Sign In | Join Free | My benadorassociates.com
benadorassociates.com
Products
Search by Category
Home > Financial Services >

600MHz SFTP CAT7 Cable 23AWG CPR Dca-S2 D2 A1 Gray PVC High Speed Network Cable

Categories SFTP CAT7 Cable
Brand Name: ITI-LINK
Model Number: ITI-CT7SF-007
Place of Origin: SHENZHEN
Certification: UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
MOQ: 1000pcs
Packaging Details: Color Box+Packing Box 36*36*21cm
Delivery Time: 15-45 Days
Payment Terms: T/T
Supply Ability: 2000pcs/day
Cable Type: CAT7
Length: 1000Ft
Shielding Type: SFTP
Frequency: 600MHz
Conductor Material: Copper
Jacket Material: PVC
Jacket Color: Gray
Conductor Size: 23AWG
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

600MHz SFTP CAT7 Cable 23AWG CPR Dca-S2 D2 A1 Gray PVC High Speed Network Cable

CAT7 SFTP 23AWG 600MHz CPR Dca-s2,d2,a1 Gray PVC High Speed Network Cable

Product Description:

1.This CAT7 LAN Cable, which is a CAT7 SFTP 23AWG 600MHz CPR Dca-s2,d2,a1 Gray PVC High Speed Network Cable, is designed to support speeds of up to 10Gbps over a distance of up to 100 meters. This makes it an ideal choice for both residential and commercial applications where high-speed data transfer is crucial. The cable is also backward compatible with Cat6 and Cat5e cables, so it can be used with older networking equipment.


2.One of the key features of this Cat 7 Lan Cable is its superior shielding. The cable features an SFTP (Shielded Foiled Twisted Pair) design with a 23AWG conductor that provides excellent protection against electromagnetic interference (EMI) and radio frequency interference (RFI). It complies with the CPR (Construction Products Regulation) standard and has specific Dca-s2,d2,a1 characteristics, which enhance its performance and safety in various networking scenarios. This makes it ideal for use in high-interference environments, such as data centers and industrial settings.


3.The jacket color of this LAN cable is gray, which makes it easy to identify and organize in a crowded networking environment. The cable length is 100m, which provides plenty of flexibility for installing your network infrastructure. The frequency range of this cable is up to 600MHz, which ensures that it can handle high-bandwidth applications with ease.


4.The conductor material of this cable is copper, which provides excellent conductivity and durability. Copper is a popular choice for networking cables because it is resistant to corrosion and can withstand high temperatures. The jacket material of this cable is PVC, which is a durable and flexible material that provides excellent protection against physical damage.


5.In conclusion, if you are looking for a high-performance, reliable, and durable networking solution for your home or office, this CAT7 SFTP 23AWG 600MHz CPR Dca-s2,d2,a1 Gray PVC High Speed Network Cable is an excellent choice. With its superior shielding, high-speed capabilities, and backward compatibility, this Cat7 Ethernet Cable is designed to meet the needs of even the most demanding networking environments.

Technical Parameters:

Cable TypeCAT7 Ethernet Cable, Cat 7 Lan Cable
Frequency600MHz
Length1000Ft
Jacket ColorGray
Conductor MaterialCopper
Conductor Size23AWG
Jacket MaterialPVC
Shielding TypeSFTP

Product Description:

CAT7 SFTP 23AWG 600MHz CPR Dca-s2,d2,a1 Gray PVC High Speed Network Cable

Rev.: AECN Description:
Construction Item DescriptionElectrical Property

Conductor


Material

Bare Solid Copper(elongation:

19-24%)

Conductor Resistance at 20°C≤ 9.5 Ω / 100m
OD23 AWGResistance unbalance within a pair≤ 2%

Insulation

MaterialPE Skin-Foam-SkinInsulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

>1500 MΩ / 100m

OD1.33 ±0.01 mmMutual capacitance5600 pF / 100m MAX
Average THK0.37mmCapacitance unbalance pair to ground at 800Hz or 1 kHz≤ 160 pF / 100m

Color

1p: white + 2 blue stripes & blueCharacteristic impedance at 100MHz100 ± 15 Ω

2p: white + 2 orange stripes &

orange

Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or

0.7 KV AC for 1 min


No breakdown

3p: white + 2 green stripes & greenMechanical Property
4p: white + 2 brown stripes & brown

insulation

elongation before aging≥ 300%

Pair Twist


Lay & Direction

1p: S=19.0 mm (28%)tensile strength before aging≥12 MPa
2p: S=23.5 mm (31%)elongation after aging≥ 150 %
3p: S=21.5 mm (33%)tensile strength after aging≥10.5 MPa
4p: S=25.0 mm (36%)

jacket

elongation before aging≥ 125 %
OD/tensile strength before aging≥ 10 MPa

Inner Assemble

LayS=90 ± 5 mmelongation after aging≥ 100 %
Directionaccording to the drawingtensile strength after aging≥ 8 MPa
OD/Packing

Filler

Ripcord3*250DDrumNA
Drain Wire/

Pair Shield

ShieldPair Shield
Construction/
MaterialPolyester/Aluminium (PET/ALU)
Coverage≥ 115%

Braid

Materialɸ 0.12mm Aluminum-magnesium braided
Coverage≥ 40%

Jacket

MaterialPVC, 60P, -20~75℃
Hardness81± 3
OD8.1 ± 0.2
Average THK0.55 ~ 0.65

Color

Gray
Marking Colorblack
Marking

according to the customer's

requirements


Electrical Properties
Conductor Resistance at 20°CNF EN 50289-1-2 / IEC 60189-1≤ 9.5 Ω / 100m
Resistance unbalance within a pairNF EN 50289-1-2/ IEC 60708≤ 2%

Dielectric Strength

Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min


NF EN 50289-1-3 / IEC 61196-1-105


No breakdown

Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

NF EN 50289-1-4 / IEC 60885-1

>1500 MΩ / 100m
Mutual capacitanceNF EN 50289-1-5 /IEC 60189-15600pF / 100m MAX
Capacitance unbalance pair to ground at 800Hz or 1 kHzNF EN 50289-1-5 / IEC 60189-1≤ 160 pF / 100m
Characteristic impedance at 100MHzNF EN 50289-1-11/ IEC 61156-1100 ± 15 Ω
Spark TestUL4442000 ± 250VOC

Transmission Properties
CAT7 ANSI/TIA-568.2-D; IEC 61156-6; YD/T1019-2013

No.


Frequency


Attenuation (Max)

Propagation Delay

(Max)

Propagation Delay Skew

(Max)


Return Loss (Min)


NEXT (Min)


PS NEXT (Min)


EL-FEXT (Min)


PS EL-FEXT (Min)

MHzdB/100mns/100mns/100mdB(on 100m)dB(on 100m)dB(on 100m)dB(on 100m)dB(on 100m)
143.745522523.0078.075.3078.075.00
285.245472524.5078.075.075.9072.90
3105.865452525.0078.075.074.0071.00
4167.415432525.0078.075.069.9066.90
5208.295422525.0078.075.068.0065.00
6259.295412524.3078.075.066.0063.00
731.2510.415402523.6078.075.064.1061.10
862.514.885392521.5075.5072.4055.1055.10
910019.205382520.1072.4069.4054.0051.00
1015023.565372518.9069.8066.8050.2047.20
1120027.745362518.0067.8064.9048.0045.00
1225030.975362517.3066.4063.4046.0043.00
1330034.195362517.3065.2062.2044.5041.50
1460050.105362517.3060.7057.7038.4035.40
1580058.925352517.3058.9055.9035.9032.90
16100066.935352517.1057.4054.4034.0031.00

Applications:

1.With a frequency rating of 600MHz, this CAT7 SFTP 23AWG 600MHz CPR Dca-s2,d2,a1 Gray PVC High Speed Network Cable is capable of handling even the most demanding applications. Whether you're streaming high-definition video, gaming online, or transferring large files in a home entertainment system, office network, or a data center where high-speed and stable connection is essential, this cable will provide you with the speed and reliability you need to get the job done.


2.One of the key features of this Cat 7 Ethernet Cable is its conductor size. At 23AWG, it is thicker than many other network cables, which allows it to transmit data more quickly and efficiently. Additionally, the conductor material is copper, which is known for its excellent conductivity and durability. This combination of 23AWG copper conductor and 600MHz frequency makes it highly suitable for applications that require rapid data transfer, such as in a busy office environment with multiple users accessing cloud services simultaneously or in a data center handling vast amounts of data traffic.


3.The jacket material of this Cat 7 Ethernet Cable is PVC, which provides excellent protection against damage from environmental factors such as moisture and temperature fluctuations. The gray color of the PVC jacket not only gives it a professional and sleek look but also makes it easy to identify and manage in a complex network setup. Its CPR compliance with Dca-s2,d2,a1 characteristics makes it an ideal choice for installation in buildings where fire safety regulations are strict, like commercial complexes and public institutions. It can also be used in industrial settings where reliable data transfer and resistance to harsh conditions are necessary.


4.Overall, the ITI-LINK CAT7 SFTP 23AWG 600MHz CPR Dca-s2,d2,a1 Gray PVC High Speed Network Cable is a versatile and reliable network cable that is well-suited for a variety of applications. Whether you're setting up a new network or upgrading an existing one in any of the aforementioned settings, this cable is an excellent choice that will provide you with the speed and performance you need to get the job done.


FAQ:

Q: What is the brand name of this product?

A: The brand name of this product is ITI-LINK.


Q: What is the model number of this product?

A: The model number of this product is ITI-CT7SF-007.


Q: Where is this product manufactured?

A: This product is manufactured in SHENZHEN.


Q: What is the maximum speed supported by this cable?

A: This cable supports a maximum speed of 10Gbps.


Q: Is this cable suitable for outdoor use?

A: No, this cable is not suitable for outdoor use as it is not waterproof or UV-resistant. It is recommended for indoor use only.

Buy 600MHz SFTP CAT7 Cable 23AWG CPR Dca-S2 D2 A1 Gray PVC High Speed Network Cable at wholesale prices
Send your message to this supplier
 
*From:
*To: Integrity Cable Co., Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0