| Sign In | Join Free | My benadorassociates.com |
|
| Categories | Aerial Bundled Cable |
|---|---|
| Model NO.: | ABC Cable |
| Material Shape: | Round Wire |
| Range of Application: | Overhead |
| Certification: | ISO9001, CE, SGS TUV |
| Brand: | Ume |
| Third Party Inspection: | Accepted |
| Sample: | Free |
| Printing: | Laser Printing , Hot Printing , Ink Printing |
| Warranty: | 24 Months |
| Transport Package: | Drum |
| Specification: | up to 336.4 AWG |
| Trademark: | UME |
| Origin: | China |
| HS Code: | 8544492100 |
| Supply Ability: | 7000km Per Month |
| Type: | Insulated |
| Conductor Type: | Stranded |
| Application: | Overhead, Construction Sites, Street Lighting |
| Conductor Material: | Aluminum, Aluminum and Steel, Aluminum Alloy |
| Sheath Material: | None |
| Insulation Material: | Bare, PE, XLPE, PVC |
| Samples: | US$ 2/Meter 1 Meter(Min.Order) | Request Samp |
| Company Info. |
| HENAN UME CABLE CO., LTD. |
| Verified Supplier |
| View Contact Details |
| Product List |
ONE-STOP SOLUTIONS FOR WIRES&CABLES - HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export
to over 50 countries.
1. Applications
Aerial Bundled Cable is primarily used for overhead service
applications such as construction sites, outdoor or street
lighting, etc.
Triplex Service Drop is used to supply power and is primarily used
for overhead service applications such as construction sites,
outdoor, or lighting. Usually from a pole-mounted transformer, to
the user's service head where connection to the service entrance
cable is made. To be used at voltages of 600V phase-to-phase or
less and at conductor temperatures not to exceed 75°C for
polyethylene insulated conductors or 90°C for cross-linked
polyethylene (XLPE) insulated conductors.
2. Specification
Triplex service drop cable meets or exceeds the following ASTM
specifications:
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel
Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
•ICEA S-76-474-Neutral-supported Power Cable Assemblies With
Weather-Resistant Extruded Insulation Rated 600VoltsStandards
3. Standards
Aerial Bundled Cable meets or exceeds the following international
standards: IEC, BS, DIN, ASTM, BS, and GB standards.
Specification
a. Duplex Service Drop
Application:To supply 120 volt aerial service for temporary service
at construction sites,outdoor or street lighting . For service at
600 volts or lower at a conductor temperature of 75°C maximum.
b. Triplex Service Drop
Application: To supply power from the utility's lines to the
consumer's weatherhead. For service at 600 volt or less (phase to
phase) at a conductor temperature of 75°C maximum for polyethylene
insulation 90°C maximum for crosslinked insulation.
c. Quadruplex Service Drop.
Used to supply 3 phase power, usually from a polemounted
transformer, to the user's service head where connection to the
service entrance cable is made. To be used at voltages of 600 volts
or less phase to phase and at conductor temperatures not to exceed
75°C for polyethylene insulation 90°C maximum for crosslinked
polyethylene(XLPE) insulated conductors.
| Phase Conductor | Aluminium conductor, round stranded compressed (RM). |
| Neutral Conductor | Alloy aluminium conductor (AlMgSi), round stranded compressed (RM). |
| Insulation | XLPE. Load-bearing / neutral core - marked with standard and producers phase core - marked with digits 1, 2, 3. |
| Assembly | Cores and the neutral, conductor stranded together in right-hand lay, additionally 1, 2 or 3 cores of reduced cross section can be co-stranded. |
| Rated voltage | kV | 0.6/1 |
| Test voltage | Veff kV/Hz | 4/50 |
| Laying temperature | °C | min. -5 |
| Operating temperature | °C | -30 ~ +90 |
| Conductor temperature | °C | max. +90 |
| Short-circuit temperature | °C/s | max. +250 /5 |
| Bending radius (min.) | mm | 20 × O of cable |
| Number of cores x nominal cross section | max. conductor- resistance | min. breaking load of conductor strand | Current rating in the air | Outer diameter | Total weight |
| mm^2 | Ohm/km | kN | A | mm | kg/km |
| 2x10 RM | 3.080 | 1.5 | 38 | 12.8 | 93 |
| 4x10 RM | 3.080 | 1.5 | 38 | 15.4 | 183 |
| 2x16 RM | 1.910 | 2.3 | 72 | 14.8 | 129 |
| 2x16 RN + 2x1.5 RE | 1.910/12.100 | 2.3 | 72 | 14.8 | 176 |
| 4x16 RM | 1.910 | 2.3 | 72 | 17.8 | 257 |
| 4x16 RN + 2x1.5 RE | 1.910/12.100 | 2.3 | 72 | 17.8 | 304 |
| 2x25 RM | 1.200 | 3.8 | 107 | 18.0 | 202 |
| 2x25 RM + 2x1,5 RE | 1.200/12.100 | 3.8 | 107 | 18.0 | 249 |
| 4x25 RM | 1.200 | 3.8 | 107 | 21.7 | 404 |
| 4x25 RM + 2x1,5 RE | 1.200/12.100 | 3.8 | 107 | 21.7 | 451 |
| 2x35 RM | 0.868 | 5.2 | 132 | 20.8 | 269 |
| 2x35 RM + 2x1,5 RE | 0.868/12.100 | 5.2 | 132 | 20.8 | 316 |
| 4x35 RM | 0.868 | 5.2 | 132 | 25.1 | 539 |
| 4x35 RM + 2x1,5 RE | 0.868/12.100 | 5.2 | 132 | 25.1 | 586 |
| 2x50 RM | 0.641 | 7.6 | 165 | 23.4 | 352 |
| 2x50 RM + 2x1,5 RE | 0.641/12.100 | 7.6 | 165 | 23.4 | 399 |
| 1x54.6 RM + 3x25 RM | 0.630/1.200 | 3.8 | 107 | 21.7 | 507 |
| 1x54.6 RM + 3x25 RM + 1x16 RM | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 | 24.3 | 573 |
| 1x54.6 RM + 3x25 RM + 2x16 RM | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 | 29.7 | 639 |
| 1x54.6 RM + 3x25 RM + 3x16 RM | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 | 31.1 | 705 |
| 1x54.6 RM + 3x35 RM | 0.630/0.868 | 5.2 | 132 | 25.1 | 615 |
| 1x54.6 RM + 3x35 RM + 1x16 RM | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 | 28.1 | 680 |
| 1x54.6 RM + 3x35 RM + 2x16 RM | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 | 34.3 | 748 |
| 1x54.6 RM + 3x35 RM + 3x16 RM | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 | 35.9 | 814 |
| 1x54.6 RM + 3x35 RM + 1x25 RM | 0.630/0.868/1.200 | 5.2/3.8 | 132/107 | 28.1 | 714 |
| 1x54.6 RM + 3x50 RM | 0.630/0.641 | 7.6 | 165 | 28.2 | 741 |
| 1x54.6 RM + 3x50 RM + 1x16 RM | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 | 31.6 | 806 |
| 1x54.6 RM + 3x50 RM + 2x16 RM | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 | 38.6 | 875 |
| 1x54.6 RM + 3x50 RM + 3x16 RM | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 | 40.4 | 940 |
| 1x54.6 RM + 3x50 RM + 1x25 RM | 0.630/0.641/1.200 | 7.6/3.8 | 165/107 | 31.6 | 841 |
| 1x54.6 RM + 3x70 RM | 0.630/0.443 | 10.2 | 205 | 33.0 | 950 |
| 1x54.6 RM + 3x70 RM + 1x16 RM | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 | 37.0 | 1014 |
| 1x54.6 RM + 3x70 RM + 2x16 RM | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 | 45.2 | 1083 |
| 1x54.6 RM + 3x70 RM + 3x16 RM | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 | 47.3 | 1148 |
| 1x54.6 RM + 3x70 RM + 1x25 RM | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 | 37.0 | 1048 |
| 1x54.6 RM + 3x70 RM + 2x25 RM | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 | 45.2 | 1150 |
| 1x54.6 RM + 3x70 RM + 3x25 RM | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 | 47.3 | 1250 |
| 1x54.6 RM + 3x95 RM | 0.630/0.320 | 13.5 | 240 | 37.4 | 1176 |
| 1x54.6 RM + 3x95 RM + 1x16 RM | 0.630/0.320/1.910 | 13.5/2.3 | 240/72 | 41.9 | 1243 |



HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!
Production:






|