.
High Light: ASTM B111 UNS C70600 Copper Alloy Seamless Tube, Cu90Ni10 Seamless Heat Exchanger Tube
Company Info.
Yuhong Group Co.,Ltd
Verified Supplier
View Contact Details
Product List
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

ASTM B111 UNS C70600 Copper Nickel Tube Heat Exchanger Replacement Tube

Copper Nickel Tube ASTM B111 UNS C70600 Annealed Seamless Heat Exchanger Tube


Replacing the tubes in a heat exchanger requires careful planning and consideration of multiple factors, from material selection and design specifications to maintenance and regulatory compliance. A well-thought-out approach ensures that the replacement will enhance the performance and longevity of the heat exchanger. Copper nickel C70600 offers superior resistance to corrosion, especially in seawater and other aggressive environments. This is crucial for maintaining the integrity and performance of the heat exchanger over time.


When planning to replace the tubes of a heat exchanger, several important considerations should be taken into account to ensure a successful project. Here’s a comprehensive overview:

1. Material Selection

  • Compatibility: Ensure the new tubes match the existing materials or are compatible with the fluids used. Factors like corrosion resistance, temperature, and pressure ratings are essential.

  • Corrosion Resistance: Consider the environment the heat exchanger operates in (e.g., seawater, chemicals) and select materials that will withstand those conditions (e.g., C70600 for marine applications).

2. Design Specifications

  • Tube Diameter and Length: Verify the dimensions of the replacement tubes to ensure they fit properly. Changes in size can affect flow rates and thermal performance.

  • Number of Tubes: Ensure the number of replacement tubes matches the design requirements of the heat exchanger to maintain efficiency.

3. Heat Transfer Efficiency

  • Surface Area: Consider the surface area of the new tubes, as larger surface areas typically enhance heat transfer efficiency.

  • Design Factors: Evaluate how changes in material or design could influence overall heat exchanger performance.

4. Pressure and Temperature Ratings

  • Operating Conditions: Verify that the new tubes can handle the specified operating conditions of the heat exchanger, including maximum and minimum pressures and temperatures.

5. Installation Process

  • Downtime and Logistics: Plan for the downtime required to replace the tubes and coordinate the logistics for obtaining new materials.

  • Installation Techniques: Choose appropriate installation methods (such as welding, expansion, or mechanical fitting) that suit the materials and design.

6. Maintenance and Inspection

  • Ease of Maintenance: Consider how the new tubes will affect maintenance schedules and processes. Tubes that are easier to clean and inspect can improve long-term performance.

  • Reliability: Assess the expected life span of the new tubes and any specific maintenance needs.



Equivalent Material Grades

Material DesignationCorresponding Material Symbol
ASTM B111BS2871JIS H3300DIN1785GB/T 8890
Copper NickelC70600CN102C7060CuNi10Fe1MnBFe10-1-1
C71500CN107C7150CuNi30Mn1FeBFe30-1-1
C71640CN108C7164CuNi30Fe2Mn2BFe30-2-2
C70400BFe5-1.5-0.5
B7
Aluminium BrassC68700CZ110C6870CuZn20AL2HAL77-2
Admiralty BrassC44300CZ111C4430CuZn28Sn1HSn70-1
Boric BrassHsn70-1B
Hsn70-1 AB
Arsenical BrassCZ126H68A
Brass TubeC28000/C27200CZ108C2800/C2700CuZn36/CuZn37H65/H63

Chemical Composition & Mechanical Properties

Steel GradeCuSnAlAsNiFeMnPbZn
C70400Remain---4.8-6.21.3-1.70.3-0.80.05 max1.0 max
C70600Remain---9.0-11.01.0-1.81.0 max0.05 max1.0 max
C71500Remain---29.0-33.00.4-1.01.0 max0.05 max1.0 max
C71640Remain---29.0-32.01.7-2.31.5-2.50.05 max1.0 max

Application

  • Chillers
  • Heat Condensers & Exchangers
  • Power Plants
  • Refineries
  • Desalination Plants
  • Ship Building & Ship Repairs
  • Defence
  • High Capacity Power Plants
  • Distiller Tubes
  • Evaporators & Ferrules

Buy ASTM B111 UNS C70600 Copper Nickel Tube Heat Exchanger Replacement Tube at wholesale prices